Accuracy of 3D cephalometric measurements based on an automatic knowledge-based landmark detection algorithm

被引:56
作者
Gupta, Abhishek [1 ,2 ]
Kharbanda, Om Prakash [3 ]
Sardana, Viren [2 ]
Balachandran, Rajiv [3 ]
Sardana, Harish Kumar [1 ,2 ]
机构
[1] Acad Sci & Innovat Res AcSIR, New Delhi, India
[2] Cent Sci Instruments Org, CSIR, Chandigarh 160030, India
[3] All India Inst Med Sci, Ctr Dent Educ & Res, New Delhi 110029, India
关键词
3D cephalometry; Automatic landmarking; Knowledge-based detection; CBCT; Cephalometric analysis; BEAM COMPUTED-TOMOGRAPHY; RELIABILITY; IDENTIFICATION; REPRODUCIBILITY; IMAGES; PRECISION;
D O I
10.1007/s11548-015-1334-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To evaluate the accuracy of three-dimensional cephalometric measurements obtained through an automatic landmark detection algorithm compared to those obtained through manual identification. The study demonstrates a comparison of 51 cephalometric measurements (28 linear, 16 angles and 7 ratios) on 30 CBCT (cone beam computed tomography) images. The analysis was performed to compare measurements based on 21 cephalometric landmarks detected automatically and those identified manually by three observers. Inter-observer ICC for each landmark was found to be excellent () among three observers. The unpaired t-test revealed that there was no statistically significant difference in the measurements based on automatically detected and manually identified landmarks. The difference between the manual and automatic observation for each measurement was reported as an error. The highest mean error in the linear and angular measurements was found to be 2.63 mm ( distance) and (-Me angle), respectively. The highest mean error in the group of distance ratios was 0.03 (for N-Me/N-ANS and ). Cephalometric measurements computed from automatic detection of landmarks on 3D CBCT image were as accurate as those computed from manual identification.
引用
收藏
页码:1297 / 1309
页数:13
相关论文
共 40 条
[1]  
[Anonymous], EUR J DENT
[2]  
[Anonymous], 2005, 3 DIMENSIONAL CEPHAL
[3]  
[Anonymous], 2009, ORTHODONTICS DIAGNOS
[4]  
[Anonymous], ANGLE ORTHOD
[5]  
[Anonymous], 3 DIMENSIONAL CEPHAL
[6]   RELIABILITY OF HEAD FILM MEASUREMENTS .1. LANDMARK IDENTIFICATION [J].
BAUMRIND, S ;
FRANTZ, RC .
AMERICAN JOURNAL OF ORTHODONTICS, 1971, 60 (02) :111-&
[7]   New three-dimensional cephalometric analyses among adults with a skeletal Class I pattern and normal occlusion [J].
Bayome, Mohamed ;
Park, Jae-Hyun ;
Kook, Yoon-Ah .
KOREAN JOURNAL OF ORTHODONTICS, 2013, 43 (02) :62-73
[8]   Comparison of reliability in anatomical landmark identification using two-dimensional digital cephalometrics and three-dimensional cone beam computed tomography in vivo [J].
Chien, P. C. ;
Parks, E. T. ;
Eraso, F. ;
Hartsfield, J. K., Jr. ;
Roberts, W. E. ;
Ofner, S. .
DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (05) :262-273
[9]   Reliability and the smallest detectable difference of measurements on 3-dimensional cone-beam computed tomography images [J].
Damstra, Janalt ;
Fourie, Zacharias ;
Slater, James J. R. Huddleston ;
Ren, Yijin .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (03) :E107-E114
[10]   Observer reliability of three-dimensional cephalometric landmark identification on cone-beam computerized tomography [J].
de Oliveira, Ana Emilia F. ;
Cevidanes, Lucia Helena S. ;
Phillips, Ceib ;
Motta, Alexandre ;
Burke, Brandon ;
Tyndall, Donald .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (02) :256-265