Ex vivo testing of intact eye globes under inflation conditions to determine regional variation of mechanical stiffness

被引:49
作者
Whitford, Charles [1 ]
Joda, Akram [1 ,2 ]
Jones, Steve [1 ]
Bao, Fangjun [3 ]
Rama, Paolo [4 ]
Elsheikh, Ahmed [1 ,5 ,6 ]
机构
[1] Univ Liverpool, Sch Engn, Liverpool L69 3GH, Merseyside, England
[2] King Faisal Univ, Dept Mech Engn, Al Hufuf, Saudi Arabia
[3] WenZhou Med Univ, Hosp Eye, Wenzhou, Peoples R China
[4] San Raffaelle Hosp, Dept Ophthalmol, Milan, Italy
[5] Moorfields Eye Hosp NHS Fdn Trust, Natl Inst Hlth Res NIHR Biomed Res Ctr, London, England
[6] UCL Inst Ophthalmol, London, England
基金
英国工程与自然科学研究理事会;
关键词
Ocular biomechanics; Experimental testing; Digital image correlation; CORNEAL BIOMECHANICAL BEHAVIOR; STRAIN-RATE SENSITIVITY; PERIPAPILLARY SCLERA; CROSS-LINKING; ORGANIZATION; PORCINE; BOVINE; TISSUE; POSTERIOR; COMPRESSION;
D O I
10.1186/s40662-016-0052-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The eye globe exhibits significant regional variation of mechanical behaviour. The aim of this present study is to develop a new experimental technique for testing intact eye globes in a form that is representative of in vivo conditions, and therefore suitable for determining the material properties of the complete outer ocular tunic. Methods: A test rig has been developed to provide closed-loop control of either applied intra-ocular pressure or resulting apical displacement; measurement of displacements across the external surface of the eye globe using high-resolution digital cameras and digital image correlation software; prevention of rigid-body motion and protection of the ocular surface from environmental drying. The method has been demonstrated on one human and one porcine eye globe, which were cyclically loaded. Finite element models based on specimen specific tomography, free from rotational symmetry, were used along with experimental pressure-displacement data in an inverse analysis process to derive the mechanical properties of tissue in different regions of the eye's outer tunic. Results: The test method enabled monitoring of mechanical response to intraocular pressure variation across the surface of the eye globe. For the two eyes tested, the method showed a gradual change in the sclera's stiffness from a maximum at the limbus to a minimum at the posterior pole, while in the cornea the stiffness was highest at the centre and lowest in the peripheral zone. Further, for both the sclera and cornea, the load-displacement behaviour did not vary significantly between loading cycles. Conclusions: The first methodology capable of mechanically testing intact eye globes, with applied loads and boundary conditions that closely represent in vivo conditions is introduced. The method enables determination of the regional variation in mechanical behaviour across the ocular surface.
引用
收藏
页数:12
相关论文
共 55 条
[1]   3D Collagen Orientation Study of the Human Cornea Using X-ray Diffraction and Femtosecond Laser Technology [J].
Abahussin, Mohammad ;
Hayes, Sally ;
Cartwright, Nathaniel E. Knox ;
Kamma-Lorger, Christina S. ;
Khan, Yasir ;
Marshall, John ;
Meek, Keith M. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (11) :5159-5164
[2]   Transverse depth-dependent changes in corneal collagen lamellar orientation and distribution [J].
Abass, Ahmed ;
Hayes, Sally ;
White, Nick ;
Sorensen, Thomas ;
Meek, Keith M. .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2015, 12 (104)
[3]   X-ray scattering used to map the preferred collagen orientation in the human cornea and limbus [J].
Aghamohammadzadeh, H ;
Newton, RH ;
Meek, KM .
STRUCTURE, 2004, 12 (02) :249-256
[4]   Investigating endothelial invasion and sprouting behavior in three-dimensional collagen matrices [J].
Bayless, Kayla J. ;
Kwak, Hyeong-Il ;
Su, Shih-Chi .
NATURE PROTOCOLS, 2009, 4 (12) :1888-1898
[5]  
Bennett G, 2007, CLIN VISUAL OPTICS
[6]   Mapping collagen organization in the human cornea: Left and right eyes are structurally distinct [J].
Boote, C ;
Hayes, S ;
Abahussin, M ;
Meek, KM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (03) :901-908
[7]   PROTEOGLYCANS AND COLLAGEN FIBER ORGANIZATION IN HUMAN CORNEOSCLERAL TISSUE [J].
BORCHERDING, MS ;
BLACIK, LJ ;
SITTIG, RA ;
BIZZELL, JW ;
BREEN, M ;
WEINSTEIN, HG .
EXPERIMENTAL EYE RESEARCH, 1975, 21 (01) :59-70
[8]   Stress-controlled viscoelastic tensile response of bovine cornea [J].
Boyce, B. L. ;
Jones, R. E. ;
Nguyen, T. D. ;
Grazier, J. M. .
JOURNAL OF BIOMECHANICS, 2007, 40 (11) :2367-2376
[9]   Full-field deformation of bovine cornea under constrained inflation conditions [J].
Boyce, Brad L. ;
Grazier, J. Mark ;
Jones, Reese E. ;
Nguyen, Thao D. .
BIOMATERIALS, 2008, 29 (28) :3896-3904
[10]   Constitutive laws for biomechanical modeling of refractive surgery [J].
Bryant, MR ;
McDonnell, PJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (04) :473-481