Technical and economic analysis of Brayton-cycle-based pumped thermal electricity storage systems with direct and indirect thermal energy storage

被引:28
作者
Zhang, Han [1 ,2 ]
Wang, Liang [1 ,2 ]
Lin, Xipeng [1 ]
Chen, Haisheng [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Inst Engn Thermophys, 11 Beisihuanxi Rd, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, 19A Yuquan Rd, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Nanjing Inst Future Energy Syst, Inst Engn Thermophys, 266 Chuangyan Rd, Nanjing 211135, Peoples R China
基金
中国国家自然科学基金;
关键词
Pumped thermal electricity storage; Brayton cycle; Indirect TES; Energy analysis; Economic analysis; PACKED-BED; SOLAR POWER; HEAT; PART; OPTIMIZATION; PERFORMANCE; TECHNOLOGY; FLOW;
D O I
10.1016/j.energy.2021.121966
中图分类号
O414.1 [热力学];
学科分类号
摘要
Pumped thermal electricity storage (PTES) systems have attracted increasing attention, owing to high energy density, low cost, flexible adjustable energy storage duration, and lack of geographical restrictions. At present, theoretical research for PTES is relatively deep. Further reduction of investment costs is of great value to its development and application. This paper proposes a 10-MW PTES system with indirect thermal energy storage (TES) (I-PTES). The I-PTES and a PTES system with direct TES (D-PTES) are analyzed and compared in terms of their technical and economic performances. The results show that the I-PTES is advantageous owing to its low installation cost when its electricity storage duration exceeds 6 h, despite bearing some loss in round-trip efficiency. For longer-duration electricity storage, the energy capital cost of I-PTES can be lower than 200 $/kWh, i.e., 40% lower than that of D-PTES, whereas the penalty for its round-trip efficiency can be less than 5% after optimization. For a 10-MW I-PTES system, the optimum round-trip efficiency and energy density can reach approximately 65% and 26 kWh/m(3), respectively. This research provides a more economical choice for the long-duration electricity storage, and a theoretical basis for the design and optimization of high-efficiency and low-capital-cost PTES systems (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:19
相关论文
共 61 条
[31]   A review of energy storage types, applications and recent developments [J].
Koohi-Fayegh, S. ;
Rosen, M. A. .
JOURNAL OF ENERGY STORAGE, 2020, 27
[32]  
Kurzke J, 2009, PROCEEDINGS OF THE ASME TURBO EXPO 2009, VOL 1, P145
[33]  
Laughlin RB, 2015, US Patent App, Patent No. [14/668:610, 14668610]
[34]  
Laughlin RB, 2016, US Patent App, Patent No. [12/932:775, 12932775]
[35]   Pumped thermal grid storage with heat exchange [J].
Laughlin, Robert B. .
JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2017, 9 (04)
[36]  
Li Y, 2021, PROGR PROSPECTS THER
[37]   Overview of current development in electrical energy storage technologies and the application potential in power system operation [J].
Luo, Xing ;
Wang, Jihong ;
Dooner, Mark ;
Clarke, Jonathan .
APPLIED ENERGY, 2015, 137 :511-536
[38]   HEAT-TRANSFER AND PRESSURE-DROP CORRELATIONS FOR THE RECTANGULAR OFFSET STRIP FIN COMPACT HEAT-EXCHANGER [J].
MANGLIK, RM ;
BERGLES, AE .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1995, 10 (02) :171-180
[39]  
Marguerre F, 1924, Mitteilungen der Vereinigung der Elektrizitatswerke, V354, P27
[40]   Parametric studies and optimisation of pumped thermal electricity storage [J].
McTigue, Joshua D. ;
White, Alexander J. ;
Markides, Christos N. .
APPLIED ENERGY, 2015, 137 :800-811