Partition model for estimating radiation doses from yttrium-90 microspheres in treating hepatic tumours

被引:245
作者
Ho, S
Lau, WY
Leung, TWT
Chan, M
Ngar, YK
Johnson, PJ
Li, AKC
机构
[1] CHINESE UNIV HONG KONG,PRINCE WALES HOSP,DEPT SURG,SHATIN,NEW TERR,HONG KONG
[2] CHINESE UNIV HONG KONG,PRINCE WALES HOSP,DEPT CLIN ONCOL,SHATIN,NEW TERR,HONG KONG
[3] CHINESE UNIV HONG KONG,PRINCE WALES HOSP,DEPT DIAGNOST RADIOL & ORGAN IMAGING,SHATIN,NEW TERR,HONG KONG
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1996年 / 23卷 / 08期
关键词
partition model; yttrium-90; radiation doses; hepatic rumours;
D O I
10.1007/BF01084369
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A uniform distribution of yttrium-90 (Y-90) microspheres throughout the entire liver has always been assumed for dose calculation in treating hepatic tumours. A simple mathematical model was formulated which allows estimation of the activities of a therapeutic dose of Y-90 microspheres partitioned between the lungs, the tumour and the normal liver, and hence the radiation doses to them. The doses to the tumour and normal liver were verified by intra-operative direct beta-probing. The percentage of activity shunted to the lung and the tumour-to-normal tissue ratio (T/N) were obtained from gamma scintigraphy using technetium-99m-labelled macroaggregated albumin (MAA) which simulates the Y-90 microspheres used in subsequent treatment. The intrahepatic activity was partitioned between the tumour and the normal liver based on the T/N and their masses determined from computerized tomography slices, The corresponding radiation doses were computed using the MIRD formula. The estimated radiation doses were correlated with the doses directly measured using a calibrated beta-probe at laparotomy by linear regression, The radiation doses to the tumour and the normal liver, estimated using the partition model, were close to that measured directly with coefficients of correlation for linear regression: 0.862 for the rumours and 0.804 for the normal liver compartment (P<0.001). The partition model permits a distinction between the radiation doses received by the tumour and the normal liver to be made and the doses thus estimated are close to the actual doses received, The optimal doses to the tumour and normal liver and hence the required quantity of Y-90 microspheres to be administered can be easily predetermined.
引用
收藏
页码:947 / 952
页数:6
相关论文
共 31 条
  • [1] ANDREWS JC, 1994, J NUCL MED, V35, P1637
  • [2] ARIEL IM, 1967, CANCER, V20, P793, DOI 10.1002/1097-0142(1967)20:5<793::AID-CNCR2820200534>3.0.CO
  • [3] 2-I
  • [5] TREATMENT OF ASYMPTOMATIC METASTATIC CANCER TO THE LIVER FROM PRIMARY COLON AND RECTAL-CANCER BY THE INTRA-ARTERIAL ADMINISTRATION OF CHEMOTHERAPY AND RADIOACTIVE ISOTOPES
    ARIEL, IM
    PADULA, G
    [J]. JOURNAL OF SURGICAL ONCOLOGY, 1982, 20 (03) : 151 - 156
  • [6] BLANCHARD RJW, 1989, J CAN ASSOC RADIOL, V40, P206
  • [7] BURTON MA, 1989, NUCL MED BIOL, V16, P495
  • [8] SELECTIVE INTERNAL RADIATION-THERAPY - DISTRIBUTION OF RADIATION IN THE LIVER
    BURTON, MA
    GRAY, BN
    KLEMP, PF
    KELLEHER, DK
    HARDY, N
    [J]. EUROPEAN JOURNAL OF CANCER & CLINICAL ONCOLOGY, 1989, 25 (10): : 1487 - 1491
  • [9] SELECTIVE INTERNAL RADIATION-THERAPY - VALIDATION OF INTRAOPERATIVE DOSIMETRY
    BURTON, MA
    GRAY, BN
    KELLEHER, DK
    KLEMP, PF
    [J]. RADIOLOGY, 1990, 175 (01) : 253 - 255
  • [10] FEINENDEGEN LE, 1994, J NUCL MED, V35, P1644