Intrauterine device and maternal copper metabolism during lactation

被引:10
|
作者
Cunha, ARC
Dorea, JG [1 ]
Cantuaria, AA
机构
[1] Univ Brasilia, Fac Ciencias Saude, Dept Obstet & Gynecol, BR-70910970 Brasilia, DF, Brazil
[2] Univ Brasilia, Fac Ciencias Saude, Dept Nutr, BR-70910970 Brasilia, DF, Brazil
关键词
copper; endometrium; IUD; breast milk; cerulopasmin;
D O I
10.1016/S0010-7824(00)00191-8
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The effects of intrautuerine device (IUD) on maternal copper (Cu) metabolism during breastfeeding was studied in 95 volunteer mothers who chose to use non-hormonal contraceptive methods. They were divided into two groups that were inserted with the IUD-Cu 380A (n = 33), IUD-Cu 200B (n = 29), and a third group that did not use any IUDs served as control (n = 33). Endometrial biopsies, blood, and milk samples were collected before (at 10 weeks postpartum) and 6 weeks after insertion of device for the determination of metabolites associated with copper metabolism, namely, serum ceruloplasmin, and copper concentrations in breast milk and endometrium. Endometrial copper concentration increased in women using IUDs, but was statistically significant (p = 0.001) only in the IUD-Cu 380A group. The increase in endometrial copper concentration did not affect serum ceruloplasmin or milk copper concentrations. (C) 2001 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:37 / 39
页数:3
相关论文
共 50 条
  • [1] COMPARISON OF PAIN LEVEL DURING AND AFTER INTRAUTERINE DEVICE INSERTION: LEVONORGESTREL-RELEASING INTRAUTERINE SYSTEM VERSUS THE COPPER T INTRAUTERINE DEVICE
    Cirstoiu, Monica
    Munteanu, Octavian
    Antoniac, Iulian
    Cirstoiu, Catalin
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2016, 15 (05): : 965 - 972
  • [2] Continuation and satisfaction with intrauterine copper device inserted during caesarean delivery
    de Albuquerque, Clarisse Uchoa
    Rios, Camila Elena Gomes Filgueiras
    Figueiredo, Elfie Tomaz
    Bruno, Zenilda Vieira
    Feitosa, Francisco Edson de Lucena
    Peixoto, Raquel Autran Coelho
    EUROPEAN JOURNAL OF CONTRACEPTION AND REPRODUCTIVE HEALTH CARE, 2021, 26 (06): : 486 - 490
  • [3] Retained Copper Intrauterine Device Fragment in Pregnancy: A Case Report
    Chin, Justin
    Lomiguen, Christine M.
    Hernandez, Haydee
    Kane, Amy
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (12)
  • [4] Copper accumulation in actinomyces druses during endometritis after Long-uerm use of an intrauterine contraceptive device
    Jonas, L
    Baguhl, F
    Wilken, HP
    Haas, HJ
    Nizze, H
    ULTRASTRUCTURAL PATHOLOGY, 2002, 26 (05) : 323 - 329
  • [5] Breakage of arm of Multiload intrauterine device during removal
    Mohanty, K.
    INTERNATIONAL JOURNAL OF STD & AIDS, 2009, 20 (07) : 512 - 514
  • [6] Characterization of copper in uterine fluids of patients who use the copper T-380A intrauterine device
    Arancibia, V
    Peña, C
    Allen, HE
    Lagos, G
    CLINICA CHIMICA ACTA, 2003, 332 (1-2) : 69 - 78
  • [7] Use of the copper intrauterine device in the management of secondary amenorrhea
    Vesce, F
    Jorizzo, G
    Bianciotto, A
    Gotti, G
    FERTILITY AND STERILITY, 2000, 73 (01) : 162 - 165
  • [8] Characterization of corrosion products on a copper-containing intrauterine device during storage at room temperature
    Bastidas, JM
    Simancas, T
    BIOMATERIALS, 1997, 18 (03) : 247 - 250
  • [9] Zinc and copper metabolism in pregnancy and lactation of adolescent women
    Afonso Maia, Patricia
    Figueiredo, Renata C. B.
    Silva Anastacio, Alexandra
    Porto da Silveira, Carmen Lucia
    Marino Donangelo, Carmen
    NUTRITION, 2007, 23 (03) : 248 - 253
  • [10] Comparison of uterine artery blood flow with levonorgestrel intrauterine system and copper intrauterine device
    Haliloglu, Berna
    Celik, Aygen
    Ilter, Erdin
    Bozkurt, Serpil
    Ozekici, Umit
    CONTRACEPTION, 2011, 83 (06) : 578 - 581