ULA-OP 256: A 256-Channel Open Scanner for Development and Real-Time Implementation of New Ultrasound Methods

被引:129
作者
Boni, Enrico [1 ]
Bassi, Luca [1 ]
Dallai, Alessandro [1 ]
Guidi, Francesco [1 ]
Meacci, Valentino [1 ]
Ramalli, Alessandro [1 ]
Ricci, Stefano [1 ]
Tortoli, Piero [1 ]
机构
[1] Univ Florence, Dept Informat Engn, I-50139 Florence, Italy
基金
英国惠康基金;
关键词
High-frame-rate (HFR) imaging; open platform; programmable ultrasound system; research scanner; VELOCITY-MEASUREMENTS; DOPPLER ULTRASOUND; FREQUENCY-DOMAIN; IMAGING-SYSTEM; SKULL BONES; IN-VIVO; VECTOR; ARRAYS; ELASTOGRAPHY; SPECTRUM;
D O I
10.1109/TUFFC.2016.2566920
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Open scanners offer an increasing support to the ultrasound researchers who are involved in the experimental test of novel methods. Each system presents specific performance in terms of number of channels, flexibility, processing power, data storage capability, and overall dimensions. This paper reports the design criteria and hardware/software implementation details of a new 256-channel ultrasound advanced open platform. This system is organized in a modular architecture, including multiple front-end boards, interconnected by a high-speed (80 Gb/s) ring, capable of finely controlling all transmit (TX) and receive (RX) signals. High flexibility and processing power (equivalent to 2500 GFLOP) are guaranteed by the possibility of individually programming multiple digital signal processors and field programmable gate arrays. Eighty GB of on-board memory are available for the storage of prebeamforming, post-beamforming, and baseband data. The use of latest generation devices allowed to integrate all needed electronics in a small size (34 cm x 30 cm x 26 cm). The system implements a multiline beamformer that allows obtaining images of 96 lines by 2048 depths at a frame rate of 720 Hz (expandable to 3000 Hz). The multiline beamforming capability is also exploited to implement a real-time vector Doppler scheme in which a single TX and two independent RX apertures are simultaneously used to maintain the analysis over a full pulse repetition frequency range.
引用
收藏
页码:1488 / 1495
页数:8
相关论文
共 45 条
[1]   PROFOUND INCREASE IN LONGITUDINAL DISPLACEMENTS OF THE PORCINE CAROTID ARTERY WALL CAN TAKE PLACE INDEPENDENTLY OF WALL SHEAR STRESS: A CONTINUATION REPORT [J].
Ahlgren, Asa Ryden ;
Steen, Stig ;
Segstedt, Simon ;
Erlov, Tobias ;
Lindstrom, Kjell ;
Sjoberg, Trygve ;
Persson, Hans W. ;
Ricci, Stefano ;
Tortoli, Piero ;
Cinthio, Magnus .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (05) :1342-1353
[2]   A New Technique for the Estimation of Cardiac Motion in Echocardiography Based on Transverse Oscillations: A Preliminary Evaluation In Silico and a Feasibility Demonstration In Vivo [J].
Alessandrini, Martino ;
Basarab, Adrian ;
Boussel, Loic ;
Guo, Xinxin ;
Serusclat, Andre ;
Friboulet, Denis ;
Kouame, Denis ;
Bernard, Olivier ;
Liebgott, Herve .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (05) :1148-1162
[3]   Sparse 2-D Arrays for 3-D phased array imaging - Design methods [J].
Austeng, A ;
Holm, S .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) :1073-1086
[4]  
Boni E., 2015, P IEEE INT ULTR S IU, P1
[5]   A Reconfigurable and Programmable FPGA-Based System for Nonstandard Ultrasound Methods [J].
Boni, Enrico ;
Bassi, Luca ;
Dallai, Alessandro ;
Guidi, Francesco ;
Ramalli, Alessandro ;
Ricci, Stefano ;
Housden, James ;
Tortoli, Piero .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (07) :1378-1385
[6]   Multi-Channel Pre-Beamformed Data Acquisition System for Research on Advanced Ultrasound Imaging Methods [J].
Cheung, Chris C. P. ;
Yu, Alfred C. H. ;
Salimi, Nazila ;
Yiu, Billy Y. S. ;
Tsang, Ivan K. H. ;
Kerby, Benjamin ;
Azar, Reza Zahiri ;
Dickie, Kris .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (02) :243-253
[7]   Cumulative phase delay imaging for contrast-enhanced ultrasound tomography [J].
Demi, Libertario ;
van Sloun, Ruud J. G. ;
Wijkstra, Hessel ;
Mischi, Massimo .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (21) :L23-L33
[8]   Design of Optimal 2-D Nongrid Sparse Arrays for Medical Ultrasound [J].
Diarra, Bakary ;
Robini, Marc ;
Tortoli, Piero ;
Cachard, Christian ;
Liebgott, Herve .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (11) :3093-3102
[9]   Cross-beam vector Doppler ultrasound for angle-independent velocity measurements [J].
Dunmire, B ;
Beach, KW ;
Labs, KH ;
Plett, M ;
Strandness, DE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (08) :1213-1235
[10]   Three-dimensional ultrasound imaging [J].
Fenster, A ;
Downey, DB ;
Cardinal, HN .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05) :R67-R99