The Nuclear Medicine Patient as a Line Source: The Source Length Is Certainly Not the Patient Height, But It Is a Reasonable Approximation

被引:3
作者
Broggio, David [1 ]
机构
[1] Inst Radioprotect & Surete Nucl, IRSN PSE SANTE SDOS LEDI, BP 17, Fontenay Aux Roses, France
来源
HEALTH PHYSICS | 2022年 / 123卷 / 03期
关键词
dose; external; exposure; population; nuclear medicine; radiation; medical; RADIATION-DOSE RATES; RECEIVING I-131 THERAPY; THYROID-CANCER; RADIOACTIVE PATIENTS; RADIOIODINE THERAPY; SAFETY PRECAUTIONS; RELEASE CRITERIA; ADULT PATIENTS; EXPOSURE; POINT;
D O I
10.1097/HP.0000000000001587
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Nuclear medicine patients are a source of exposure and should receive instructions to restrict contact time with different categories of people. The calculation of the restriction time requires that the dose rate at a given distance, known from an initial measurement and a whole-body retention function, can be extrapolated at other distances. As a basis for this extrapolation, it has been suggested to consider the patient as a line source. However, the validity of this suggestion is based on a few studies and limited measurement distances. We collected from the literature dose rates of nuclear medicine patients measured at different distances and investigated the robustness of the line source model. The cases of F-18-FDG exams, Tc-99m bone scan exams, and I-131 for hyperthyroidism treatment and remnants ablation were considered. The data were pooled, different cases of measurement time after administration were considered, and the data were fitted according to the line source model in which the half patient thickness was introduced. It was found that the line source model fits well the data put with a source length that is radionuclide-specific and significantly different from the standard adult height. However, considering a standard source length of 176 cm and neglecting the patient thickness induced at maximum an overestimation by a factor of 2.5 when extrapolating from 1 m to 10 cm. Such an overestimation is not of considerable importance in the calculation of contact restriction times.
引用
收藏
页码:208 / 217
页数:10
相关论文
共 68 条
[1]  
Abe R., 2010, IAEA
[2]   Estimation of Radiation Exposure to Workers During [18F] FDG PET/CT Procedures at Molecular Imaging Center, Oman [J].
Al-Aamria, Marwa ;
AL-Balushia, Naima ;
Bailey, Dale .
JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2019, 50 (04) :565-570
[3]   Patient parameters and other radiation safety issues in 131I therapy for thyroid cancer treatment [J].
Al-Haj, Abdalla N. ;
Lagarde, Charlie S. ;
Lobriguito, Aida M. .
HEALTH PHYSICS, 2007, 93 (06) :656-666
[4]  
Andreas D, 2014, Radiogr Open, V1, P11, DOI DOI 10.7577/RADOPEN.1196
[5]  
[Anonymous], 2009, IAEA SAF REP SER
[6]   Radiation dose rates from patients receiving iodine-131 therapy for carcinoma of the thyroid [J].
Barrington, SF ;
Kettle, AG ;
ODoherty, MJ ;
Wells, CP ;
Somer, EJR ;
Coakley, AJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (02) :123-130
[7]   Estimated dose from diagnostic nuclear medicine patients to people outside the Nuclear Medicine department [J].
Bartlett, Marissa L. .
RADIATION PROTECTION DOSIMETRY, 2013, 157 (01) :44-52
[8]   Radiation dose rates from patients undergoing PET: implications for technologists and waiting areas [J].
Benatar, NA ;
Cronin, BF ;
O'Doherty, MJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (05) :583-589
[9]  
Berg GEB, 1996, J NUCL MED, V37, P228
[10]  
Carlier T., 2004, Radioprotection, V39, P481, DOI 10.1051/radiopro:2004012