Automatic removal of ocular artefacts using adaptive filtering and independent component analysis for electroencephalogram data

被引:50
作者
Guerrero-Mosquera, C. [1 ]
Navia-Vazquez, A. [1 ]
机构
[1] Univ Carlos III Madrid, Signal Theory & Commun Dept, Leganes 28911, Spain
关键词
EEG;
D O I
10.1049/iet-spr.2010.0135
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new method for eye movement artefacts removal based on independent component analysis (ICA) and recursive least squares (RLS) is presented. The proposed algorithm combines the effective ICA capacity of separating artefacts from brain waves, together with the online interference cancellation achieved by adaptive filtering. Eye blink, saccades, eyes opening and closing produce changes of potentials at frontal areas. For this reason, the method uses as a reference the electrodes closest to the eyes Fp1, Fp2, F7 and F8, which register vertical and horizontal eye movements in the electroencephalogram (EEG) caused by these activities as an alternative of using extra dedicated electrooculogram (EOG) electrodes, which could not always be available and could be subject to larger variability. Both reference signals and EEG components are first projected into ICA domain and then the interference is estimated using the RLS algorithm. The component related to EOG artefact is automatically eliminated using channel localisations. Results from experimental data demonstrate that this approach is suitable for eliminating artefacts caused by eye movements, and the principles of this method can be extended to certain other artefacts as well, whenever a correlated reference signal is available.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 50 条
[21]   Automatic Artifact Removal from Electroencephalogram Data Based on A Priori Artifact Information [J].
Zhang, Chi ;
Tong, Li ;
Zeng, Ying ;
Jiang, Jingfang ;
Bu, Haibing ;
Yan, Bin ;
Li, Jianxin .
BIOMED RESEARCH INTERNATIONAL, 2015, 2015
[22]   Artifacts Removal of EEG Signals using Adaptive Principal Component Analysis [J].
Turnip, Arjon ;
Kusumandari, Dwi Esti .
PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON COMPUTATION FOR SCIENCE AND TECHNOLOGY, 2015, 5 :172-175
[23]   Independent component analysis-based method for electroencephalogram analysis during photic stimulation [J].
Ferreira, Danton Diego ;
Mendes, Thais Martins ;
de Seixas, Jose Manoel ;
Cerqueira, Augusto Santiago ;
Leite Miranda de Sa, Antonio Mauricio Ferreira .
JOURNAL OF NEUROSCIENCE METHODS, 2014, 235 :252-261
[24]   Automatic Artifacts Removal of EEG Signals using Robust Principal Component Analysis [J].
Turnip, Arjon .
2014 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY, INFORMATICS, MANAGEMENT, ENGINEERING, AND ENVIRONMENT (TIME-E 2014), 2014, :331-334
[25]   Improved EOG Artifact Removal Using Wavelet Enhanced Independent Component Analysis [J].
Issa, Mohamed F. ;
Juhasz, Zoltan .
BRAIN SCIENCES, 2019, 9 (12)
[26]   A system for automatic artifact removal in ictal scalp EEG based on independent component analysis and Bayesian classification [J].
LeVan, P ;
Urrestarazu, E ;
Gotman, J .
CLINICAL NEUROPHYSIOLOGY, 2006, 117 (04) :912-927
[27]   Electrooculography Detection from Recorded Electroencephalogram Signals by Extended Independent Component Analysis [J].
Turnip, Arjon ;
Soetraprawata, Demi .
ADVANCED SCIENCE LETTERS, 2015, 21 (02) :173-176
[28]   Framework of Applying Independent Component Analysis After Compressed Sensing for Electroencephalogram Signals [J].
Kanemoto, Daisuke ;
Katsumata, Shun ;
Aihara, Masao ;
Ohki, Makoto .
2018 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): ADVANCED SYSTEMS FOR ENHANCING HUMAN HEALTH, 2018, :145-148
[29]   Muscle Artifact Removal from Human Sleep EEG by Using Independent Component Analysis [J].
Maite Crespo-Garcia ;
Mercedes Atienza ;
Jose L. Cantero .
Annals of Biomedical Engineering, 2008, 36 :467-475
[30]   Muscle artifact removal from human sleep EEG by using independent component analysis [J].
Crespo-Garcia, Maite ;
Atienza, Mercedes ;
Cantero, Jose L. .
ANNALS OF BIOMEDICAL ENGINEERING, 2008, 36 (03) :467-475