Evaluation of canine hepatic masses by use of triphasic computed tomography and B-mode, color flow, power, and pulsed-wave Doppler ultrasonography and correlation with histopathologic classification

被引:1
|
作者
Griebie, Erin R. [1 ,2 ]
David, Frederic H. [1 ]
Ober, Christopher P. [1 ]
Feeney, Daniel A. [1 ]
Anderson, Kari L. [1 ]
Wuenschmann, Arno [1 ]
Jessen, Carl R. [1 ]
机构
[1] Univ Minnesota, Coll Vet Med, Dept Vet Clin Sci, St Paul, MN 55108 USA
[2] Idexx Telemed, 9200 SE Sunnybrook Blvd,Ste 460, Clackamas, OR 97015 USA
关键词
FOCAL LIVER-LESIONS; HEPATOCELLULAR-CARCINOMA; TUMOR VASCULARITY; DYNAMIC CT; DOGS; ANGIOGRAPHY; ULTRASOUND; PHASE;
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
OBJECTIVE To determine clinical relevance for quantitative and qualitative features of canine hepatic masses evaluated by use of triphasic CT and B-mode, color flow, power, and pulsed-wave Doppler ultrasonography and to compare diagnostic accuracy of these modalities for predicting mass type on the basis of histopathologic classification. ANIMALS 44 client-owned dogs. PROCEDURES Dogs with histopathologic confirmation (needle core, punch, or excisional biopsy) of a hepatic mass were enrolled. Triphasic CT and B-mode, color flow, power, and pulsed-wave Doppler ultrasonography of each hepatic mass were performed. Seventy quantitative and qualitative variables of each hepatic mass were recorded by 5 separate observers and statistically evaluated with discriminant and stepwise analyses. Significant variables were entered in equation-based predictions for the histopathologic diagnosis. RESULTS An equation that included the lowest delayed-phase absolute enhancement of the mass and the highest venous-phase mass conspicuity was used to correctly classify 43 of 46 (93.5%) hepatic masses as benign or malignant. An equation that included only the lowest delayed-phase absolute enhancement of the mass could be used to correctly classify 42 of 46 (91.3%) masses (with expectation of malignancy if this value was < 37 Hounsfield units). For ultrasonography, categorization of the masses with cavitations as malignant achieved a diagnostic accuracy of 80.4%. CONCLUSIONS AND CLINICAL RELEVANCE Triphasic CT had a higher accuracy than ultrasonography for use in predicting hepatic lesion classification. The lowest delayed-phase absolute enhancement of the mass was a simple calculation that required 2 measurements and aided in the differentiation of benign versus malignant hepatic masses.
引用
收藏
页码:1273 / 1283
页数:11
相关论文
共 3 条
  • [1] Characterization of normal and abnormal canine superficial lymph nodes using gray-scale B-mode, color flow mapping, power, and spectral Doppler ultrasonography: A multivariate study
    Nyman, HT
    Kristensen, AT
    Skovgaard, IM
    McEvoy, FJ
    VETERINARY RADIOLOGY & ULTRASOUND, 2005, 46 (05) : 404 - 410
  • [2] B-mode and Doppler ultrasonography in the renal evaluation of dogs undergoing computed tomography after intravenous administration of different iodinated contrast media
    Martin, Claudia Matsunaga
    Kogika, Marcia Mery
    Miyashiro, Samantha Ive
    Brandao de Campos Fonseca-Pinto, Ana Carolina
    PESQUISA VETERINARIA BRASILEIRA, 2017, 37 (07): : 759 - 772
  • [3] Evaluation of Screening US-detected Breast Masses by Combined Use of Elastography and Color Doppler US with B-Mode US in Women with Dense Breasts: A Multicenter Prospective Study
    Lee, Su Hyun
    Chung, Jin
    Choi, Hye Young
    Choi, Seon Hyeong
    Ryu, Eun Bi
    Ko, Kyung Hee
    Koo, Hye Ryoung
    Park, Jeong Seon
    Yi, Ann
    Youk, Ji Hyun
    Son, Eun Ju
    Chu, A. Jung
    Chang, Jung Min
    Cho, Nariya
    Jang, Myoung-jin
    Kook, Shin Ho
    Cha, Eun Suk
    Moon, Woo Kyung
    RADIOLOGY, 2017, 285 (02) : 660 - 669