Optimizing detector geometry for trace element mapping by X-ray fluorescence

被引:28
作者
Sun, Yue [1 ]
Gleber, Sophie-Charlotte [2 ]
Jacobsen, Chris [2 ,4 ,5 ]
Kirz, Janos [3 ]
Vogt, Stefan [2 ]
机构
[1] Northwestern Univ, Grad Program Appl Phys, Evanston, IL 60208 USA
[2] Argonne Natl Lab, Argonne, IL 60439 USA
[3] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
[4] Northwestern Univ, Dept Phys & Astron, Evanston, IL 60208 USA
[5] Northwestern Univ, Chem Life Proc Inst, Evanston, IL 60208 USA
基金
美国国家卫生研究院;
关键词
Trace element detection; X-ray fluorescence; X-ray fluorescence microscopy; Detector geometry; Signal-to-noise ratio; MONTE-CARLO-SIMULATION; HOMOGENEOUS SAMPLES; SYNCHROTRON-RADIATION; BIOLOGICAL-MATERIALS; FREE-ELECTRONS; SOLAR-CELLS; SCATTERING; SPECTROMETERS; MICROSCOPY; PIXE;
D O I
10.1016/j.ultramic.2014.12.014
中图分类号
TH742 [显微镜];
学科分类号
摘要
Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90 degrees to the beam versus a larger detector at 180 degrees (in a backscatter-like geometry), the 90 degrees detector is better for trace element detection in thick samples, while the larger detector in 180 degrees geometry is better suited to trace element detection in thin samples. (C) 2015 Published by Elsevier B.V.
引用
收藏
页码:44 / 56
页数:13
相关论文
共 50 条
[31]   A novel portable energy dispersive X-ray fluorescence spectrometer with triaxial geometry [J].
Pessanha, S. ;
Alves, M. ;
Sampaio, J. M. ;
Santos, J. P. ;
Carvalho, M. L. ;
Guerra, M. .
JOURNAL OF INSTRUMENTATION, 2017, 12
[32]   Attempt at two-dimensional mapping of X-ray fluorescence from breast cancer tissue [J].
Ando, M ;
Yamasaki, K ;
Ohbayashi, C ;
Esumi, H ;
Hyodo, K ;
Sugiyama, H ;
Li, G ;
Maksimenko, A ;
Kawai, T .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2005, 44 (28-32) :L998-L1001
[33]   X-ray fluorescence holography [J].
Faigel, G ;
Tegze, M ;
Marchesini, S ;
Belakhovsky, M .
JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2001, 114 :1063-1068
[34]   Analysis of trace Co in synthetic diamonds using synchrotron radiation excited X-ray fluorescence analysis [J].
Hayakawa, S ;
Jia, XP ;
Wakatsuki, M ;
Gohshi, Y ;
Hirokawa, T .
JOURNAL OF CRYSTAL GROWTH, 2000, 210 (1-3) :388-394
[35]   M-BLANK: a program for the fitting of X-ray fluorescence spectra [J].
Crawford, Andrew M. ;
Deb, Aniruddha ;
Penner-Hahn, James E. .
JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 (02) :497-503
[36]   X-ray scattering in X-ray fluorescence spectra with X-ray monochromatic, polarised excitation - Modelling, experiment, and Monte-Carlo simulation [J].
Hodoroaba, V. -D. ;
Radtke, M. ;
Reinholz, U. ;
Riesemeier, H. ;
Vincze, L. ;
Reuter, D. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (13) :1493-1498
[37]   A Monte Carlo study of x-ray fluorescence in x-ray detectors [J].
Boone, JM ;
Seibert, JA ;
Sabol, JM ;
Tecotzky, M .
MEDICAL PHYSICS, 1999, 26 (06) :905-916
[38]   Polarization X-Ray Fluorescence Analysis by Milliwatt X-ray Tube [J].
Kawai, Jun ;
Kato, Toshihide ;
Imashuku, Susumu .
TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2024, 110 (12) :981-987
[39]   Trace element mapping of a single cell using a hard x-ray nanobeam focused by a Kirkpatrick-Baez mirror system [J].
Matsuyama, S. ;
Shimura, M. ;
Mirnura, H. ;
Fujii, M. ;
Yumoto, H. ;
Sano, Y. ;
Yabashi, M. ;
Nishino, Y. ;
Tamasaku, K. ;
Ishikawa, T. ;
Yamauchi, K. .
X-RAY SPECTROMETRY, 2009, 38 (02) :89-94
[40]   Laboratory μ-X-ray fluorescence elemental mapping of herbarium specimens for hyperaccumulator studies [J].
van der Ent, Antony ;
Casey, Lachlan W. ;
Purwadi, Imam ;
Erskine, Peter D. .
PLANT AND SOIL, 2023, 493 (1-2) :663-671