Optimizing detector geometry for trace element mapping by X-ray fluorescence

被引:28
|
作者
Sun, Yue [1 ]
Gleber, Sophie-Charlotte [2 ]
Jacobsen, Chris [2 ,4 ,5 ]
Kirz, Janos [3 ]
Vogt, Stefan [2 ]
机构
[1] Northwestern Univ, Grad Program Appl Phys, Evanston, IL 60208 USA
[2] Argonne Natl Lab, Argonne, IL 60439 USA
[3] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
[4] Northwestern Univ, Dept Phys & Astron, Evanston, IL 60208 USA
[5] Northwestern Univ, Chem Life Proc Inst, Evanston, IL 60208 USA
基金
美国国家卫生研究院;
关键词
Trace element detection; X-ray fluorescence; X-ray fluorescence microscopy; Detector geometry; Signal-to-noise ratio; MONTE-CARLO-SIMULATION; HOMOGENEOUS SAMPLES; SYNCHROTRON-RADIATION; BIOLOGICAL-MATERIALS; FREE-ELECTRONS; SOLAR-CELLS; SCATTERING; SPECTROMETERS; MICROSCOPY; PIXE;
D O I
10.1016/j.ultramic.2014.12.014
中图分类号
TH742 [显微镜];
学科分类号
摘要
Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90 degrees to the beam versus a larger detector at 180 degrees (in a backscatter-like geometry), the 90 degrees detector is better for trace element detection in thick samples, while the larger detector in 180 degrees geometry is better suited to trace element detection in thin samples. (C) 2015 Published by Elsevier B.V.
引用
收藏
页码:44 / 56
页数:13
相关论文
共 50 条
  • [1] Medical applications of X-ray fluorescence for trace element research
    Borjesson, Jimmy
    Mattsson, Soren
    POWDER DIFFRACTION, 2007, 22 (02) : 130 - 137
  • [2] TRACE ELEMENT QUANTIFICATION USING SYNCHROTRON RADIATION X-RAY FLUORESCENCE ANALYSIS
    Hayakawa, Shinjiro
    Iida, Atsuo
    Gohshi, Yohichi
    ANALYTICAL SCIENCES, 1991, 7 : 509 - 512
  • [3] X-ray fluorescence mapping of brain tissue reveals the profound extent of trace element dysregulation in stroke pathophysiology
    Pushie, M. Jake
    Sylvain, Nicole J.
    Hou, Huishu
    Pendleton, Nicole
    Wang, Richard
    Zimmermann, Liam
    Pally, Maxwell
    Cayabyab, Francisco S.
    Peeling, Lissa
    Kelly, Michael E.
    METALLOMICS, 2024, 16 (12)
  • [4] Simultaneous X-ray diffraction, crystallography and fluorescence mapping using the Maia detector
    Kirkwood, Henry J.
    de Jonge, Martin D.
    Muransky, Ondrej
    Hofmann, Felix
    Howard, Daryl L.
    Ryan, Chris G.
    van Riessen, Grant
    Rowles, Matthew R.
    Paradowska, Anna M.
    Abbey, Brian
    ACTA MATERIALIA, 2018, 144 : 1 - 10
  • [5] Total reflection X-ray fluorescence: A technique for trace element analysis in materials
    Misra, NL
    Mudher, KDS
    PROGRESS IN CRYSTAL GROWTH AND CHARACTERIZATION OF MATERIALS, 2002, 45 (1-2) : 65 - 74
  • [6] A Novel Detector Geometry for X-Ray CT
    Hsieh, Jiang
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (05) : 453 - 458
  • [7] Energy-dispersive X-ray diffraction mapping on a benchtop X-ray fluorescence system
    Lane, David W.
    Nyombi, Antony
    Shackel, James
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2014, 47 : 488 - 494
  • [8] Measurement of trace element levels in Kenyan cigarettes with the energy dispersive X-ray fluorescence spectroscopy technique
    Angeyo, KH
    Patel, JP
    Mangala, JM
    Narayana, DGS
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 1998, 16 (02): : 233 - 246
  • [9] Accurate determination of segmented X-ray detector geometry
    Yefanov, Oleksandr
    Mariani, Valerio
    Gati, Cornelius
    White, Thomas A.
    Chapman, Henry N.
    Barty, Anton
    OPTICS EXPRESS, 2015, 23 (22): : 28459 - 28470
  • [10] Mapping of a particular element using an absorption edge with an X-ray fluorescence imaging microscope
    Yamamoto, K
    Watanabe, N
    Takeuchi, A
    Takano, H
    Aota, T
    Fukuda, M
    Aoki, S
    JOURNAL OF SYNCHROTRON RADIATION, 2000, 7 (01) : 34 - 39