Modeling of Inter-Turn and Inter-Phase Short-Circuit of Flux-Switching Permanent Magnet Motors

被引:0
作者
Li, Guang-Jin [1 ]
Zhu, Zi-Qiang [1 ]
Gabsi, Mohamed [2 ]
Griffo, Antonio [1 ]
Ojeda, Javier [2 ]
机构
[1] Univ Sheffield, Dept Elect & Elect Engn, Sheffield, S Yorkshire, England
[2] Ecole Normale Super Paris Saclay, SATIE, Cachan, France
来源
2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE) | 2018年
关键词
fault diagnosis; flux-switching; inter-turn short circuit; permanent magnet; synchronous motor; SYNCHRONOUS MOTOR; MACHINES; STATOR;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents an approach for detailed modelling of inter-turn and inter-phase short-circuit in a double layer, 12-slot and 10-pole Flux-Switching Permanent Magnet motor. This approach is based on MATLAB/Simulink and finite element analysis, and shows a fast and accurate estimation of the electromagnetic behavior for such machine under short-circuit conditions. Due to physical contact between different phase windings in the same stator slot, the inter-turn and inter-phase short-circuit in a double layer FSPM machine becomes a real possibility. However, this is rarely studied in the literature. Thus, this work contributes for the fault analysis of inter-turn and inter phase short-circuit problems. Experimental tests have been carried out to validate the simulations.
引用
收藏
页码:6476 / 6483
页数:8
相关论文
共 50 条
  • [21] Analysis of Stator Winding Inter-turn Short-circuit Fault in Interior and Surface Mounted Permanent Magnet Traction Machines
    Lai, Chunyan
    Balamurali, Aiswarya
    Bousaba, Vicki
    Iyer, K. Lakshmi Varaha
    Kar, Narayan C.
    2014 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO (ITEC), 2014,
  • [22] Scaling Effect on Inter-Turn Short-Circuit of PM Machines for Wind Power Application
    Mei, Z. T.
    Li, G. J.
    Zhu, Z. Q.
    Clark, R.
    Thomas, A.
    Azar, Z.
    2021 IEEE INTERNATIONAL ELECTRIC MACHINES & DRIVES CONFERENCE (IEMDC), 2021,
  • [23] Detection of inter-turn short-circuit in induction motors using Park-Hilbert method
    Sahraoui M.
    Ghoggal A.
    Guedidi S.
    Zouzou S.E.
    International Journal of System Assurance Engineering and Management, 2014, 5 (3) : 337 - 351
  • [24] Fault diagnosis of inter-turn short circuit of permanent magnet synchronous motor based on deep learning
    Li Y.-J.
    Zhang Z.-L.
    Li M.-H.
    Wei H.-F.
    Zhang Y.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2020, 24 (09): : 173 - 180
  • [25] Inter-Turn Short Circuit Fault Diagnosis of PMSM
    Chen, Xinglong
    Qin, Peng
    Chen, Yongyi
    Zhao, Jianjian
    Li, Wenhao
    Mao, Yao
    Zhao, Tao
    ELECTRONICS, 2022, 11 (10)
  • [26] Fault coil location of inter-turn short-circuit for direct-drive permanent magnet synchronous motor using knowledge graph
    Lv, Ke
    Gao, Caixia
    Si, Jikai
    Feng, Haichao
    Cao, Wenping
    IET ELECTRIC POWER APPLICATIONS, 2020, 14 (09) : 1712 - 1721
  • [27] Novel Approach to Fault-Tolerant Control of Inter-Turn Short Circuits in Permanent Magnet Synchronous Motors for UAV Propellers
    Suti, Aleksander
    Di Rito, Gianpietro
    Galatolo, Roberto
    AEROSPACE, 2022, 9 (08)
  • [28] BACKSTEPPING CONTROL OF A SWITCHED RELUCTANCE MOTOR WITH INTER-TURN SHORT-CIRCUIT
    Abdelouhab, Mostafa
    Attar, Abdelilah
    Aboutni, Rachid
    Bouchnaif, Jamal
    ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2022, 20 (03) : 250 - 259
  • [29] On the risk of failure to prevent induction motors permanent damage, due to the short available time-to-diagnosis of inter-turn short-circuit faults
    Bento, Fernando
    Adouni, Amel
    Muxiri, Ananias C. P.
    Fonseca, Davide S. B.
    Marques Cardoso, Antonio J.
    IET ELECTRIC POWER APPLICATIONS, 2021, 15 (01) : 51 - 62
  • [30] Mixed resistive unbalance and winding inter-turn faults model of permanent magnet synchronous motors
    Julio-César Urresty
    Jordi-Roger Riba
    Luís Romeral
    Juan Antonio Ortega
    Electrical Engineering, 2015, 97 : 75 - 85