Numerical analysis of crimping and inflation process of balloon-expandable coronary stent using implicit solution

被引:25
作者
Bukala, Jakub [1 ]
Kwiatkowski, Piotr [2 ]
Malachowski, Jerzy [1 ]
机构
[1] Mil Univ Technol, Dept Mech & Appl Comp Sci, Gen Sylwestra Kaliskiego 2, PL-00908 Warsaw, Poland
[2] Cent Clin Hosp Minist Interior, Clin Dept Intervent Cardiol, Woloska 137, PL-02507 Warsaw, Poland
关键词
analysis; coronary; finite element; implicit; numerical; stent; FINITE-ELEMENT-ANALYSIS; MECHANICAL-BEHAVIOR; CONTACT METHOD; SIMULATION; DESIGN; EXPLICIT; INTERVENTION; DEFORMATION;
D O I
10.1002/cnm.2890
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The paper presents an applied methodology for numerical finite element analysis of coronary stent crimping and the free inflation process with the use of a folded noncompliant angioplasty balloon. The use of an implicit scheme is considered as the most original part of the work, as an explicit finite element procedure is very often preferred. Hitherto, when the implicit solution was used for the finite element solution, the simulated issue was largely simplified. Therefore, the authors focused on the modelling methodology with minimum possible simplification, ie, a full load path (compression and inflation in single analysis), solid element discretization, and sophisticated contact models (bodies with highly different stiffness). The obtained results are partially compared with experimental data (radial force during the crimping procedure) and present satisfactory compliance. The authors believe that presented methodology allow for significant improvement of the obtained results, as well as potential extension of the research scope, compared to previous efforts performed using the explicit integration scheme. Moreover, the presented methodology is believed to be suitable for sensitivity and optimization studies.
引用
收藏
页数:11
相关论文
共 56 条
  • [11] Assessment of tissue prolapse after balloon-expandable stenting: Influence of stent cell geometry
    Capelli, Claudio
    Gervaso, Francesca
    Petrini, Lorenza
    Dubini, Gabriele
    Migliavacca, Francesco
    [J]. MEDICAL ENGINEERING & PHYSICS, 2009, 31 (04) : 441 - 447
  • [12] Conway C, 2012, Cardiovasc Eng Technol, V3, P374, DOI [10.1007/s13239-012-0104-8, DOI 10.1007/S13239-012-0104-8]
  • [13] EFFECTS OF BALLOON LENGTH AND COMPLIANCE ON VASCULAR STENT EXPANSION
    Cui, F. S.
    Lee, H. P.
    Lu, C.
    Chai, P.
    [J]. INTERNATIONAL JOURNAL OF APPLIED MECHANICS, 2010, 2 (03) : 681 - 697
  • [14] Realistic finite element-based stent design: The impact of balloon folding
    De Beule, Matthieu
    Mortier, Peter
    Carlier, Stphane G.
    Verhegghe, Benedict
    Van Impe, Rudy
    Verdonck, Pascal
    [J]. JOURNAL OF BIOMECHANICS, 2008, 41 (02) : 383 - 389
  • [15] A finite element strategy to investigate the free expansion behaviour of a biodegradable polymeric stent
    Debusschere, Nic
    Segers, Patrick
    Dubruel, Peter
    Verhegghe, Benedict
    De Beule, Matthieu
    [J]. JOURNAL OF BIOMECHANICS, 2015, 48 (10) : 2012 - 2018
  • [16] Mechanical behaviour modelling of balloon-expandable stents
    Dumoulin, C
    Cochelin, B
    [J]. JOURNAL OF BIOMECHANICS, 2000, 33 (11) : 1461 - 1470
  • [17] Finite element modeling of balloon angioplasty by considering overstretch of remnant non-diseased tissues in lesions
    Gasser, T. Christian
    Holzapfel, Gerhard A.
    [J]. COMPUTATIONAL MECHANICS, 2007, 40 (01) : 47 - 60
  • [18] Modelling of the provisional side-branch stenting approach for the treatment of atherosclerotic coronary bifurcations: effects of stent positioning
    Gastaldi, Dario
    Morlacchi, Stefano
    Nichetti, Roberto
    Capelli, Claudio
    Dubini, Gabriele
    Petrini, Lorenza
    Migliavacca, Francesco
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2010, 9 (05) : 551 - 561
  • [19] On the effects of different strategies in modelling balloon-expandable stenting by means of finite element method
    Gervaso, Francesca
    Capelli, Claudio
    Petrini, Lorenza
    Lattanzio, Simone
    Di Virgilio, Luca
    Migliavacca, Francesco
    [J]. JOURNAL OF BIOMECHANICS, 2008, 41 (06) : 1206 - 1212
  • [20] Simulation of stent deployment in a realistic human coronary artery
    Gijsen, Frank J. H.
    Migliavacca, Francesco
    Schievano, Silvia
    Socci, Laura
    Petrini, Lorenza
    Thury, Attila
    Wentzel, Jolanda J.
    van der Steen, Anton F. W.
    Serruys, Patrick W. S.
    Dubini, Gabriele
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2008, 7 (1)