Efficacy and safety data for the Ab interno XEN45 gel stent implant at 3 Years: A retrospective analysis

被引:21
|
作者
Gabbay, Itay E. [1 ,2 ,3 ]
Goldberg, Mordechai [1 ]
Allen, Felicity [1 ]
Lin, Zhiheng [1 ]
Morley, Christine [1 ]
Pearsall, Tahmina [4 ]
Muraleedharan, Veena [1 ]
Ruben, Simon [1 ]
机构
[1] Mid & South Essex NHS Fdn Trust, Dept Ophthalmol, Southend On Sea, England
[2] Beilinson Med Ctr, Rabin Med Ctr, Petah Tiqwa, Israel
[3] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[4] Whipps Cross Univ Hosp, Barts Hlth NHS Trust, London, England
关键词
XEN; glaucoma; minimally invasive; open angle; surgery; OPEN-ANGLE GLAUCOMA; INTRAOCULAR-PRESSURE; SURGICAL-TREATMENT; SURGERY; PHACOEMULSIFICATION; VISCODILATION; MICROSTENT; REDUCTION; CATARACT; OUTCOMES;
D O I
10.1177/11206721211014381
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report efficacy and safety measures of the XEN45 gel stent at 36 months in the UK National Health Service setting. Methods: Retrospective non-comparative audit of the records of patients who underwent XEN45 implantation between June 2015 and May 2017 was performed. Main outcome measures were intraocular pressure and number of antihypertensive medications used. Failure was defined as need for further surgery or stent removal. Success was defined as a 20% decrease in intraocular pressure without the need for additional glaucoma medications or a reduction in antihypertensive medications without an increase in baseline intraocular pressure. Needling rates and preoperative factors effect were assessed. Results: The cohort included 205 patients (205 eyes) with primary open angle glaucoma (84.4%), angle closure glaucoma (7.8%), or refractory glaucoma (7.8%), 62.9% had a stand-alone procedure and 37.1%, a combined phaco-XEN45 procedure. Mean intraocular pressure was 22.6 +/- 7.0 mmHg at baseline compared to 14.7 +/- 3.8 mmHg at 24 months and 14.0 +/- 2.9 mmHg at 36 months (p < 0.001 for both). Mean number of medications used was 2.6 +/- 1.1 at baseline compared to 0.5 +/- 0.9 and 0.6 +/- 1.0, at 24- and 36-months, respectively (p < 0.001 for both). The failure rate at 36 months was 25%. Needling was required in 36.6%. Evaluation of background factors yielded an increased failure rate in non-Caucasians compared to Caucasians (74% vs 21%, p < 0.001). Conclusion: XEN45 implantation is effective and safe at 36 months' follow-up. Patients should be advised regarding the risk of failure and possible need for bleb revisions. Careful patient selection may be required.
引用
收藏
页码:1016 / 1022
页数:7
相关论文
共 41 条
  • [31] Long-term efficacy and safety of XEN-45 gel stent implantation in patients with normal-tension glaucoma
    Nasyrov, Emil
    Gassel, Caroline J.
    Merle, David A.
    Neubauer, Jonas
    Voykov, Bogomil
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [32] Recanalization of Xen45 gel stent implant occlusion using 10-0 nylon suture in refractory glaucoma: a case report
    Zhang, Yao
    Xiang, Haotian
    Zhang, Yangyang
    Tang, Li
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [33] Standalone XEN45 Gel Stent implantation versus combined XEN45-phacoemulsification in the treatment of open angle glaucoma—a systematic review and meta-analysis
    Sheng Yang Lim
    Bjorn Kaijun Betzler
    Leonard Wei Leon Yip
    Syril Dorairaj
    Bryan Chin Hou Ang
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 3209 - 3219
  • [34] Complications and post-operative interventions in XEN45 gel stent implantation in the treatment of open angle glaucoma-a systematic review and meta-analysis
    Betzler, Bjorn Kaijun
    Lim, Sheng Yang
    Lim, Boon Ang
    Yip, Vivien Cherng Hui
    Ang, Bryan Chin Hou
    EYE, 2023, 37 (06) : 1047 - 1060
  • [35] Recanalization of Xen45 gel stent implant occlusion using 10 − 0 nylon suture in refractory glaucoma: a case report
    Yao Zhang
    Haotian Xiang
    Yangyang Zhang
    Li Tang
    BMC Ophthalmology, 23
  • [36] Effectiveness and safety of the XEN45 gel stent compared to trabeculectomy in primary open-angle glaucoma: the Gold-Standard Pathway Study
    Ahmed, Iqbal K.
    Vera, Vanessa
    Stalmans, Ingeborg
    Fea, Antonio Maria
    Mansouri, Kaweh
    Gu, Xuemin
    Craven, Earl Randy
    Reitsamer, Herbert A.
    BMJ OPEN OPHTHALMOLOGY, 2025, 10 (01):
  • [37] One year efficacy and safety of inferior implantation of Xen 45® Gel Stent in refractory glaucoma
    Bastelica, P.
    Amatu, J. -B.
    Buffault, J.
    Majoulet, A.
    Labbe, A.
    Baudouin, C.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2024, 47 (08):
  • [38] Efficacy and safety of XEN 45 gel stent alone or in combination with phacoemulsification in advanced open angle glaucoma patients: 1-year retrospective study
    Teresa Laborda-Guirao
    Juan M Cubero-Parra
    Antonio Hidalgo-Torres
    International Journal of Ophthalmology, 2020, (08) : 1250 - 1256
  • [39] A Retrospective Analysis of Safety and Efficacy of XEN 45 Microstent Combined Cataract Surgery in Open-Angle Glaucoma over 24 Months
    Subasi, Sevgi
    Yuksel, Nursen
    Ozer, Fevzi
    Tugan, Busra Yilmaz
    Pirhan, Dilara
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2021, 51 (03): : 139 - 145
  • [40] Posture-induced changes in intraocular pressure after ab externo XEN45 gel-stent implantation in patients with primary open-angle glaucoma
    Jin, Hyung Nam
    Nam, Jeong Woo
    Zhang, Haowei
    Sung, Mi Sun
    Park, Sang Woo
    BMC OPHTHALMOLOGY, 2022, 22 (01)