EXPERIMENTAL STUDIES OF ROTATION EFFICIENCY OF PACKING ON CHARACTERISTICS OF COUNTER FLOW WET COOLING TOWER

被引:0
|
作者
Teimoori, Khashayar [1 ]
Sadegh, Ali M. [1 ]
机构
[1] CUNY City Coll, Dept Mech Engn, Ctr Adv Engn Design & Dev, New York, NY 10031 USA
关键词
Experimental Method; Wet Cooling Tower; Counter flow; Rotational Packing; PERFORMANCE;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Packing in cooling towers is commonly used in nuclear power plants and air conditioning systems. However their efficiency with respect to the inlet air flow rate and the temperature of the water has not been fully investigated. In this research, the efficiency of packing rotational speed with respect to the,wet counter flow of a cooling tower is experimentally investigated. In our experimental studies, six elliptical wooden plates that are equally spaced are used as a packing tower. The packing area of 0.85 m(2) is considered with the following rotor speed ranges: 0.5, 3.5, 10, 15 and 17 rpm. It is assumed that the water mass flow rate is proportional to the inlet air to the tower. Six mass flow rates starting from 0.2 to 2.8 kg/h and the inlet air and water temperatures of 27 degrees C and 45 degrees C, respectively, are considered. The results illustrate that for the range of 0 to 5 rpm of the packing rotational speed the cooling rate of water is increased 3% for the water flow rate of 2.8 kg/h, and 24% for the water flow rate of 0.4 kg/h. Additionally, as a result of the increased rotational speed from 5 to over 17 rpm the cooling rate at both maximum and minimum water mass flow rates are increased from 13.9 to 34.4 percent, respectively. Furthermore, the water outlet temperature is reduced from 8.6 degrees C to 3.3 degrees C in the least and the most mass flow rates leading to the increased speed from 5 to 17 rpm, respectively. The experimental relationship between the inlet air temperature and the rotational speed of the packing has been determined. Also, the inlet water temperature at the maximum flow rate has been decreased to 3.4 and at the least water mass flow rate it has been decreased to 29 percent for the range of rotational speed from 5 to over 17 rpm of the packing rotation. All the results are depicted in several curves to show the actual variations of the variables.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] The Effect of the Air Water Ratio on Counter Flow Cooling Tower
    Liu, Nailing
    Zhang, Lixia
    Jia, Xiangqin
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3550 - 3556
  • [42] Performance Assessment of a Counter Flow Cooling Tower - Unique Approach
    Naik, B. Kiran
    Choudhary, V.
    Muthukumar, P.
    Somayaji, C.
    INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENT IN AIR CONDITIONING AND REFRIGERATION, RAAR 2016, 2017, 109 : 243 - 252
  • [43] EXPERIMENTAL AND NUMERICAL ANALYSIS OF THE FORCED DRAFT WET COOLING TOWER
    Lafta, Noor Samir
    Kareem, Fadhil Abdulrazzaq
    Ghafur, Maha H.
    JOURNAL OF THERMAL ENGINEERING, 2023, 9 (01):
  • [44] Experimental and numerical analysis of the forced draft wet cooling tower
    Lafta, Noor Samir
    Kareem, Fadhil Abdulrazzaq
    Ghafur, Maha
    JOURNAL OF THERMAL ENGINEERING, 2023, 9 (02): : 518 - 529
  • [45] Research on heat and mass transfer characteristics of a counterflow wet cooling tower using a new type of straight wave packing
    Xi, Ying
    Yu, Zhikang
    Zhang, Lin
    Yu, Aimei
    Liu, Lei
    Bao, Bingguo
    Zhao, Youchang
    Zhou, Chengman
    Wu, Bingjie
    Dong, Kexin
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 193
  • [46] Performance analysis of a counter flow wet cooling tower and selection of optimum operative condition by MCDM-TOPSIS method
    Keshtkar, Mohammad Mehdi
    APPLIED THERMAL ENGINEERING, 2017, 114 : 776 - 784
  • [47] Energy Efficiency in an Industrial Wet Cooling Tower Through Improved Control
    Marques, Celso A. X.
    Fontes, Cristiano H.
    Embirucu, Marcelo
    Kalid, Ricardo A.
    10TH INTERNATIONAL SYMPOSIUM ON PROCESS SYSTEMS ENGINEERING, 2009, 27 : 1449 - 1454
  • [48] Theoretical analysis of heat and mass transfer characteristics of a counter-flow packing tower with different heating modes
    Chen, Liang
    Yu, Jing
    Fang, Xueyou
    Zhen, Shucong
    Jin, Sumin
    APPLIED THERMAL ENGINEERING, 2025, 258
  • [49] Experimental study of cooling tower performance using ceramic tile packing
    Ramkrishnan, Ramkumar
    Arumugam, Ragupathy
    PROCESSING AND APPLICATION OF CERAMICS, 2013, 7 (01) : 21 - 27
  • [50] Analysis of the Effect of Packing Materials (Fills) and Flow Rate on the Range and Efficiency of a Forced Draft Evaporative Cooling Tower
    Shinde, Swapnil S.
    Gulhane, Nitin P.
    Taler, Jan
    Oclon, Pawel
    Taler, Dawid
    Vollaro, Roberto de Lieto
    ENERGIES, 2023, 16 (14)