Optimizing detector geometry for trace element mapping by X-ray fluorescence

被引:28
作者
Sun, Yue [1 ]
Gleber, Sophie-Charlotte [2 ]
Jacobsen, Chris [2 ,4 ,5 ]
Kirz, Janos [3 ]
Vogt, Stefan [2 ]
机构
[1] Northwestern Univ, Grad Program Appl Phys, Evanston, IL 60208 USA
[2] Argonne Natl Lab, Argonne, IL 60439 USA
[3] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
[4] Northwestern Univ, Dept Phys & Astron, Evanston, IL 60208 USA
[5] Northwestern Univ, Chem Life Proc Inst, Evanston, IL 60208 USA
基金
美国国家卫生研究院;
关键词
Trace element detection; X-ray fluorescence; X-ray fluorescence microscopy; Detector geometry; Signal-to-noise ratio; MONTE-CARLO-SIMULATION; HOMOGENEOUS SAMPLES; SYNCHROTRON-RADIATION; BIOLOGICAL-MATERIALS; FREE-ELECTRONS; SOLAR-CELLS; SCATTERING; SPECTROMETERS; MICROSCOPY; PIXE;
D O I
10.1016/j.ultramic.2014.12.014
中图分类号
TH742 [显微镜];
学科分类号
摘要
Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90 degrees to the beam versus a larger detector at 180 degrees (in a backscatter-like geometry), the 90 degrees detector is better for trace element detection in thick samples, while the larger detector in 180 degrees geometry is better suited to trace element detection in thin samples. (C) 2015 Published by Elsevier B.V.
引用
收藏
页码:44 / 56
页数:13
相关论文
共 50 条
[41]   Elemental mapping of biofortified wheat grains using micro X-ray fluorescence [J].
Ramos, I. ;
Pataco, I. M. ;
Mourinho, M. P. ;
Lidon, F. ;
Reboredo, F. ;
Pessoa, M. F. ;
Carvalho, M. L. ;
Santos, J. P. ;
Guerra, M. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 120 :30-36
[42]   Calcium element quantification model using a portable X-ray fluorescence unit [J].
Gonzalez-Rojas, Claudio H. ;
Castro-Rodriguez, Cristian ;
Gutierrez-Vivancoa, Sebastian ;
Vargas-Verab, Esteban .
METHODSX, 2023, 11
[43]   Development of Portable X-Ray Diffractometer Equipped with X-Ray Fluorescence Spectrometer and Its Application to Archaeology [J].
Yamashita, Daisuke ;
Ishizaki, Atsushi ;
Uda, Masayuki .
BUNSEKI KAGAKU, 2009, 58 (05) :347-355
[44]   High resolution X-ray fluorescence measurements using a flat analyzer crystal and an X-ray CCD [J].
Hayakawa, S ;
Kagoshima, Y ;
Tsusaka, Y ;
Matsui, J ;
Hirokawa, T .
JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 2001, 19 (04) :615-621
[45]   Dual-detector X-ray fluorescence imaging of ancient artifacts with surface relief [J].
Smilgies, Detlef-M. ;
Powers, Judson A. ;
Bilderback, Donald H. ;
Thorne, Robert E. .
JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 :547-550
[46]   Total-reflection X-ray fluorescence studies of trace elements in biomedical samples [J].
Kubala-Kukus, A ;
Braziewicz, J ;
Pajek, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (08) :1283-1289
[47]   Comparison of X-ray fluorescence and optical fluorescence measured behind scattering layers as a basis for X-ray fluorescence endoscopy [J].
Beuthan, J ;
Haschke, M ;
Dressler, C ;
Wacker, F .
BIOMEDIZINISCHE TECHNIK, 2005, 50 (03) :54-59
[48]   Total-reflection X-ray fluorescence imaging [J].
Sakurai, K .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (10) :1497-1503
[49]   X-ray fluorescence microtomography with a Wolter mirror system [J].
Watanabe, N ;
Yamamoto, K ;
Takano, H ;
Ohigashi, T ;
Yokosuka, H ;
Aota, T ;
Aoki, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 :837-840
[50]   Techniques for depth heterogeneity identification in X-ray fluorescence [J].
Trojek, T. ;
Cechak, T. ;
Mtisilek, L. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 263 (01) :76-78