A Multivariate Polynomial Regression to Reconstruct Ground Contact and Flight Times Based on a Sine Wave Model for Vertical Ground Reaction Force and Measured Effective Timings

被引:0
作者
Patoz, Aurelien [1 ,2 ]
Lussiana, Thibault [2 ,3 ,4 ]
Breine, Bastiaan [2 ,5 ]
Gindre, Cyrille [2 ]
Malatesta, Davide [1 ]
机构
[1] Univ Lausanne, Inst Sport Sci, Lausanne, Switzerland
[2] Swiss Sport Lab, Res & Dev Dept Volodalen, Aigle, Switzerland
[3] Res & Dev Dept Volodalen, Chaveria, France
[4] Univ Franche Comte, Prognost Markers & Regulatory Factors Cardiovascu, Res Unit, EA3920, Besancon, France
[5] Univ Ghent, Dept Movement & Sports Sci, Ghent, Belgium
关键词
running; biomechanics; sensors; inertial measurement unit; machine learning; FOOT STRIKE PATTERN; BIOMECHANICS; GAIT; RELIABILITY; STIFFNESS; MACROPUS; WORK;
D O I
10.3389/fbioe.2021.687951
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Effective contact ( t ce ) and flight ( t fe ) times, instead of ground contact ( tc ) and flight ( tf ) times, are usually collected outside the laboratory using inertial sensors. Unfortunately, t ce and t fe cannot be related to tc and tf because the exact shape of vertical ground reaction force is unknown. However, using a sine wave approximation for vertical force, t ce and tc as well as t fe and tf could be related. Indeed, under this approximation, a transcendental equation was obtained and solved numerically over a t ce x t fe grid. Then, a multivariate polynomial regression was applied to the numerical outcome. In order to reach a root-mean-square error of 0.5 ms, the final model was given by an eighth-order polynomial. As a direct application, this model was applied to experimentally measured t ce values. Then, reconstructed tc (using the model) was compared to corresponding experimental ground truth. A systematic bias of 35 ms was depicted, demonstrating that ground truth tc values were larger than reconstructed ones. Nonetheless, error in the reconstruction of tc from t ce was coming from the sine wave approximation, while the polynomial regression did not introduce further error. The presented model could be added to algorithms within sports watches to provide robust estimations of tc and tf in real time, which would allow coaches and practitioners to better evaluate running performance and to prevent running-related injuries.
引用
收藏
页数:9
相关论文
共 44 条
[1]   Stride adjustments during a running approach toward a force plate [J].
AbendrothSmith, J .
RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 1996, 67 (01) :97-101
[2]   Sacral acceleration can predict whole-body kinetics and stride kinematics across running speeds [J].
Alcantara, Ryan S. ;
Day, Evan M. ;
Hahn, Michael E. ;
Grabowski, Alena M. .
PEERJ, 2021, 9
[4]   ACCURACY OF PARTWEAR INERTIAL SENSOR AND OPTOJUMP OPTICAL MEASUREMENT SYSTEM FOR MEASURING GROUND CONTACT TIME DURING RUNNING [J].
Ammann, Rahel ;
Taube, Wolfgang ;
Wyss, Thomas .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2016, 30 (07) :2057-2063
[5]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[6]   Predicting cumulative load during running using field-based measures [J].
Backes, Anne ;
Skejo, Sebastian Deisting ;
Gette, Paul ;
Nielsen, Rasmus Ostergaard ;
Sorensen, Henrik ;
Morio, Cedric ;
Malisoux, Laurent .
SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2020, 30 (12) :2399-2407
[7]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[8]  
Brent R., 1973, Algorithms for Minimization without Derivatives
[9]  
Broyden C. G., 1970, Journal of the Institute of Mathematics and Its Applications, V6, P222
[10]   Trends Supporting the In-Field Use of Wearable Inertial Sensors for Sport Performance Evaluation: A Systematic Review [J].
Camomilla, Valentina ;
Bergamini, Elena ;
Fantozzi, Silvia ;
Vannozzi, Giuseppe .
SENSORS, 2018, 18 (03)