Optimizing detector geometry for trace element mapping by X-ray fluorescence

被引:28
作者
Sun, Yue [1 ]
Gleber, Sophie-Charlotte [2 ]
Jacobsen, Chris [2 ,4 ,5 ]
Kirz, Janos [3 ]
Vogt, Stefan [2 ]
机构
[1] Northwestern Univ, Grad Program Appl Phys, Evanston, IL 60208 USA
[2] Argonne Natl Lab, Argonne, IL 60439 USA
[3] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
[4] Northwestern Univ, Dept Phys & Astron, Evanston, IL 60208 USA
[5] Northwestern Univ, Chem Life Proc Inst, Evanston, IL 60208 USA
基金
美国国家卫生研究院;
关键词
Trace element detection; X-ray fluorescence; X-ray fluorescence microscopy; Detector geometry; Signal-to-noise ratio; MONTE-CARLO-SIMULATION; HOMOGENEOUS SAMPLES; SYNCHROTRON-RADIATION; BIOLOGICAL-MATERIALS; FREE-ELECTRONS; SOLAR-CELLS; SCATTERING; SPECTROMETERS; MICROSCOPY; PIXE;
D O I
10.1016/j.ultramic.2014.12.014
中图分类号
TH742 [显微镜];
学科分类号
摘要
Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90 degrees to the beam versus a larger detector at 180 degrees (in a backscatter-like geometry), the 90 degrees detector is better for trace element detection in thick samples, while the larger detector in 180 degrees geometry is better suited to trace element detection in thin samples. (C) 2015 Published by Elsevier B.V.
引用
收藏
页码:44 / 56
页数:13
相关论文
共 50 条
  • [11] Quantified, multi-scale X-ray fluorescence element mapping using the Maia detector array: application to mineral deposit studies
    Fisher, Louise A.
    Fougerouse, Denis
    Cleverley, James S.
    Ryan, Christopher G.
    Micklethwaite, Steven
    Halfpenny, Angela
    Hough, Robert M.
    Gee, Mary
    Paterson, David
    Howard, Daryl L.
    Spiers, Kathryn
    MINERALIUM DEPOSITA, 2015, 50 (06) : 665 - 674
  • [12] Quantified, multi-scale X-ray fluorescence element mapping using the Maia detector array: application to mineral deposit studies
    Louise A. Fisher
    Denis Fougerouse
    James S. Cleverley
    Christopher G. Ryan
    Steven Micklethwaite
    Angela Halfpenny
    Robert M. Hough
    Mary Gee
    David Paterson
    Daryl L. Howard
    Kathryn Spiers
    Mineralium Deposita, 2015, 50 : 665 - 674
  • [13] X-ray scattering in X-ray fluorescence spectra with X-ray tube excitation - Modelling, experiment, and Monte-Carlo simulation
    Hodoroaba, V. -D.
    Radtke, M.
    Vincze, L.
    Rackwitz, V.
    Reuter, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (24) : 3568 - 3575
  • [14] Magnetic signature and X-ray fluorescence for mapping trace elements in soils originating from basalt and sandstone
    de Deus Ferreira e Silva J.
    Júnior J.M.
    Vieira da Silva L.F.
    Chitlhango A.P.
    Silva L.S.
    De Bortoli Teixeira D.
    Moitinho M.R.
    Fernandes K.
    Ferracciú Alleoni L.R.
    Chemosphere, 2023, 341
  • [15] Validation of the Geant4 Monte Carlo package for X-ray fluorescence spectroscopy in triaxial geometry
    Amaro, Pedro
    Santos, Jose Paulo
    Samouco, Ana
    Adao, Ricardo
    Martins, Luis Souto
    Weber, Sebastian
    Tashenov, Stanislav
    Carvalho, Maria Luisa
    Pessanha, Sofia
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 130 : 60 - 66
  • [16] X-ray fluorescence imaging
    Lider, V. V.
    PHYSICS-USPEKHI, 2018, 61 (10) : 980 - 999
  • [17] X-ray fluorescence and X-ray transmission microtomography imaging system
    Pereira, Gabriela R.
    Rocha, Henrique S.
    Anjos, Marcelino J.
    Faria, Paulo
    Perez, Carlos A.
    Lopes, Ricardo T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2) : 128 - 132
  • [18] An inclined detector geometry for improved X-ray total scattering measurements
    Burns, Nicholas
    Rahemtulla, Aly
    Annett, Scott
    Moreno, Beatriz
    Kycia, Stefan
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2023, 56 (Pt 2) : 510 - 518
  • [19] Quantifying X-Ray Fluorescence Data Using MAPS
    Nietzold, Tara
    West, Bradley M.
    Stuckelberger, Michael
    Lai, Barry
    Vogt, Stefan
    Bertoni, Mariana I.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (132):
  • [20] X-ray fluorescence analysis of trace elements in Mazi mountain ore
    Budak, G
    Karabulut, A
    Dogan, O
    Levent, M
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 1999, 17 (03): : 309 - 314