A real-time ultrasonic field mapping system using a Fabry Perot single pixel camera for 3D photoacoustic imaging

被引:8
作者
Huynh, Nam [1 ]
Zhang, Edward [1 ]
Betcke, Marta [2 ]
Arridge, Simon [2 ]
Beard, Paul [1 ]
Cox, Ben [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6BT, England
[2] UCL, Dept Comp Sci, London WC1E 6BT, England
来源
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2015 | 2015年 / 9323卷
关键词
Photoacoustic imaging; digital micromirror array; ultrasound field mapping; real time; compressed sensing; POLYMER-FILM; SENSOR; RECOVERY;
D O I
10.1117/12.2081869
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A system for dynamic mapping of broadband ultrasound fields has been designed, with high frame rate photoacoustic imaging in mind. A Fabry-Perot interferometric ultrasound sensor was interrogated using a coherent light single-pixel camera. Scrambled Hadamard measurement patterns were used to sample the acoustic field at the sensor, and either a fast Hadamard transform or a compressed sensing reconstruction algorithm were used to recover the acoustic pressure data. Frame rates of 80 Hz were achieved for 32x32 images even though no specialist hardware was used for the on-thefly reconstructions. The ability of the system to obtain photocacoustic images with data compressions as low as 10% was also demonstrated.
引用
收藏
页数:7
相关论文
共 20 条
[1]   Fast Image Recovery Using Variable Splitting and Constrained Optimization [J].
Afonso, Manya V. ;
Bioucas-Dias, Jose M. ;
Figueiredo, Mario A. T. .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2010, 19 (09) :2345-2356
[2]   Biomedical photoacoustic imaging [J].
Beard, Paul .
INTERFACE FOCUS, 2011, 1 (04) :602-631
[3]   Extrinsic optical-fiber ultrasound sensor using a thin polymer film as a low-finesse Fabry-Perot interferometer [J].
Beard, PC ;
Mills, TN .
APPLIED OPTICS, 1996, 35 (04) :663-675
[4]   Stable signal recovery from incomplete and inaccurate measurements [J].
Candes, Emmanuel J. ;
Romberg, Justin K. ;
Tao, Terence .
COMMUNICATIONS ON PURE AND APPLIED MATHEMATICS, 2006, 59 (08) :1207-1223
[5]   Bandwidth improvement of LiNbO3 ultrasonic transducers by half-concaved inversion layer approach [J].
Chen, J. ;
Dai, J. Y. ;
Zhang, C. ;
Zhang, Z. T. ;
Feng, G. P. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (11)
[6]   A Fast Acoustic Field Mapping Approach Based on Fabry-Perot Sensor with High-Speed Camera [J].
Cong, Bing ;
Kondo, Kengo ;
Yamakawa, Makoto ;
Shiina, Tsuyoshi ;
Nakajima, Takao ;
Asao, Yasufumi .
IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2014, 9 (05) :477-483
[7]   Fast and Efficient Compressive Sensing Using Structurally Random Matrices [J].
Do, Thong T. ;
Gan, Lu ;
Nguyen, Nam H. ;
Tran, Trac D. .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2012, 60 (01) :139-154
[8]   Glancing angle deposited nanostructured film Fabry-Perot etalons for optical detection of ultrasound [J].
Hajireza, Parsin ;
Krause, Kathleen ;
Brett, Michael ;
Zemp, Roger .
OPTICS EXPRESS, 2013, 21 (05) :6391-6400
[9]   High frequency optoacoustic arrays using etalon detection [J].
Hamilton, JD ;
Buma, T ;
Spisar, M ;
O'Donnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (01) :160-169
[10]  