PURPOSE: To evaluate the feasibility of reconstructing single and multiple targets by using fluorescence-enhanced tomography of a breast tissue phantom. MATERIALS AND METHODS: Frequency-domain fluorescence measurements were performed in cup-shaped tissue phantoms of clinically relevant size (diameter, 10 cm) in which single or multiple 0.5-1.0-cm(3) targets that contained micromolar concentrations of indocyanine green with 1:0 and 100:1 target-to-background (T:B) contrast ratios had been embedded. Rapid acquisition of time-dependent fluorescent light measurements was performed at the phantom surface in response to point illumination of excitation light by using a gain-modulated intensified charge-coupled device detection system. Boundary surface measurements were used to tomographically reconstruct the interior targets located with various experimental conditions. RESULTS: Single 1.0-cm(3) targets located between 1.43 and 2.82 cm deep from the phantom surface at a T:B contrast ratio of 100:1 and three approximately 0.55-cm(3) targets located about 1.30 cm deep at a T:B contrast ratio of 1:0 were reconstructed with minimal or no artifacts by using boundary surface fluorescence measurements and an approximate extended Kalman filter algorithm. CONCLUSION: It is feasible to detect single or multiple fluorescent targets in tissue phantoms of clinically relevant size by using fluorescence-enhanced optical tomography. (C) RSNA, 2005.
引用
收藏
页码:148 / 154
页数:7
相关论文
共 22 条
[1]   Optical-based molecular imaging: contrast agents and potential medical applications [J].
Bremer, C ;
Ntziachristos, V ;
Weissleder, R .
EUROPEAN RADIOLOGY, 2003, 13 (02) :231-243
[2]   Three-dimensional, Bayesian image reconstruction from sparse and noisy data sets: Near-infrared fluorescence tomography [J].
Eppstein, MJ ;
Hawrysz, DJ ;
Godavarty, A ;
Sevick-Muraca, EM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (15) :9619-9624
[3]   Three-dimensional Bayesian optical image reconstruction with domain decomposition [J].
Eppstein, MJ ;
Dougherty, DE ;
Hawrysz, DJ ;
Sevick-Muraca, EM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (03) :147-163
[4]   Coupled complex adjoint sensitivities for frequency-domain fluorescence tomography: theory and vectorized implementation [J].
Fedele, F ;
Laible, JP ;
Eppstein, MJ .
JOURNAL OF COMPUTATIONAL PHYSICS, 2003, 187 (02) :597-619
[5]   Fluorescence-enhanced optical imaging in large tissue volumes using a gain-modulated ICCD camera [J].
Godavarty, A ;
Eppstein, MJ ;
Zhang, CY ;
Theru, S ;
Thompson, AB ;
Gurfinkel, M ;
Sevick-Muraca, EM .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (12) :1701-1720
[6]   Error consideration in contrast-enhanced three-dimensional optical tomography [J].
Hawrysz, DJ ;
Eppstein, MJ ;
Lee, JW ;
Sevick-Muraca, EM .
OPTICS LETTERS, 2001, 26 (10) :704-706
[7]  
Houston JP, 2003, PHOTOCHEM PHOTOBIOL, V77, P420, DOI 10.1562/0031-8655(2003)077<0420:SADPOC>2.0.CO
[8]  
2
[9]   FLUORESCENCE LIFETIME-BASED SENSING IN TISSUES - A COMPUTATIONAL STUDY [J].
HUTCHINSON, CL ;
LAKOWICZ, JR ;
SEVICKMURACA, EM .
BIOPHYSICAL JOURNAL, 1995, 68 (04) :1574-1582
[10]  
KOGURE K, 1970, ARCH OPHTHALMOL-CHIC, V83, P209