Fatigue durability of cracked steel beams retrofitted with high-strength materials
被引:19
|
作者:
Yu, Qian-Qian
论文数: 0引用数: 0
h-index: 0
机构:
Tongji Univ, Dept Struct Engn, Shanghai, Peoples R China
City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong, Hong Kong, Peoples R ChinaTongji Univ, Dept Struct Engn, Shanghai, Peoples R China
Yu, Qian-Qian
[1
,3
]
Wu, Yu-Fei
论文数: 0引用数: 0
h-index: 0
机构:
RMIT Univ, Sch Engn, Melbourne, Vic, Australia
City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong, Hong Kong, Peoples R ChinaTongji Univ, Dept Struct Engn, Shanghai, Peoples R China
Wu, Yu-Fei
[2
,3
]
机构:
[1] Tongji Univ, Dept Struct Engn, Shanghai, Peoples R China
[2] RMIT Univ, Sch Engn, Melbourne, Vic, Australia
[3] City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong, Hong Kong, Peoples R China
Steel structures under dynamic loading are prone to fatigue damage and a considerable number of metallic infrastructure in the world are structurally deficient. The fatigue behavior of defected steel beams mechanically retrofitted by different high-strength materials was experimentally studied in this work. The steel beam was I section with an artificial cut at the mid-span and tested under fatigue loading. The specimens were strengthened on the tension flange by carbon fiber reinforced polymer (CFRP) laminate, high strength steel (HSS) plate or SafStrip (SAF) plate. Three mechanical anchorage schemes were designed to test their efficiencies. The fatigue crack propagation was recorded to explore the crack growth rate. Strain gauges were installed on the strengthening material to monitor the strain development. The stress intensity factor (SIF) at the crack front was calculated based on analytical solution and numerical simulation; then, the results were compared with experimental findings. It was demonstrated that the strengthening significantly increased the fatigue life of the beams. The attached strengthening materials not only globally shared a portion of the far-field load on the cracked steel section but also provided a local constraining effect, both of which reduced the crack mouth opening displacement (CMOD) and SIF. The different CMODs resulted from the different retrofitting configurations indicated significant variation in the crack constraining effect caused by various retrofitting systems, which cannot be neglected in analytical modeling. (C) 2017 Elsevier Ltd. All rights reserved.
机构:
London South Bank Univ, Sch Build Environm & Architecture, Div Civil & Bldg Serv Engn, London, EnglandLondon South Bank Univ, Sch Build Environm & Architecture, Div Civil & Bldg Serv Engn, London, England
Shamass, Rabee
Guarracino, Federico
论文数: 0引用数: 0
h-index: 0
机构:
Univ Naples Federico II, Dept Struct Engn, Via Claudio 21, I-80125 Naples, ItalyLondon South Bank Univ, Sch Build Environm & Architecture, Div Civil & Bldg Serv Engn, London, England