Quantitative Fourier transform ion cyclotron resonance mass spectrometry - the determination of creatinine by isotope dilution mass spectrometry

被引:4
作者
Bristow, T [1 ]
Stokes, P [1 ]
O'Connor, G [1 ]
机构
[1] Lab Govt Chemist, Teddington TW11 0LY, Middx, England
关键词
D O I
10.1002/rcm.1800
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Accurate quantitation has been demonstrated on many different types of mass spectrometer. However, quantitative applications of Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) have been limited. In this study, the quantitative potential of FTICRMS has been investigated using an exact matching isotope dilution method for the determination of creatinine in serum. Creatinine is an important clinical biomarker and its measurement is used as an assessment of renal function. The quantitation of creatinine was selected because a high-accuracy high-performance liquid chromatography/mass spectrometry (HPLC/MS) determination using a triple quadrupole mass spectrometer has already been successfully developed in-house. Therefore, a direct comparison of the quantitative capability of FTICRMS could be made against an established method. The accuracy of the quantitation of creatinine was found to be equivalent to that obtained using LC/MS. However, the expanded measurement uncertainty (k=2) was larger, at 6%, when using FTICRMS compared with 1% when using HPLC/MS with the triple quadrupole mass spectrometer. Copyright (C) 2005 John Wiley Sons, Ltd.
引用
收藏
页码:375 / 380
页数:6
相关论文
共 18 条
[1]  
Amster IJ, 1996, J MASS SPECTROM, V31, P1325
[2]   THE INFINITY CELL - A NEW TRAPPED-ION CELL WITH RADIOFREQUENCY COVERED TRAPPING ELECTRODES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CARAVATTI, P ;
ALLEMANN, M .
ORGANIC MASS SPECTROMETRY, 1991, 26 (05) :514-518
[3]  
Gordon EF, 1999, RAPID COMMUN MASS SP, V13, P164, DOI 10.1002/(SICI)1097-0231(19990215)13:3<164::AID-RCM474>3.0.CO
[4]  
2-L
[5]  
Gordon EF, 1999, J MASS SPECTROM, V34, P1055, DOI 10.1002/(SICI)1096-9888(199910)34:10<1055::AID-JMS864>3.0.CO
[6]  
2-E
[7]   Impact of ion cloud densities on the measurement of relative ion abundances in Fourier transform ion cyclotron resonance mass spectrometry: experimental observations of coulombically induced cyclotron radius perturbations and ion cloud dephasing rates [J].
Gordon, EF ;
Muddiman, DC .
JOURNAL OF MASS SPECTROMETRY, 2001, 36 (02) :195-203
[8]  
Henrion A., 1994, J ANAL CHEM+, V350, P657, DOI DOI 10.1007/BF00323658
[9]  
Lorenz SA, 1999, RAPID COMMUN MASS SP, V13, P2098, DOI 10.1002/(SICI)1097-0231(19991115)13:21<2098::AID-RCM759>3.3.CO
[10]  
2-F