Heart-rate dependent improvement in image quality and diagnostic accuracy of coronary computed tomographic angiography by novel intracycle motion correction algorithm

被引:28
作者
Cho, Iksung [1 ,2 ,3 ,4 ]
Elmore, Kimberly [1 ,2 ]
Hartaigh, Briain O. [1 ,2 ]
Schulman-Marcus, Josh [1 ,2 ]
Granser, Heidi [5 ,6 ]
Valenti, Valentina [1 ,2 ]
Xiong, Guanglei [1 ,2 ]
Carrascosa, Patricia M. [7 ,8 ]
Min, James K. [1 ,2 ]
机构
[1] NewYork Presbyterian Hosp, Dept Radiol, New York, NY USA
[2] Weill Cornell Med Coll, New York, NY USA
[3] Yonsei Univ, Coll Med, Yonsei Univ Hlth Syst, Div Cardiol,Severance Cardiovasc Hosp, Seoul, South Korea
[4] Yonsei Univ, Coll Med, Yonsei Univ Hlth Syst, Severance Biomed Sci Inst, Seoul, South Korea
[5] Cedars Sinai Med Ctr, Cedars Sinai Heart Inst, Dept Imaging, Los Angeles, CA 90048 USA
[6] Cedars Sinai Med Ctr, Cedars Sinai Heart Inst, Dept Med, Los Angeles, CA 90048 USA
[7] Diagnost Maipu, CT Dept, Buenos Aires, DF, Argentina
[8] Diagnost Maipu, Dept Nucl Med, Buenos Aires, DF, Argentina
基金
美国国家卫生研究院;
关键词
Coronary computed tomographic angiography; Motion artifact; Motion correction algorithm; Coronary artery disease; CT ANGIOGRAPHY; ARTERY-DISEASE; PERFORMANCE; EXPERIENCE;
D O I
10.1016/j.clinimag.2014.11.020
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: To determine the effect of a novel intracycle motion correction algorithm (MCA) on diagnostic accuracy of coronary computed tomographic angiography. Methods: Coronary artery phantom models were scanned at static and heart rate (HR) simulation of 60-100 beat/min and reconstructed with a conventional algorithm and MCA. Results: Among 144 coronary segments, improvements in image interpretability, quality, and diagnostic accuracy by MCA were observed for HRs of 80 and 100 (P<.05 for all), but not for HR of 60. Conclusion: Novel intracycle MCA demonstrates improved HR-dependent image interpretability, and quality and accuracy, particularly at higher HRs. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:421 / 426
页数:6
相关论文
共 17 条
[1]  
Abbara Suhny, 2009, J Cardiovasc Comput Tomogr, V3, P190, DOI 10.1016/j.jcct.2009.03.004
[2]   64-multislice detector computed tomography coronary angiography as potential alternative to conventional coronary angiography: a systematic review and meta-analysis [J].
Abdulla, Jawdat ;
Abildstrom, Steen Z. ;
Gotzsche, Ole ;
Christensen, Erik ;
Kober, Lars ;
Torp-Pedersen, Christian .
EUROPEAN HEART JOURNAL, 2007, 28 (24) :3042-3050
[3]   Diagnostic Performance of 64-Multidetector Row Coronary Computed Tomographic Angiography for Evaluation of Coronary Artery Stenosis in Individuals Without Known Coronary Artery Disease [J].
Budoff, Matthew J. ;
Dowe, David ;
Jollis, James G. ;
Gitter, Michael ;
Sutherland, John ;
Halamert, Edward ;
Scherer, Markus ;
Bellinger, Raye ;
Martin, Arthur ;
Benton, Robert ;
Delago, Augustin ;
Min, James K. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (21) :1724-1732
[4]   LUMEN DIAMETER OF NORMAL HUMAN CORONARY-ARTERIES - INFLUENCE OF AGE, SEX, ANATOMIC VARIATION, AND LEFT-VENTRICULAR HYPERTROPHY OR DILATION [J].
DODGE, JT ;
BROWN, BG ;
BOLSON, EL ;
DODGE, HT .
CIRCULATION, 1992, 86 (01) :232-246
[5]  
Fleiss J. L., 1981, STAT METHODS RATES P
[6]   Impact of a New Motion-Correction Algorithm on Image Quality of Low-Dose Coronary CT Angiography in Patients with Insufficient Heart Rate Control [J].
Fuchs, Tobias A. ;
Stehli, Julia ;
Dougoud, Svetlana ;
Fiechter, Michael ;
Sah, Bert-Ram ;
Buechel, Ronny R. ;
Bull, Sacha ;
Gaemperli, Oliver ;
Kaufmann, Philipp A. .
ACADEMIC RADIOLOGY, 2014, 21 (03) :312-317
[7]   Technical challenges of coronary CT angiography: Today and tomorrow [J].
Hassan, Ali ;
Nazir, Sarfraz Ahmed ;
Alkadhi, Hatem .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (02) :161-171
[8]   Multi-detector row CT coronary angiography: Influence of reconstruction technique and heart rate on image quality [J].
Herzog, C ;
Arning-Erb, M ;
Zangos, S ;
Eichler, K ;
Hammerstingl, R ;
Dogan, S ;
Ackermann, H ;
Vogl, TJ .
RADIOLOGY, 2006, 238 (01) :75-86
[9]   Effect of a novel vendor-specific motion-correction algorithm on image quality and diagnostic accuracy in persons undergoing coronary CT angiography without rate-control medications [J].
Leipsic, Jonathon ;
Labounty, Troy M. ;
Hague, Cameron J. ;
Mancini, G. B. John ;
O'Brien, Julie M. ;
Wood, David A. ;
Taylor, Carolyn M. ;
Cury, Ricardo C. ;
Earls, James P. ;
Heilbron, Brett G. ;
Ajlan, Amr M. ;
Feuchtner, Gudrun ;
Min, James K. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (03) :164-171
[10]  
Lesser John R, 2009, J Cardiovasc Comput Tomogr, V3, P4, DOI 10.1016/j.jcct.2008.11.006