Efficacy and safety data for the Ab interno XEN45 gel stent implant at 3 Years: A retrospective analysis

被引:21
|
作者
Gabbay, Itay E. [1 ,2 ,3 ]
Goldberg, Mordechai [1 ]
Allen, Felicity [1 ]
Lin, Zhiheng [1 ]
Morley, Christine [1 ]
Pearsall, Tahmina [4 ]
Muraleedharan, Veena [1 ]
Ruben, Simon [1 ]
机构
[1] Mid & South Essex NHS Fdn Trust, Dept Ophthalmol, Southend On Sea, England
[2] Beilinson Med Ctr, Rabin Med Ctr, Petah Tiqwa, Israel
[3] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[4] Whipps Cross Univ Hosp, Barts Hlth NHS Trust, London, England
关键词
XEN; glaucoma; minimally invasive; open angle; surgery; OPEN-ANGLE GLAUCOMA; INTRAOCULAR-PRESSURE; SURGICAL-TREATMENT; SURGERY; PHACOEMULSIFICATION; VISCODILATION; MICROSTENT; REDUCTION; CATARACT; OUTCOMES;
D O I
10.1177/11206721211014381
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report efficacy and safety measures of the XEN45 gel stent at 36 months in the UK National Health Service setting. Methods: Retrospective non-comparative audit of the records of patients who underwent XEN45 implantation between June 2015 and May 2017 was performed. Main outcome measures were intraocular pressure and number of antihypertensive medications used. Failure was defined as need for further surgery or stent removal. Success was defined as a 20% decrease in intraocular pressure without the need for additional glaucoma medications or a reduction in antihypertensive medications without an increase in baseline intraocular pressure. Needling rates and preoperative factors effect were assessed. Results: The cohort included 205 patients (205 eyes) with primary open angle glaucoma (84.4%), angle closure glaucoma (7.8%), or refractory glaucoma (7.8%), 62.9% had a stand-alone procedure and 37.1%, a combined phaco-XEN45 procedure. Mean intraocular pressure was 22.6 +/- 7.0 mmHg at baseline compared to 14.7 +/- 3.8 mmHg at 24 months and 14.0 +/- 2.9 mmHg at 36 months (p < 0.001 for both). Mean number of medications used was 2.6 +/- 1.1 at baseline compared to 0.5 +/- 0.9 and 0.6 +/- 1.0, at 24- and 36-months, respectively (p < 0.001 for both). The failure rate at 36 months was 25%. Needling was required in 36.6%. Evaluation of background factors yielded an increased failure rate in non-Caucasians compared to Caucasians (74% vs 21%, p < 0.001). Conclusion: XEN45 implantation is effective and safe at 36 months' follow-up. Patients should be advised regarding the risk of failure and possible need for bleb revisions. Careful patient selection may be required.
引用
收藏
页码:1016 / 1022
页数:7
相关论文
共 41 条
  • [21] Five-year outcomes of ab interno Xen 45 gel stent implantation
    Ansari, Ejaz
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (04) : 1263 - 1269
  • [22] Standalone XEN45 Gel Stent implantation in the treatment of open-angle glaucoma: A systematic review and meta-analysis
    Lim, Sheng Yang
    Betzler, Bjorn Kaijun
    Yip, Leonard Wei Leon
    Dorairaj, Syril
    Ang, Bryan Chin Hou
    SURVEY OF OPHTHALMOLOGY, 2022, 67 (04) : 1048 - 1061
  • [23] Effectiveness and safety of XEN45 implant over 12 months of follow-up: data from the XEN-Glaucoma Treatment Registry
    Oddone, Francesco
    Roberti, Gloria
    Giammaria, Sara
    Posarelli, Chiara
    Ghirelli, Giorgio
    Mastropasqua, Leonardo
    Agnifili, Luca
    Micelli Ferrari, Tommaso
    Pace, Vincenzo
    Nucci, Paolo
    Sacchi, Matteo
    Monsellato, Gianluca
    Altafini, Romeo
    Scuderi, Gianluca
    Perdicchi, Andrea
    Uva, Maurizio
    Carnevale, Carmela
    Covello, Giuseppe
    Maglionico, Maria Novella
    Fea, Antonio
    Figus, Michele
    EYE, 2024, 38 (01) : 103 - 111
  • [24] Standalone XEN45 Gel Stent implantation versus combined XEN45-phacoemulsification in the treatment of open angle glaucoma-a systematic review and meta-analysis
    Lim, Sheng Yang
    Betzler, Bjorn Kaijun
    Yip, Leonard Wei Leon
    Dorairaj, Syril
    Ang, Bryan Chin Hou
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (11) : 3209 - 3219
  • [25] Outcomes of XEN45 gel stent using posterior small incision sub-tenon ab interno insertion (Semi-open) technique
    Kong, Yu Xiang George
    Chung, In Young
    Ang, Ghee Soon
    EYE, 2022, 36 (07) : 1456 - 1460
  • [26] Interim Analysis of Clinical Outcomes with Open versus Closed Conjunctival Implantation of the XEN45 Gel Stent
    McGlumphy, Elyse J.
    Do, Anna
    Du, Amy
    Craven, Earl Randy
    Geyman, Lawrence S.
    Shen, Leo
    Schuman, Joel S.
    Panarelli, Joseph F.
    OPHTHALMOLOGY GLAUCOMA, 2024, 7 (02): : 116 - 122
  • [27] Efficacy and safety of XEN 45 gel stent alone or in combination with phacoemulsification in advanced open angle glaucoma patients: 1-year retrospective study
    Laborda-Guirao, Teresa
    Cubero-Parra, Juan M.
    Hidalgo-Torres, Antonio
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (08) : 1250 - 1256
  • [28] Safety and efficacy outcomes of the Xen45 Gel Stent use for refractory glaucoma: a surgery series from surgeon trainees at a tertiary teaching hospital
    Hong, Karen
    Lind, John
    Sheybani, Arsham
    EYE AND VISION, 2020, 7 (01)
  • [29] Safety and efficacy outcomes of the Xen45 Gel Stent use for refractory glaucoma: a surgery series from surgeon trainees at a tertiary teaching hospital
    Karen Hong
    John Lind
    Arsham Sheybani
    Eye and Vision, 7
  • [30] Real-world retrospective consecutive study of ab interno XEN 45 gel stent implant with mitomycin C in black and afro-latino patients with glaucoma: 40% required secondary glaucoma surgery at 1 year
    Laroche, Daniel
    Nkrumah, Gideon
    Ng, Chester
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2019, 26 (04) : 229 - 234