Diagnostic accuracy of point-of-care ultrasound for evaluation of early blood-induced joint changes: Comparison with MRI

被引:32
作者
Foppen, W. [1 ]
van der Schaaf, I. C. [1 ]
Beek, F. J. A. [1 ]
Mali, W. P. T. M. [1 ]
Fischer, K. [2 ,3 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, HP E-01-132,POB 85500, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Dept Hematol, Van Creveldklin, Utrecht, Netherlands
关键词
arthropathy; haemarthrosis; MRI; Sensitivity; Specificity; Ultrasound; EARLY ARTHROPATHY DETECTION; HEMOPHILIC ARTHROPATHY; MUSCULOSKELETAL ULTRASOUND; CHILDREN; TOOL;
D O I
10.1111/hae.13524
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Aim Recurrent joint bleeding is the hallmark of haemophilia. Synovial hypertrophy observed with Magnetic Resonance Imaging (MRI) is associated with an increased risk of future joint bleeding. The aim of this study was to investigate whether point-of-care ultrasound (POC-US) is an accurate alternative for MRI for the detection of early joint changes. Methods Results In this single centre diagnostic accuracy study, bilateral knees and ankles of haemophilia patients with no or minimal arthropathy on X-rays were scanned using POC-US and 3 Tesla MRI. POC-US was performed by 1 medical doctor, blinded for MRI, according to the "Haemophilia Early Arthropathy Detection with Ultrasound" (HEAD-US) protocol. MRIs were independently scored by 2 radiologists, blinded for clinical data and ultrasound results. Diagnostic accuracy parameters were calculated with 95% confidence intervals (CI). Knees and ankles of 24 haemophilia patients (96 joints), aged 18-34, were studied. Synovial hypertrophy on MRI was observed in 20% of joints. POC-US for synovial tissue was correct (overall accuracy) in 97% (CI: 91-99) with a positive predictive value of 94% (CI: 73-100) and a negative predictive value of 97% (CI: 91-100). The overall accuracy of POC-US for cartilage abnormalities was 91% (CI: 83-96) and for bone surface irregularities 97% (CI: 91-99). Conclusion POC-US could accurately assess synovial hypertrophy, bone surface irregularities and cartilage abnormalities in haemophilia patients with limited joint disease. As POC-US is an accurate and available alternative for MRI, it can be used for routine evaluation of early joint changes.
引用
收藏
页码:971 / 979
页数:9
相关论文
共 31 条
[1]   Home-delivered ultrasound monitoring for home treatment of haemarthrosis in haemophilia A [J].
Aznar, J. A. ;
Perez-Alenda, S. ;
Jaca, M. ;
Garcia-Dasi, M. ;
Vila, C. ;
Moret, A. ;
Querol, F. ;
Bonanad, S. .
HAEMOPHILIA, 2015, 21 (02) :E147-E150
[2]   Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD initiative [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Lijmer, JG ;
Moher, D ;
Rennie, D ;
de Vet, HCW .
RADIOLOGY, 2003, 226 (01) :24-28
[3]   Rapid musculoskeletal ultrasound for painful episodes in adult haemophilia patients [J].
Ceponis, A. ;
Wong-Sefidan, I. ;
Glass, C. S. ;
von Drygalski, A. .
HAEMOPHILIA, 2013, 19 (05) :790-798
[4]   A systematic review of MR imaging as a tool for evaluating haemophilic arthropathy in children [J].
Chan, M. W. ;
Leckie, A. ;
Xavier, F. ;
Uleryk, E. ;
Tadros, S. ;
Blanchette, V. ;
Doria, A. S. .
HAEMOPHILIA, 2013, 19 (06) :E324-E334
[5]   Magnetic resonance imaging in teenagers and young adults with limited haemophilic arthropathy: baseline results from a prospective study [J].
Den Uijl, I. E. M. ;
De Schepper, A. M. A. ;
Camerlinck, M. ;
Grobbee, D. E. ;
Fischer, K. .
HAEMOPHILIA, 2011, 17 (06) :926-930
[6]   Diagnostic Accuracy of Ultrasound for Assessment of Hemophilic Arthropathy: MRI Correlation [J].
Doria, Andrea S. ;
Keshava, Shyamkumar N. ;
Mohanta, Arun ;
Jarrin, Jose ;
Blanchette, Victor ;
Srivastava, Alok ;
Moineddin, Rahim ;
Kavitha, M. L. ;
Hilliard, Pamela ;
Poonnoose, Pradeep ;
Gibikote, Sridhar .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) :W336-W347
[7]  
Fischer K, 2015, J THROMB HAEMOST, V13, P601
[8]   Value of routine ultrasound in detecting early joint changes in children with haemophilia using the 'Haemophilia Early Arthropathy Detection with UltraSound' protocol [J].
Foppen, W. ;
Van Der Schaaf, I. C. ;
Fischer, K. .
HAEMOPHILIA, 2016, 22 (01) :121-125
[9]  
Foppen W, 2015, HAEMOPHILIA, V21, P41
[10]   The diagnostic accuracy of unenhanced MRI in the assessment of joint abnormalities in juvenile idiopathic arthritis [J].
Hemke, Robert ;
Kuijpers, Taco W. ;
van den Berg, J. Merlijn ;
van Veenendaal, Mira ;
Dolman, Koert M. ;
van Rossum, Marion A. J. ;
Maas, Mario .
EUROPEAN RADIOLOGY, 2013, 23 (07) :1998-2004