Comparative study of 2-hydroxy propyl beta cyclodextrin and calixarene as ionophores in potentiometric ion-selective electrodes for neostigmine bromide

被引:45
作者
El-Kosasy, Amira M. [2 ]
Nebsen, Marianne [1 ]
Abd El-Rahman, Mohamed K. [1 ]
Salem, Maissa Y. [1 ]
El-Bardicy, Mohamed G. [1 ]
机构
[1] Cairo Univ, Fac Pharm, Dept Analyt Chem, Cairo 11562, Egypt
[2] Ain Shams Univ, Fac Pharm, Dept Pharmaceut Analyt Chem, Cairo 11566, Egypt
关键词
Neostigmine bromide; 2-Hydroxy propyl beta-cyclodextrin; Calixarene; Potentiometry; Stability-indicating method; Plasma; Cerebrospinal fluid; CAPILLARY-ZONE-ELECTROPHORESIS; MEMBRANE ELECTRODES; COPPER(II) ION; COUNTERFLOW; DERIVATIVES;
D O I
10.1016/j.talanta.2011.04.071
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three novel neostigmine bromide (NEO) selective electrodes were investigated with 2-nitrophenyl octyl ether as a plasticiser in a polymeric matrix of polyvinyl chloride (PVC). Sensor 1 was fabricated using tetrakis(4-chlorophenyl)borate (TpClPB) as an anionic exchanger without incorporation of an ionophore. Sensor 2 used 2-hydroxy propyl beta-cyclodextrin as an ionophore while sensor 3 was constructed using 4-sulfocalix-8-arene as an ionophore. Linear responses of NEO within the concentration ranges of 10(-5) to 10(-2), 10(-6) to 10(-2) and 10(-7) to 10(-2) Mol L(-1) were obtained using sensors 1, 2 and 3, respectively. Nernstian slopes of 51.6 +/- 0.8, 52.9 +/- 0.6 and 58.6 +/- 0.4 mV/decade over the pH range of 4-9 were observed. The selectivity coefficients of the developed sensors indicated excellent selectivity for NEO. The utility of 2-hydroxy propyl beta-cyclodextrin and 4-sulfocalix[8]arene as ionophores had a significant influence on increasing the membrane sensitivity and selectivity of sensors 2 and 3 compared to sensor 1. The proposed sensors displayed useful analytical characteristics for the determination of NEO in bulk powder, different pharmaceutical formulations, and biological fluids (plasma and cerebrospinal fluid (CSF)) and in the presence of its degradation product (3-hydroxyphenyltrimethyl ammonium bromide) and thus could be used for stability-indicating methods. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:913 / 918
页数:6
相关论文
共 37 条
[1]  
[Anonymous], 2004, US PHARM
[2]   Electrochemical sensors [J].
Bakker, Eric ;
Qin, Yu .
ANALYTICAL CHEMISTRY, 2006, 78 (12) :3965-3983
[3]  
BIRGIT K, 2002, ANAL CHEM, V74, P3005
[4]   Double-armed calix[4]arene amide derivatives as ionophores for lead ion-selective electrodes [J].
Chen, LX ;
Zhang, J ;
Zhao, WF ;
He, XW ;
Liu, Y .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 589 (01) :106-111
[5]   Counterflow isotachophoresis capillary zone electrophoresis on directly coupled columns of different diameters [J].
Chen, SJ ;
Lee, ML .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3777-3780
[6]   POTENTIOMETRIC TITRATION OF PHARMACEUTICAL COMPOUNDS IN FORMULATIONS WITH SODIUM TETRAPHENYLBORATE [J].
DIAMANDIS, EP ;
CHRISTOPOULOS, TK .
ANALYTICA CHIMICA ACTA, 1983, 152 (SEP) :281-284
[7]  
El-Kosasy AM, 2003, J AOAC INT, V86, P15
[8]  
El-Kosasy AM, 2009, J AOAC INT, V92, P1631
[9]  
Fan J., 1988, ZHONGGUO YAOKE DAXUE, V19, P58
[10]  
Flink S, 2000, ADV MATER, V12, P1315