Fast three dimensional ac electro-osmotic pumps with nonphotolithographic electrode patterning

被引:13
作者
Senousy, Y. M. [1 ]
Harnett, C. K. [1 ]
机构
[1] Univ Louisville, Louisville, KY 40208 USA
来源
BIOMICROFLUIDICS | 2010年 / 4卷 / 03期
基金
美国国家科学基金会;
关键词
biological techniques; bioMEMS; electrodes; electrophoresis; microfabrication; microfluidics; micropumps; osmosis; FLOW;
D O I
10.1063/1.3463719
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Three dimensional (3D) stepped electrodes dramatically improve the flow rate and frequency range of ac electro-osmotic pumps, compared to planar electrodes. However, the fabrication of 3D stepped electrodes for ac electro-osmosis (ACEO) pumps usually involves several processing steps. This paper demonstrates results from ACEO pumps produced by a faster and less expensive method to fabricate the 3D electrodes-extending the previous work to disposable devices. The method is based on shadowed evaporation of metal on an insulating substrate that can be injection molded. Flow velocities through the 3D ACEO pump are similar to those seen in the previous work. (C) 2010 American Institute of Physics. [doi: 10.1063/1.3463719]
引用
收藏
页数:7
相关论文
共 13 条
  • [1] Theoretical prediction of fast 3D AC electro-osmotic pumps
    Bazant, Martin Z.
    Ben, Yuxing
    [J]. LAB ON A CHIP, 2006, 6 (11) : 1455 - 1461
  • [2] Induced-charge electrokinetic phenomena
    Bazant, Martin Z.
    Squires, Todd M.
    [J]. CURRENT OPINION IN COLLOID & INTERFACE SCIENCE, 2010, 15 (03) : 203 - 213
  • [3] Towards an understanding of induced-charge electrokinetics at large applied voltages in concentrated solutions
    Bazant, Martin Z.
    Kilic, Mustafa Sabri
    Storey, Brian D.
    Ajdari, Armand
    [J]. ADVANCES IN COLLOID AND INTERFACE SCIENCE, 2009, 152 (1-2) : 48 - 88
  • [4] Pumping of water with ac electric fields applied to asymmetric pairs of microelectrodes
    Brown, ABD
    Smith, CG
    Rennie, AR
    [J]. PHYSICAL REVIEW E, 2001, 63 (01):
  • [5] Fabrication of microfluidic devices using polydimethylsiloxane
    Friend, James
    Yeo, Leslie
    [J]. BIOMICROFLUIDICS, 2010, 4 (02):
  • [6] GERWEN PV, 2000, J MICROMECH MICROENG, V10, P5
  • [7] Ultrafast high-pressure AC electro-osmotic pumps for portable biomedical microfluidics
    Huang, Chien-Chih
    Bazant, Martin Z.
    Thorsen, Todd
    [J]. LAB ON A CHIP, 2010, 10 (01) : 80 - 85
  • [8] AC electric-field-induced fluid flow in microelectrodes
    Ramos, A
    Morgan, H
    Green, NG
    Castellanos, A
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1999, 217 (02) : 420 - 422
  • [9] Pressure-driven flow control system for nanofluidic chemical process
    Tamaki, Eiichiro
    Hibara, Akihide
    Kim, Haeng-Boo
    Tokeshi, Manabu
    Kitamori, Takehiko
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1137 (02) : 256 - 262
  • [10] The effect of step height on the performance of three-dimensional ac electro-osmotic microfluidic pumps
    Urbanski, John Paul
    Levitan, Jeremy A.
    Burch, Damian N.
    Thorsen, Todd
    Bazant, Martin Z.
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2007, 309 (02) : 332 - 341