Can CT scan protocols used for radiotherapy treatment planning be adjusted to optimize image quality and patient dose? A systematic review

被引:72
作者
Davis, Anne T. [1 ,2 ]
Palmer, Antony L. [1 ,2 ]
Nisbet, Andrew [1 ,3 ]
机构
[1] Univ Surrey, Fac Engn & Phys Sci, Dept Phys, Guildford, Surrey, England
[2] Portsmouth Hosp NHS Trust, Dept Med Phys, Portsmouth, Hants, England
[3] Royal Surrey Cty Hosp NHS Fdn Trust, Dept Med Phys, Guildford, Surrey, England
关键词
COMPUTED-TOMOGRAPHY NUMBER; DIGITALLY RECONSTRUCTED RADIOGRAPHS; TARGET VOLUME DELINEATION; RADIATION-THERAPY; ELECTRON-DENSITY; HOUNSFIELD UNITS; ITERATIVE RECONSTRUCTION; ATOMIC NUMBERS; VARIABILITY; CALIBRATION;
D O I
10.1259/bjr.20160406
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article reviews publications related to the use of CT scans for radiotherapy treatment planning, specifically the impact of scan protocol changes on CT number and treatment planning dosimetry and on CT image quality. A search on PubMed and EMBASE and a subsequent review of references yielded 53 relevant articles. CT scan parameters significantly affect image quality. Some will also affect Hounsfield unit (HU) values, though this is not comprehensively reported on. Changes in tube kilovoltage and, on some scanners, field of view and reconstruction algorithms have been found to produce notable HU changes. The degree of HU change which can be tolerated without changing planning dose by > 1% depends on the body region and size, planning algorithms, treatment beam energy and type of plan. A change in soft-tissue HU value has a greater impact than changes in HU for bone and air. The use of anthropomorphic phantoms is recommended when assessing HU changes. There is limited published work on CT scan protocol optimization in radiotherapy. Publications suggest that HU tolerances of +/- 20 HU for soft tissue and of +/- 50 HU for the lung and bone would restrict dose changes in the treatment plan to < 1%. Literature related to the use of CT images in radiotherapy planning has been reviewed to establish the acceptable level of HU change and the impact on image quality of scan protocol adjustment. Conclusions have been presented and further work identified.
引用
收藏
页数:10
相关论文
共 76 条
[1]   Dose calculations for external photon beams in radiotherapy [J].
Ahnesjö, A ;
Aspradakis, MM .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :R99-R155
[2]  
American Association of Physicists in Medicine Task Group, 2004, 85 AM ASS PHYS MED T
[3]  
[Anonymous], 2012, IAEA HUM HLTH SER
[4]  
[Anonymous], 16262 EUR EN
[5]  
[Anonymous], 2005, MHRA EV REP MHRA 050
[6]  
[Anonymous], 2014, KHANS PHYS RAD THERA
[7]  
[Anonymous], 2004, MHRA EV REP MHRA 054
[8]  
[Anonymous], 2004, MHRA EV REP MHRA 040
[9]   Dosimetric comparison of different inhomogeneity correction algorithms for external photon beam dose calculations [J].
Asnaashari, Khadijeh ;
Nodehi, Mohammad Rasa Golrokh ;
Mahdavi, Seyyed Rabie ;
Gholami, Somaye ;
Khosravi, Hamid Reza .
JOURNAL OF MEDICAL PHYSICS, 2013, 38 (02) :74-81
[10]   An assessment of image distortion and CT number accuracy within a wide-bore CT extended field of view [J].
Beeksma, B. ;
Truant, D. ;
Holloway, L. ;
Arumugam, S. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (02) :255-261