The investigation of interferences in immunoassay

被引:111
作者
Ward, Greg [1 ]
Simpson, Aaron [2 ,4 ]
Boscato, Lyn [3 ]
Hickman, Peter E. [2 ,4 ]
机构
[1] Sullivan Nicolaides Pathol, Dept Biochem, 24 Hurworth St, Bowen Hills, Qld 4006, Australia
[2] Canberra Hosp, Dept Chem Pathol, Canberra, ACT 2605, Australia
[3] SydPath, Dept Chem Pathol, Darlinghurst, NSW 2010, Australia
[4] Australian Natl Univ, Med Sch, Canberra, ACT 2601, Australia
关键词
Immunoassay interference; Heterophile; High-dose hook; Artifactual results; THYROID-STIMULATING HORMONE; CARDIAC TROPONIN-I; ANTIBODY INTERFERENCE; GRAVES-DISEASE; MACRO-TSH; SERUM; AUTOANTIBODIES; BIOTIN; ASSAYS; PROLACTIN;
D O I
10.1016/j.clinbiochem.2017.08.015
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Immunoassay procedures have a wide application in clinical medicine and as such are used throughout clinical biochemistry laboratories both for urgent and routine testing. Clinicians and laboratory personnel are often presented with immunoassay results which are inconsistent with clinical findings. Without a high index of suspicion interferences will often not be suspected. Artifactual results can be due to a range of interferences in immunoassays which can include cross reacting substances, heterophile antibodies, autoantibodies and the high dose hook effect. Further, pre-analytical aspects and certain disease states can influence the potential for interference in immunoassays. Practical solutions for investigation of artifactual results in the setting of the routine clinical laboratory are provided.
引用
收藏
页码:1306 / 1311
页数:6
相关论文
共 62 条
[1]   Circulating Cardiac Troponin-I Autoantibodies in Human Plasma and Serum [J].
Adamczyk, Maciej ;
Brashear, R. Jeffrey ;
Mattingly, Phillip G. .
CONTEMPORARY CHALLENGES IN AUTOIMMUNITY, 2009, 1173 :67-74
[2]  
ANDERSEN AN, 1982, FERTIL STERIL, V38, P625
[3]   Cyclosporin: revisions in monitoring guidelines and review of current analytical methods [J].
Andrews, D ;
Cramb, R .
ANNALS OF CLINICAL BIOCHEMISTRY, 2002, 39 :424-435
[4]  
BLACKBURN GF, 1991, CLIN CHEM, V37, P1534
[5]  
Bohner J, 1996, CLIN CHEM, V42, P2046
[6]   Heterophilic antibody interference in immunometric assays [J].
Bolstad, Nils ;
Warren, David J. ;
Nustad, Kjell .
BEST PRACTICE & RESEARCH CLINICAL ENDOCRINOLOGY & METABOLISM, 2013, 27 (05) :647-661
[7]   Reason for limitations of heterophilic blocking tube use on certain Beckman Coulter access assays [J].
Cantor, D .
CLINICAL CHEMISTRY, 2005, 51 (07) :1311-1311
[8]   PREGNANCY TESTS - A REVIEW [J].
CHARD, T .
HUMAN REPRODUCTION, 1992, 7 (05) :701-710
[9]   Biotin IgM Antibodies in Human Blood: A Previously Unknown Factor Eliciting False Results in Biotinylation-Based Immunoassays [J].
Chen, Tingting ;
Hedman, Lea ;
Mattila, Petri S. ;
Jartti, Laura ;
Jartti, Tuomas ;
Ruuskanen, Olli ;
Soderlund-Venermo, Maria ;
Hedman, Klaus .
PLOS ONE, 2012, 7 (08)
[10]  
Dasgupta A, 1999, AM J CLIN PATHOL, V112, P753