Accurate active islanding detection method for grid-tied inverters in distributed generation

被引:43
作者
Bei, Tai-Zhou [1 ]
机构
[1] State Grid Jinan Power Supply Co, 238 Luoyuan St, Jinan, Shandong, Peoples R China
关键词
distributed power generation; power distribution faults; invertors; power supply quality; integrating circuits; accurate active islanding detection method; grid-tied inverters; distributed generation; phase disturbance coefficient; grid synchronisation; power quality; third-harmonic component; multiple second-order generalised integrators; selective harmonic extraction; MATLAB; Simulink platform; LOCKED-LOOP; PLL; SYNCHRONIZATION; PERFORMANCE; PROTECTION; RELAYS; SCHEME; ROCOF;
D O I
10.1049/iet-rpg.2017.0080
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An accurate active islanding detection method for grid-tied inverters in distributed generation using phase disturbance based on grid synchronisation is presented in this study. To have good performance on both power quality and islanding detection, a third-harmonic injection is generated by a new kind of phase disturbance and the scope of phase disturbance coefficient is precisely defined, besides, for extracting the third-harmonic component at the point of common coupling accurately, a selective harmonic extraction based on multiple second-order generalised integrators is also provided. Performances of the proposed method have been studied and confirmed through extensive simulations using MATLAB/Simulink platform.
引用
收藏
页码:1633 / 1639
页数:7
相关论文
共 36 条
[1]  
[Anonymous], 2003, IEEE Std. 1547-2003, P1, DOI 10.1109/IEEESTD.2003.94285
[2]  
[Anonymous], 2002, T509 IEAPVPS
[3]  
[Anonymous], P PHOT SPEC C
[4]  
[Anonymous], 2004, IEEE PES M
[5]  
[Anonymous], 9292000 IEEE, DOI DOI 10.1109/IEEESTD.2000.91304.3024
[6]   An Islanding Detection Method Based on Dual-Frequency Harmonic Current Injection Under Grid Impedance Unbalanced Condition [J].
Cai, Wen ;
Liu, Bangyin ;
Duan, Shanxu ;
Zou, Changyue .
IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2013, 9 (02) :1178-1187
[7]   Accurate and Less-Disturbing Active Antiislanding Method Based on PLL for Grid-Connected Converters [J].
Ciobotaru, Mihai ;
Agelidis, Vassilios G. ;
Teodorescu, Remus ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (06) :1576-1584
[8]   Performance analysis of a new fast negative sequence power injection oriented islanding detection technique for photovoltaic photovoltaic based voltage source converter based micro grid operation [J].
Dhar, Snehamoy ;
Dash, Pradipta Kishore .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (15) :2079-2090
[9]   Active Islanding Detection Using High-Frequency Signal Injection [J].
Diaz Reigosa, David ;
Briz, Fernando ;
Blanco Charro, Cristian ;
Garcia, Pablo ;
Manuel Guerrero, Juan .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2012, 48 (05) :1588-1597
[10]   Robust phase locked-loop algorithm for single-phase utility-interactive inverters [J].
Elrayyah, Ali ;
Sozer, Yilmaz ;
Elbuluk, Malik .
IET POWER ELECTRONICS, 2014, 7 (05) :1064-1072