A rapid and sensitive chemiluminescence immunoassay based on magnetic particles for squamous cell carcinoma antigen in human serum

被引:33
作者
Zhang, Huisheng [1 ]
Qi, Suwen [1 ]
机构
[1] Shenzhen Univ, Sch Med, Dept Biomed Engn, Shenzhen 518020, Guangdong, Peoples R China
关键词
Chemiluminescence immunoassay; Squamous cell carcinoma antigen; Magnetic particles; ALPHA-FETOPROTEIN AFP; ENZYME-IMMUNOASSAY; SCC ANTIGEN; CARCINOEMBRYONIC ANTIGEN; TUMOR-ANTIGEN; MARKER; HEAD; RADIOIMMUNOASSAY; RECURRENCE; DIAGNOSIS;
D O I
10.1016/j.cca.2011.05.005
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Because squamous cell carcinoma antigen (SCCa) quantification has demonstrated strong clinical potential, we describes rapid and highly sensitive magnetic particle-based chemiluminescence immunoassay (CLIA) technique for assaying SCCa in serum. Methods: Fluorescein isothiocyanate (FITC) and N-(aminobutyl)-N-(ethylisoluminol) (ABEI) were used to label 2 different monoclonal antibodies of anti-SCCa. Both of the labeled antibodies combined with SCCa to form a sandwiched immunoreaction that was monitored by chemiluminescence (CL) detection. The magnetic particles (MPs) that were coated with anti-FITC antibody served as both the solid phase and the separator. The relevant variables involved in the CLIA signals were optimized and the parameters of the proposed method were evaluated. Results: The method was linear to 20 ng/ml SCCa with a detection limit of 0.02 ng/ml. The intra-assay imprecision results [mean (CV)] were 1.12 ng/ml (3.81%), 2.58 ng/ml (2.53%) and [6.56 ng/ml (2.24%)]: the inter-assay imprecision results were 11.18 ng/ml (5.26%)], [2.49 ng/ml (4.75%)] and 16.61 ng/ml (4.29%)]. The average recoveries were between 97% and 104%. The relationship between the concentration of diluted SCCa and the dilution ratios gave a linear correlation coefficient of 0.9995. A correlation analysis against an established automated assay generated a slope of 0.9929 and an intercept of 0.0039 ng/ml (r = 0.9964). Conclusions: The proposed method demonstrates an acceptable performance for quantifying serum SCCa and is suitable for the fabrication of a commercial kit with application in the automated CL analyzer. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1572 / 1577
页数:6
相关论文
共 50 条
  • [21] Detection of urinary survivin using a magnetic particles-based chemiluminescence immunoassay for the preliminary diagnosis of bladder cancer and renal cell carcinoma combined with LAPTM4B
    Yang, Yang
    Xu, Jianjun
    Zhang, Qingyun
    [J]. ONCOLOGY LETTERS, 2018, 15 (05) : 7923 - 7933
  • [22] Postoperative serum squamous cell carcinoma antigen and carcinoembryonic antigen predict overall survival in surgical patients with esophageal squamous cell carcinoma
    Huang, Yi
    Liu, Fangfang
    Xu, Ruiping
    Zhou, Fuyou
    Yang, Wenlei
    He, Yu
    Liu, Zhen
    Hou, Bolin
    Liang, Linlin
    Zhang, Lixin
    Liu, Mengfei
    Pan, Yaqi
    Liu, Ying
    He, Zhonghu
    Ke, Yang
    [J]. FRONTIERS IN ONCOLOGY, 2023, 13
  • [23] Micro-plate magnetic chemiluminescence enzyme immunoassay for rapid, sensitive determination of human chorionic gonadotropin (HCG)
    Zhao, LX
    Lin, JM
    Qu, F
    [J]. ACTA CHIMICA SINICA, 2004, 62 (01) : 71 - 77
  • [24] Diagnostic accuracy of serum squamous cell carcinoma antigen and squamous cell carcinoma antigen-immunoglobulin M for hepatocellular carcinoma: A meta-analysis
    Zhang, Jian
    Shao, Chuxiao
    Zhou, Qingyun
    Zhu, Yimin
    Zhu, Jinde
    Tu, Chaoyong
    [J]. MOLECULAR AND CLINICAL ONCOLOGY, 2015, 3 (05) : 1165 - 1171
  • [25] Evaluation of α-fetoprotein (AFP) in human serum by chemiluminescence enzyme immunoassay with magnetic particles and coated tubes as solid phases
    Zhang, Qianyun
    Wang, Xu
    Li, Zhenjia
    Lin, Jin-Ming
    [J]. ANALYTICA CHIMICA ACTA, 2009, 631 (02) : 212 - 217
  • [26] Prognostic value of human papillomavirus and squamous cell carcinoma antigen in head and neck squamous cell carcinoma
    Deng, Zeyi
    Hasegawa, Masahiro
    Yamashita, Yukashi
    Matayoshi, Sen
    Kiyuna, Asanori
    Agena, Shinya
    Uehara, Takayuki
    Maeda, Hiroyuki
    Suzuki, Mikio
    [J]. CANCER SCIENCE, 2012, 103 (12) : 2127 - 2134
  • [27] A dual-label time-resolved fluorescence immunoassay for the simultaneous determination of carcinoembryonic antigen and squamous cell carcinoma antigen
    Mao, Qian
    Liu, Xiaohong
    Chen, CuiCui
    Ye, Jingwen
    Liang, Huankun
    Li, Binxian
    Sun, Xinyi
    Sun, Lin
    Sun, Yuman
    Mu, Xiaomei
    Li, Laiqing
    [J]. BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2018, 65 (06) : 816 - 821
  • [28] Multifunctional reduced graphene oxide trigged chemiluminescence resonance energy transfer: Novel signal amplification strategy for photoelectrochemical immunoassay of squamous cell carcinoma antigen
    Zhang, Yan
    Sun, Guoqiang
    Yang, Hongmei
    Yu, Jinghua
    Yan, Mei
    Song, Xianrang
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 79 : 55 - 62
  • [29] A rapid and sensitive method based on magnetic beads for the detection of hepatitis B virus surface antigen in human serum
    Ren, Zhi-Qi
    Liu, Tian-Cai
    Hou, Jing-Yuan
    Chen, Mei-Jun
    Chen, Zhen-Hua
    Lin, Guan-Feng
    Wu, Ying-Song
    [J]. LUMINESCENCE, 2014, 29 (06) : 591 - 597
  • [30] Diagnostic value of serum squamous cell carcinoma antigen and cytokeratin fragment antigen 21-1 for sinonasal inverted papilloma: an exploratory study
    Zhang, Zengxiao
    Xu, Bingqing
    Wang, Lin
    Yan, Xudong
    Li, Shunke
    Jiang, Yan
    Yu, Longgang
    [J]. RHINOLOGY, 2024, 62 (03) : 353 - 363