Biomechanical 3-Dimensional Finite Element Analysis of Obturator Protheses Retained with Zygomatic and Dental Implants in Maxillary Defects

被引:0
|
作者
Akay, Canan [1 ]
Yalug, Suat [2 ]
机构
[1] Prosthodontist, Private Practice, Ankara, Turkey
[2] Gazi Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
来源
MEDICAL SCIENCE MONITOR | 2015年 / 21卷
关键词
Finite Element Analysis; Palatal Obturators; Prostheses and Implants; PARTIALLY EDENTULOUS PATIENTS; PROSTHETIC REHABILITATION; BASIC PRINCIPLES; RECONSTRUCTION; OVERDENTURES; DESIGN;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The objective of this study was to investigate the stress distribution in the bone around zygomatic and dental implants for 3 different implant-retained obturator prostheses designs in a Aramany class IV maxillary defect using 3-dimensional finite element analysis (FEA). Material\Methods: A 3-dimensional finite element model of an Aramany class IV defect was created. Three different implant-retained obturator prostheses were modeled: model 1 with 1 zygomatic implant and 1 dental implant, model 2 with 1 zygomatic implant and 2 dental implants, and model 3 with 2 zygomatic implants. Locator attachments were used as a superstructure. A 150-N load was applied 3 different ways. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis are expressed in MPa. Results: In all loading conditions, model 3 (when compared models 1 and 2) showed the lowest maximum principal stress value. Model 3 is the most appropirate reconstruction in Aramany class IV maxillary defects. Two zygomatic implants can reduce the stresses in model 3. The distribution of stresses on prostheses were more rational with the help of zygoma implants, which can distribute the stresses on each part of the maxilla. Conclusions: Aramany class IV obturator prosthesis placement of 2 zygomatic implants in each side of the maxilla is more advantageous than placement of dental implants. In the non-defective side, increasing the number of dental implants is not as suitable as zygomatic implants.
引用
收藏
页码:604 / 611
页数:8
相关论文
共 50 条
  • [31] UNDERSTANDING THE BIOMECHANICAL RESPONSE OF PROGRESSIVE THREAD DENTAL IMPLANTS USING MULTI-SCALE FINITE ELEMENT ANALYSIS
    Chakraborty, Arindam
    Sahare, Kalash Darshan
    Majumder, Santanu
    Chowdhury, Amit Roy
    INTERNATIONAL JOURNAL FOR MULTISCALE COMPUTATIONAL ENGINEERING, 2024, 22 (04) : 31 - 44
  • [32] 3-dimensional finite element analysis of a vibrating bellows with a large diameter
    Kim, Jae-Hyun
    Kim, Jung-Yup
    Jang, Bongkyun
    Kim, Kyung-Shik
    Choi, Byung-Ik
    Jun, Sang-Hyun
    Kim, Jun-Ho
    ADVANCES IN FRACTURE AND DAMAGE MECHANICS IX, 2011, 452-453 : 689 - 692
  • [33] Effects of custom-made and thread dental implant systems on the stress distribution in alveolar bone: a 3-dimensional finite element analysis
    Zhang, Xiao
    Xie, Zhangong
    Feng, Wei
    Chen, Xianshuai
    Chen, Jianyu
    SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS II, PTS 1 AND 2, 2014, 475-476 : 1487 - +
  • [34] All-on-4 Concept: A 3-Dimensional Finite Element Analysis
    Sannino, Gianpaolo
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (02) : 163 - 171
  • [35] Biomechanical Design Application on the Effect of Different Occlusion Conditions on Dental Implants with Different Positions-A Finite Element Analysis
    Lin, Pei-Ju
    Su, Kuo-Chih
    APPLIED SCIENCES-BASEL, 2020, 10 (17):
  • [36] Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis
    Tada, S
    Stegaroiu, R
    Kitamura, E
    Miyakawa, O
    Kusakari, H
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (03) : 357 - 368
  • [37] Mechanical response comparison in an implant overdenture retained by ball attachments on conventional regular and mini dental implants: a finite element analysis
    Chang, Shih-Hao
    Huang, Shiang-Rung
    Huang, Shao-Fu
    Lin, Chun-Li
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (08) : 911 - 921
  • [38] Biomechanics of the mandible: Part II. Development of a 3-dimensional finite element model to study mandibular functional deformation in subjects treated with dental implants
    Al-Sukhun, Jehad
    Kelleway, John
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (03) : 455 - 466
  • [39] Biomechanical influence of narrow-diameter implants placed at the crestal and subcrestal level in the maxillary anterior region. A 3D finite element analysis
    Cruz, Ronaldo S.
    Fernandes e Oliveira, Hiskell Francine
    Lemos, Cleidiel Aparecido Araujo
    Batista, Victor Eduardo de Souza
    da Silva, Rodrigo Capalbo
    Verri, Fellippo R.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (02): : 180 - 187
  • [40] Titanium versus magnesium plates for unilateral mandibular angle fracture fixation: biomechanical evaluation using 3-dimensional finite element analysis
    Prasadh, Somasundaram
    Krishnan, Anirudh Venkatraman
    Lim, C. Y. H.
    Gupta, Manoj
    Wong, Raymond
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2022, 18 : 2064 - 2076