Alterations in human ECG due to the MagnetoHydroDynamic effect: A method for accurate R peak detection in the presence of high MHD artifacts

被引:35
作者
Abi-Abdallah, Dima [1 ]
Robin, Vincent [2 ]
Drochon, Agnes [1 ]
Fokapu, Odette [1 ,3 ]
机构
[1] Univ Technol Compiegne, Lab Biomech & Biomed Engn, F-60206 Compiegne, France
[2] Univ Technol Compiegne, Lab Appl Math, Compiegne, France
[3] Univ Picardie Jules Verne, Amiens, France
来源
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16 | 2007年
关键词
D O I
10.1109/IEMBS.2007.4352673
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Blood flow in high static magnetic fields induces elevated voltages that contaminate the ECG signal which is recorded simultaneously during MRI scans for synchronization purposes. This is known as the magnetohydrodynamic (MHD) effect, it increases the amplitude of the T wave, thus hindering correct R peak detection. In this paper, we inspect the MHD induced alterations of human ECG signals recorded in a 1.5 Testa steady magnetic field and establish a primary characterization of the induced changes using time and frequency domain analysis. We also reexamine our previously developed real time algorithm for MRI cardiac gating [1] and determine that, with a minor modification, this algorithm is capable of achieving perfect detection even in the presence of strong MHD artifacts.
引用
收藏
页码:1842 / +
页数:2
相关论文
共 13 条
[1]   Suppression of MR gradient artefacts on electrophysiological signals based on an adaptive real-time filter with LMS coefficient updates [J].
Abächerli, R ;
Pasquier, C ;
Odille, F ;
Kraemer, M ;
Schmid, JJ ;
Felblinger, J .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2005, 18 (01) :41-50
[2]  
ABDALLAH DA, 2006, BIOMED ENG ONLINE, V5
[3]   Cardiac and respiratory MRI gating using combined wavelet sub-band decomposition and adaptive filtering [J].
Abi-Abdallah, Dima ;
Drochon, Agnes ;
Robin, Vincent ;
Fokapu, Odette .
ANNALS OF BIOMEDICAL ENGINEERING, 2007, 35 (05) :733-743
[4]   Effect of static magnetic field exposure of up to 8 Tesla on sequential human vital sign measurements [J].
Chakeres, DW ;
Kangarlu, A ;
Boudoulas, H ;
Young, DC .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (03) :346-352
[5]  
DAMJI AA, 1988, MAGN RESON MED, V6, P89
[6]  
Felblinger J, 1999, MAGN RESON MED, V41, P715, DOI 10.1002/(SICI)1522-2594(199904)41:4<715::AID-MRM9>3.0.CO
[7]  
2-7
[8]  
Fischer SE, 1999, MAGN RESON MED, V42, P361, DOI 10.1002/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO
[9]  
2-9
[10]   ALTERATIONS IN THE RAT ELECTROCARDIOGRAM INDUCED BY STATIONARY MAGNETIC-FIELDS [J].
GAFFEY, CT ;
TENFORDE, TS .
BIOELECTROMAGNETICS, 1981, 2 (04) :357-370