Combined simulation of central HVAC systems with a whole-building hygrothermal model

被引:53
|
作者
Barbosa, Rogerio Marcos [1 ]
Mendes, Nathan [1 ]
机构
[1] Pontif Cathol Univ Parana PUCPR CCET, Thermal Syst Labs LST, BR-80215901 Curitiba, Parana, Brazil
关键词
moisture; HVAC systems; hygrothermal simulation;
D O I
10.1016/j.enbuild.2007.02.022
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to the lack of building simulation programs that can simulate in details the combined heat, vapor and liquid transfer in porous elements and the HVAC systems, a generic and flexible computational algorithm has been elaborated in order to integrate models for both HVAC systems and multizone building hygrothermal model. In the algorithm, models for the primary components (chiller, cooling tower, primary pumps and condensation pumps) and for the secondary components (cooling and dehumidifying coil, humidifier, fan and mixing box) have been presented. Those mathematical models have been integrated into a whole-building simulation model, allowing to perform whole-building hygrothermal simulation combined to HVAC systems and plant simulation. The building hygrothermal model is based on the simultaneous calculation of temperature and moisture content distributions within the porous envelope taking into account both vapor diffusion and capillary migration. First, results are presented for a multizone building to show the usability of the proposed algorithm. Then, the analysis of the influence of the adsorption and desorption phenomena on the calculation of thermal loads and energy consumption is presented, showing that the disregard of moisture may oversize the HVAC system in 13% and underestimate the cooling energy consumption in 4% for the case study defined in this paper. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:276 / 288
页数:13
相关论文
共 50 条
  • [1] An improved explicit scheme for whole-building hygrothermal simulation
    Gasparin, Suelen
    Berger, Julien
    Dutykh, Denys
    Mendes, Nathan
    BUILDING SIMULATION, 2018, 11 (03) : 465 - 481
  • [2] An improved explicit scheme for whole-building hygrothermal simulation
    Suelen Gasparin
    Julien Berger
    Denys Dutykh
    Nathan Mendes
    Building Simulation, 2018, 11 : 465 - 481
  • [3] Determination of indoor humidity profile using a whole-building hygrothermal model
    Tariku, Fitsum
    Kumaran, Kumar
    Fazio, Paul
    BUILDING SIMULATION, 2011, 4 (01) : 61 - 78
  • [4] Determination of indoor humidity profile using a whole-building hygrothermal model
    Fitsum Tariku
    Kumar Kumaran
    Paul Fazio
    Building Simulation, 2011, 4 : 61 - 78
  • [5] 2D whole-building hygrothermal simulation analysis based on a PGD reduced order model
    Berger, Julien
    Mazuroski, Walter
    Mendes, Nathan
    Guernouti, Sihem
    Woloszyn, Monika
    ENERGY AND BUILDINGS, 2016, 112 : 49 - 61
  • [6] Analysis of Whole-Building HVAC System Energy Efficiency
    Liao, Jiajun
    Claridge, David E.
    Wang, Linyan
    ASHRAE TRANSACTIONS, VOL 124, PT 1, 2018, 124 : 72 - 87
  • [7] Erratum to: Determination of indoor humidity profile using a whole-building hygrothermal model
    Fitsum Tariku
    Kumar Kumaran
    Paul Fazio
    Building Simulation, 2011, 4 : 277 - 277
  • [8] Whole-building commercial HVAC system simulation for use in energy consumption fault detection
    Lee, Seung Uk
    Painter, Frank L.
    Claridge, David E.
    ASHRAE TRANSACTIONS 2007 VOL 113, PT 2, 2007, 113 : 52 - 61
  • [9] Application of a Whole-Building Hygrothermal model in energy, durability, and indoor humidity retrofit design
    Tariku, Fitsum
    Kumaran, Kumar
    Fazio, Paul
    JOURNAL OF BUILDING PHYSICS, 2015, 39 (01) : 3 - 34
  • [10] Can crawl space temperature and moisture conditions be calculated with a whole-building hygrothermal simulation tool?
    Vanhoutteghem, Lies
    Morelli, Martin
    Sorensen, Lars Schiott
    11TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB2017), 2017, 132 : 688 - 693