Mechanical behavior of locally corroded circular steel tube under compression

被引:23
作者
Wei, Yuan [1 ]
Wu, Zhaoqi [1 ]
Wang, Xintao [2 ]
Jiang, Shao-Fei [1 ]
机构
[1] Fuzhou Univ, Coll Civil Engn, Fuzhou 350108, Peoples R China
[2] Fujian Post & Telecom Planning & Design Inst Co L, Fuzhou 350001, Peoples R China
关键词
Circular steel tube; Localized corrosion; Orthogonal test; Compression; Numerical simulation; Load carrying capacity; Localized corrosion mode; CFST STUB COLUMNS; COMBINED SUSTAINED LOAD; BEAM-COLUMNS; RELIABILITY ASSESSMENT; PITTING CORROSION; ACTIVE CORROSION; PIPELINES; STRENGTH; CAPACITY; STRESS;
D O I
10.1016/j.istruc.2021.04.063
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Localized corrosion often occurs on steel members due to paint peeling led from insufficient durability of the coating material or human collision, which may significantly reduce the load carrying capacity and safety performance of the structures. The effects of the parameters such as localized corrosion penetration, circumferential corrosion ratio, longitudinal corrosion ratio, slenderness ratio and eccentricity of mechanical behaviors of locally corroded circular steel tubes under compression were studied experimentally and numerically. Based on the test results and the finite element analysis, a calculation method was proposed for predicting load carrying capacity of the corroded specimen under compression. It is found that localized corrosion did not change the failure modes of test specimens, and all of them failed in the limit point buckling mode. The factors affecting the degradation of load carrying capacity and stiffness of localized corrosion specimens from high to low were corrosion time, circumferential corrosion ratio and longitudinal corrosion ratio. The most unfavorable localized corrosion modes of load carrying capacity and stiffness were H3L3-270 and H3L1-270, respectively. The load carrying capacity degradation of members increases with the increase of the localized corrosion ratio, circumferential corrosion ratio and longitudinal corrosion ratio, while decreases with the increase of the eccentricity. The formula proposed can be used to predict the load carrying capacity of locally corroded circular steel tube members under compression.
引用
收藏
页码:776 / 791
页数:16
相关论文
共 47 条
[1]   Reliability assessment of underground pipelines under the combined effect of active corrosion and residual stress [J].
Amirat, A ;
Mohamed-Chateauneuf, A ;
Chaoui, K .
INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2006, 83 (02) :107-117
[2]   Compression strength of corroded steel angle members [J].
Beaulieu, L. -V. ;
Legeron, F. ;
Langlois, S. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (11) :1366-1373
[3]   A study on the reliability assessment methodology for pipelines with active corrosion defects [J].
Caleyo, F ;
González, JL ;
Hallen, JM .
INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2002, 79 (01) :77-86
[4]   Behaviors of axially loaded circular concrete-filled steel tube (CFT) stub columns with notch in steel tubes [J].
Chang, Xu ;
Fu, Lei ;
Zhao, Hong-Bo ;
Zhang, Yong-Bin .
THIN-WALLED STRUCTURES, 2013, 73 :273-280
[5]   Effect of corrosion on thin-walled pipes under combined internal pressure and bending [J].
Chegeni, Behrouz ;
Jayasuriya, Sachith ;
Das, Sreekanta .
THIN-WALLED STRUCTURES, 2019, 143
[6]   Compressive strength of corroded special-shaped welded hollow spherical joints based on numerical simulation [J].
Chen, Huiyun ;
Liu, Hongbo ;
Chen, Zhihua .
THIN-WALLED STRUCTURES, 2020, 149
[7]  
Chen TP., 2016, EXPT STUDY FINITE EL
[8]   Ratcheting behavior of pressurized corroded straight pipe subjected to cyclic bending [J].
Chen, Xiaohui ;
Chen, Haofeng ;
Zhao, Li .
THIN-WALLED STRUCTURES, 2019, 145
[9]   Behaviors of axially loaded square concrete-filled steel tube (CFST) Stub columns with notch in steel tube [J].
Ding, Fa-xing ;
Fu, Lei ;
Yu, Zhi-wu .
THIN-WALLED STRUCTURES, 2017, 115 :196-204
[10]   CFRP strengthening and rehabilitation of corroded steel pipelines under direct indentation [J].
Elchalakani, Mohamed ;
Karrech, Ali ;
Basarir, Hakan ;
Hassanein, M. F. ;
Fawzia, Sabrina .
THIN-WALLED STRUCTURES, 2017, 119 :510-521