An electrochemical sensor for the determination of Cu(II) using a modified electrode with ferrocenyl crown ether compound by square wave anodic stripping voltammetry

被引:40
|
作者
Flores, Erick [1 ]
Pizarro, Jaime [1 ]
Godoy, Fernando [1 ]
Segura, Rodrigo [1 ]
Gomez, Alejandra [1 ]
Agurto, Nicolas [1 ]
Sepulveda, Pamela [2 ]
机构
[1] Univ Santiago Chile USACH, Dept Quim Mat, Fac Quim & Biol, Santiago 3363, Chile
[2] Univ Santiago Chile USACH, Fac Quim & Biol, CEDENNA, Santiago 3363, Chile
关键词
Macrocylic fragment; Ferrocenyl imine; Electrochemical sensor; Square wave anodic stripping voltammetry; Copper; ATOMIC-ABSORPTION-SPECTROMETRY; CLOUD POINT EXTRACTION; COPPER DETERMINATION; WATER SAMPLES; CADMIUM; LEAD; COMPLEXES; ZINC; CONTAMINATION; CHEMOSENSORS;
D O I
10.1016/j.snb.2017.05.058
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical sensor based on a glassy carbon electrode modified with ferrocenyl imine [(eta(5)-C5H4CH=N-4'-benzo-15-crown-5)Fe(eta(5)-C5H5)] (FcIB15C5) has been developed for the determination of Cu(II) using square wave anodic stripping voltammetry (SWASV). The metalloligand was synthesized from ferrocene-carboxaldehyde and 4'-aminobenzo-15-crown-5. The metalloligand FcIB15C5 was characterized by FT-IR, H-1 - C-13 NMR spectroscopies and mass spectrometry and was obtained as a single isolated isomer (E-configuration). The optimum conditions for the prepared electrode were as follows: BrittonRobinson buffer with pH = 6.0, FcIB15C5 concentration = 0.3 mM, accumulation potential (E-acc) = -0.8 V and accumulation time (t(acc)) = 90 s. A linear range was observed from 10 to 70 mu g L-1 with a limit of detection (LOD) of 0.11 mu g L-1. The proposed procedure was validated with TMDA-64.2 and CRM-TMDW certified reference materials, and it showed good accuracy and precision. The methodology was applied to a mining effluent and urine samples with satisfactory results. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 50 条
  • [41] A study of the determination of Cu(II) by anodic stripping voltammetry on a novel nylon/carbon fiber electrode
    Mylonakis, A
    Economou, A
    Fielden, PR
    Goddard, NJ
    Voulgaropoulos, A
    ELECTROANALYSIS, 2004, 16 (07) : 524 - 531
  • [42] Determination of lead and cadmium using a polycyclodextrin-modified carbon paste electrode with anodic stripping voltammetry
    Gabriela Roa
    M. T. Ramírez-Silva
    M. A. Romero-Romo
    Laura Galicia
    Analytical and Bioanalytical Chemistry, 2003, 377 : 763 - 769
  • [43] Determination of trace heavy metal ions by anodic stripping voltammetry using nanofibrillated cellulose modified electrode
    Zinoubi, K.
    Majdoub, H.
    Barhoumi, H.
    Boufi, S.
    Jaffrezic-Renault, N.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 : 70 - 77
  • [44] Determination of lead and cadmium using a polycyclodextrin-modified carbon paste electrode with anodic stripping voltammetry
    Roa, G
    Ramírez-Silva, MT
    Romero-Romo, MA
    Galicia, L
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (04) : 763 - 769
  • [45] Few-layer Binder Free Graphene Modified Mercury Film Electrode for Trace Metal Analysis by Square Wave Anodic Stripping Voltammetry
    Zbeda, Salma
    Pokpas, Keagan
    Titinchi, Salam
    Jahed, Nazeem
    Baker, Priscilla G.
    Iwuoha, Emmanuel I.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (09): : 11125 - 11141
  • [46] Simultaneous Determination of Trace Zinc(II) and Cadmium(II) by Differential Pulse Anodic Stripping Voltammetry Using a MWCNTs-NaDBS Modified Stannum Film Electrode
    Tian, Yun Qing
    Li, Nian Bing
    Luo, Hong Qun
    ELECTROANALYSIS, 2009, 21 (23) : 2584 - 2589
  • [47] Anodic stripping voltammetric determination of Hg(II) using poly xylenol orange film modified electrode
    Manikandan, Ramalingam
    Deepa, P. N.
    Narayanan, Sangilimuthu Sriman
    IONICS, 2019, 25 (03) : 1387 - 1394
  • [48] An electrochemical sensor based on green tea extract for detection of Cd(II) ions by differential pulse anodic stripping voltammetry
    Incebay, Hilal
    Aktepe, Leyla
    Leblebici, Zeliha
    SURFACES AND INTERFACES, 2020, 21
  • [49] Comparison of Different PLS Algorithms for Simultaneous Determination of Cd(II), Cu(II), Pb(II), and Zn(II) by Anodic Stripping Voltammetry at Bismuth Film Electrode
    Pinto, Licarion
    Lemos, Sherlan G.
    ELECTROANALYSIS, 2014, 26 (02) : 299 - 305
  • [50] Determination of Copper(II) and Cadmium(II) in Rice Samples by Anodic Stripping Square Wave Voltammetry Using Reduced Graphene Oxide/Polypyrrole Composite Modified Screen-printed Carbon Electrode
    Petsawi, Ploypailin
    Yaiwong, Patrawadee
    Laocharoensuk, Rawiwan
    Ounnunkad, Kontad
    CHIANG MAI JOURNAL OF SCIENCE, 2019, 46 (02): : 322 - 336