Hydroxyapatite coating on magnesium with MgF2 interlayer for enhanced corrosion resistance and biocompatibility

被引:78
作者
Jo, Ji-Hoon [1 ]
Kang, Bong-Gyu [1 ]
Shin, Kwang-Seon [1 ]
Kim, Hyoun-Ee [1 ]
Hahn, Byung-Dong [2 ]
Park, Dong-Soo [2 ]
Koh, Young-Hag [3 ]
机构
[1] Seoul Natl Univ, WCU Hybrid Mat Program, Dept Mat Sci & Engn, Seoul 151744, South Korea
[2] KIMS, Funct Ceram Grp, Funct Mat Div, Chang Won 641010, Gyeong Nam, South Korea
[3] Korea Univ, Dept Dent Lab Sci & Engn, Seoul 136706, South Korea
基金
新加坡国家研究基金会;
关键词
SIMULATED BODY-FLUID; IN-VITRO CORROSION; BONE IMPLANT APPLICATION; AEROSOL DEPOSITION; VIVO CORROSION; BIOMEDICAL APPLICATIONS; SURFACE MODIFICATION; DENTAL IMPLANTS; ALLOY AZ31; BIODEGRADATION;
D O I
10.1007/s10856-011-4431-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hydroxyapatite (HA) was coated onto pure magnesium (Mg) with an MgF2 interlayer in order to reduce the surface corrosion rate and enhance the biocompatibility. Both MgF2 and HA were successfully coated in sequence with good adhesion properties using the fluoride conversion coating and aerosol deposition techniques, respectively. In a simulated body fluid (SBF), the double layer coating remarkably enhanced the corrosion resistance of the coated Mg specimen. The in vitro cellular responses of the MC3T3-E1 pre-osteoblasts were examined using a cell proliferation assay and an alkaline phosphatase (ALP) assay, and these results demonstrated that the double coating layer also enhanced cell proliferation and differentiation levels. In the in vivo study, the HA/MgF2 coated Mg corroded less than the bare Mg and had a higher bone-to-implant contact (BIC) ratio in the cortical bone area of the rabbit femora 4 weeks after implantation. These in vitro and in vivo results suggested that the HA coated Mg with the MgF2 interlayer could be used as a potential candidate for biodegradable implant materials.
引用
收藏
页码:2437 / 2447
页数:11
相关论文
共 46 条
[1]   Aerosol deposition of ceramic thick films at room temperature: Densification mechanism of ceramic layers [J].
Akedo, Jun .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2006, 89 (06) :1834-1839
[2]   The response of bone to nanocrystalline hydroxyapatite-coated Ti13Nb11Zr alloy in an animal model [J].
Bigi, Adriana ;
Fini, Milena ;
Bracci, Barbara ;
Boanini, Elisa ;
Torricelli, Paola ;
GiavareSi, Gianluca ;
Aldini, Nicolo N. ;
Facchini, Alessandro ;
Sbaiz, Fausto ;
Giardino, Roberto .
BIOMATERIALS, 2008, 29 (11) :1730-1736
[3]   Characterization and corrosion studies of fluoride conversion coating on degradable Mg implants [J].
Chiu, K. Y. ;
Wong, M. H. ;
Cheng, F. T. ;
Man, H. C. .
SURFACE & COATINGS TECHNOLOGY, 2007, 202 (03) :590-598
[4]   A brief review of test methodologies for surface-engineered biomedical implant alloys [J].
Dearnley, PA .
SURFACE & COATINGS TECHNOLOGY, 2005, 198 (1-3) :483-490
[5]   Biological Performance of Chemical Hydroxyapatite Coating Associated With Implant Surface Modification by Laser Beam: Biomechanical Study in Rabbit Tibias [J].
Faeda, Rafael S. ;
Tavares, Hewerson S. ;
Sartori, Rafael ;
Guastaldi, Antonio C. ;
Marcantonio, Elcio, Jr. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (08) :1706-1715
[6]   The preparation, cytocompatibility, and in vitro biodegradation study of pure β-TCP on magnesium [J].
Geng, F. ;
Tan, L. L. ;
Jin, X. X. ;
Yang, J. Y. ;
Yang, K. .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2009, 20 (05) :1149-1157
[7]  
Gineste L, 1999, J BIOMED MATER RES, V48, P224, DOI 10.1002/(SICI)1097-4636(1999)48:3<224::AID-JBM5>3.0.CO
[8]  
2-A
[9]   Influence of surface modification on the in vitro corrosion rate of magnesium alloy AZ31 [J].
Gray-Munro, Joy E. ;
Seguin, Christine ;
Strong, Michael .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2009, 91A (01) :221-230
[10]   In vitro corrosion and biocompatibility of binary magnesium alloys [J].
Gu, Xuenan ;
Zheng, Yufeng ;
Cheng, Yan ;
Zhong, Shengping ;
Xi, Tingfei .
BIOMATERIALS, 2009, 30 (04) :484-498