A thiocoumarin-based colorimetric and ratiometric fluorescent probe for Hg2+ in aqueous solution and its application in live-cell imaging

被引:48
作者
Qin, Siyao [1 ]
Chen, Bo [1 ]
Huang, Jing [1 ]
Han, Yifeng [1 ]
机构
[1] Zhejiang Sci Tech Univ, Key Lab Adv Text Mat & Mfg Technol, Dept Chem, Hangzhou 310018, Zhejiang, Peoples R China
关键词
LIVING CELLS; MERCURY IONS; SELECTIVE DETECTION; HYDROGEN-SULFIDE; HYPOCHLOROUS ACID; HIGH-SENSITIVITY; RATIONAL DESIGN; FRET SYSTEM; RHODAMINE; CHEMODOSIMETER;
D O I
10.1039/c8nj01491d
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new intramolecular charge transfer (ICT) based colorimetric and ratiometric fluorescent chemodosimeter for the detection of Hg2+ has been rationally designed and developed. The probe operates via the specific mercury-promoted desulfurization reaction of thiocoumarin to coumarin and exhibits high selectivity and sensitivity in almost pure aqueous solution (containing only 1% DMSO) with a Low detection Limit of 1.85 ppb. Furthermore, the probe was successfully used for the fluorescence imaging of Hg2+ in Live cells.
引用
收藏
页码:12766 / 12772
页数:7
相关论文
共 77 条
[61]   Simultaneous determination of copper, cobalt, and mercury ions in water samples by solid-phase extraction using carbon nanotube sponges as adsorbent after chelating with sodium diethyldithiocarbamate prior to high performance liquid chromatography [J].
Wang, Lei ;
Zhou, Jia-Bin ;
Wang, Xia ;
Wang, Zhen-Hua ;
Zhao, Ru-Song .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (16) :4445-4453
[62]   A Highly Sensitive Ratiometric Fluorescent Probe for the Detection of Cytoplasmic and Nuclear Hydrogen Peroxide [J].
Wen, Ying ;
Liu, Keyin ;
Yang, Huiran ;
Li, Yi ;
Lan, Haichuang ;
Liu, Yi ;
Zhang, Xinyu ;
Yi, Tao .
ANALYTICAL CHEMISTRY, 2014, 86 (19) :9970-9976
[63]  
Wolfe MF, 1998, ENVIRON TOXICOL CHEM, V17, P146, DOI [10.1897/1551-5028(1998)017<0146:EOMOWA>2.3.CO
[64]  
2, 10.1002/etc.5620170203]
[65]   Fluorescent chemosensors: the past, present and future [J].
Wu, Di ;
Sedgwick, Adam C. ;
Gunnlaugsson, Thorfinnur ;
Akkaya, Engin U. ;
Yoon, Juyoung ;
James, Tony D. .
CHEMICAL SOCIETY REVIEWS, 2017, 46 (23) :7105-7123
[66]   Rational design of a ratiometric fluorescent probe with a large emission shift for the facile detection of Hg2+ [J].
Xuan, Weimin ;
Chen, Chen ;
Cao, Yanting ;
He, Wenhan ;
Jiang, Wei ;
Liu, Kejian ;
Wang, Wei .
CHEMICAL COMMUNICATIONS, 2012, 48 (58) :7292-7294
[67]   A NIR ratiometric probe for hydrazine "naked eye" detection and its imaging in living cell [J].
Yang, Xiaopeng ;
Liu, Yongxiang ;
Wu, Yuanyuan ;
Ren, Xueling ;
Zhang, Di ;
Ye, Yong .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 253 :488-494
[68]   Luminescent Chemodosimeters for Bioimaging [J].
Yang, Yuming ;
Zhao, Qiang ;
Feng, Wei ;
Li, Fuyou .
CHEMICAL REVIEWS, 2013, 113 (01) :192-270
[69]   A lysosome-targeted ratiometric fluorescent probe for detection of hypochlorous acid in living cells [J].
Yuan, Qiong ;
Zhao, Zhi-Min ;
Zhang, Yan-Ru ;
Su, Le ;
Miao, Jun-Ying ;
Zhao, Bao-Xiang .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 247 :736-741
[70]   Homocysteine and the renal epithelial transport and toxicity of inorganic mercury: Role of basolateral transporter organic anion transporter 1 [J].
Zalups, RK ;
Ahmad, S .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2004, 15 (08) :2023-2031