Calibration of a portal imaging device for high-precision dosimetry: A Monte Carlo study

被引:23
作者
Keller, H [1 ]
Fix, M [1 ]
Ruegsegger, P [1 ]
机构
[1] ETH Zurich, Inst Biomed Engn, Zurich, Switzerland
关键词
electronic portal imaging; liquid filled ionization chambers; dose calibration; Monte Carlo simulation;
D O I
10.1118/1.598378
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Today electronic portal imaging devices (EPID's) are used primarily to verify patient positioning. They have, however, also the potential as 2D-dosimeters and could be used as such for transit dosimetry or dose reconstruction. It has been proven that such devices, especially liquid filled ionization chambers, have a stable dose response relationship which can be described in terms of the physical properties of the EPID and the pulsed linac radiation. For absolute dosimetry however, an accurate method of calibration to an absolute dose is needed. In this work, we concentrate on calibration against dose in a homogeneous water phantom. Using a Monte Carlo model of the detector we calculated dose spread kernels in units of absolute dose per incident energy fluence and compared them to calculated dose spread kernels in water at different depths. The energy of the incident pencil beams varied between 0.5 and 18 MeV. At the depth of dose maximum in water for a 6 MV beam (1.5 cm) and for a Is MV beam (3.0 cm) we observed large absolute differences between water and detector dose above an incident energy of 4 MeV but only small relative differences in the most frequent energy range of the beam energy spectra. It is shown that for a 6 MV beam the absolute reference dose measured at 1.5 cm water depth differs from the absolute detector dose by 3.8%. At depth 1.2 cm in water, however, the relative dose differences are almost constant between 2 and 6 MeV. The effects of changes in the energy spectrum of the beam on the dose responses in water and in the detector are also investigated. We show that differences larger than 2% can occur for different beam qualities of the incident photon beam behind water slabs of different thicknesses. It is therefore concluded that for high-precision dosimetry such effects have to be taken into account. Nevertheless, the precise information about the dose response of the detector provided in this Monte Carlo study forms the basis of extracting directly the basic radiometric quantities photon fluence and photon energy fluence from the detector's signal using a deconvolution algorithm. The results are therefore promising for future application in absolute transit dosimetry and absolute dose reconstruction. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)02210-X].
引用
收藏
页码:1891 / 1902
页数:12
相关论文
共 31 条
  • [1] APPLICATION OF THE CONVOLUTION METHOD FOR CALCULATION OF OUTPUT FACTORS FOR THERAPY PHOTON BEAMS
    AHNESJO, A
    KNOOS, T
    MONTELIUS, A
    [J]. MEDICAL PHYSICS, 1992, 19 (02) : 295 - 301
  • [2] The dose response relationship of a liquid-filled electronic portal imaging device
    Boellaard, R
    vanHerk, M
    Mijnheer, BJ
    [J]. MEDICAL PHYSICS, 1996, 23 (09) : 1601 - 1611
  • [3] A convolution model to convert transmission dose images to exit dose distributions
    Boellaard, R
    vanHerk, M
    Mijnheer, BJ
    [J]. MEDICAL PHYSICS, 1997, 24 (02) : 189 - 199
  • [4] A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS)
    BOYER, AL
    ANTONUK, L
    FENSTER, A
    VANHERK, M
    MEERTENS, H
    MUNRO, P
    REINSTEIN, LE
    WONG, J
    [J]. MEDICAL PHYSICS, 1992, 19 (01) : 1 - 16
  • [5] Experimental determination of the dose kernel in high-energy x-ray beams
    Ceberg, CP
    Bjarngard, BE
    Zhu, TC
    [J]. MEDICAL PHYSICS, 1996, 23 (04) : 505 - 511
  • [6] A LIQUID IONIZATION-CHAMBER FOR NEUTRON DOSIMETRY
    CHU, JCH
    GRANT, WH
    ALMOND, PR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (06) : 1133 - 1148
  • [7] EXTRACTION OF PENCIL BEAM KERNELS BY THE DECONVOLUTION METHOD
    CHUI, CS
    MOHAN, R
    [J]. MEDICAL PHYSICS, 1988, 15 (02) : 138 - 144
  • [8] DOSE CALCULATION FOR PHOTON BEAMS WITH INTENSITY MODULATION GENERATED BY DYNAMIC JAW OR MULTILEAF COLLIMATIONS
    CHUI, CS
    LOSASSO, T
    SPIROU, S
    [J]. MEDICAL PHYSICS, 1994, 21 (08) : 1237 - 1244
  • [9] Debye P., 1942, T ELECTROCHEM SOC, V82, P265, DOI [DOI 10.1149/1.3071413, 10.1149/1.3071413]
  • [10] EGLI P, 1998, Z MED PHYS, V8, P20