An electrochemical sensor for the determination of Cu(II) using a modified electrode with ferrocenyl crown ether compound by square wave anodic stripping voltammetry

被引:40
|
作者
Flores, Erick [1 ]
Pizarro, Jaime [1 ]
Godoy, Fernando [1 ]
Segura, Rodrigo [1 ]
Gomez, Alejandra [1 ]
Agurto, Nicolas [1 ]
Sepulveda, Pamela [2 ]
机构
[1] Univ Santiago Chile USACH, Dept Quim Mat, Fac Quim & Biol, Santiago 3363, Chile
[2] Univ Santiago Chile USACH, Fac Quim & Biol, CEDENNA, Santiago 3363, Chile
关键词
Macrocylic fragment; Ferrocenyl imine; Electrochemical sensor; Square wave anodic stripping voltammetry; Copper; ATOMIC-ABSORPTION-SPECTROMETRY; CLOUD POINT EXTRACTION; COPPER DETERMINATION; WATER SAMPLES; CADMIUM; LEAD; COMPLEXES; ZINC; CONTAMINATION; CHEMOSENSORS;
D O I
10.1016/j.snb.2017.05.058
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical sensor based on a glassy carbon electrode modified with ferrocenyl imine [(eta(5)-C5H4CH=N-4'-benzo-15-crown-5)Fe(eta(5)-C5H5)] (FcIB15C5) has been developed for the determination of Cu(II) using square wave anodic stripping voltammetry (SWASV). The metalloligand was synthesized from ferrocene-carboxaldehyde and 4'-aminobenzo-15-crown-5. The metalloligand FcIB15C5 was characterized by FT-IR, H-1 - C-13 NMR spectroscopies and mass spectrometry and was obtained as a single isolated isomer (E-configuration). The optimum conditions for the prepared electrode were as follows: BrittonRobinson buffer with pH = 6.0, FcIB15C5 concentration = 0.3 mM, accumulation potential (E-acc) = -0.8 V and accumulation time (t(acc)) = 90 s. A linear range was observed from 10 to 70 mu g L-1 with a limit of detection (LOD) of 0.11 mu g L-1. The proposed procedure was validated with TMDA-64.2 and CRM-TMDW certified reference materials, and it showed good accuracy and precision. The methodology was applied to a mining effluent and urine samples with satisfactory results. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 50 条
  • [21] Electrochemical Determination of Lead(II) in Environmental Waters Using a Sulfydryl Modified Covalent Organic Framework by Square Wave Anodic Stripping Voltammetry (SWASV)
    Wang, Rongyu
    Ji, Wenhua
    Huang, Luqi
    Guo, Lanping
    Wang, Xiao
    ANALYTICAL LETTERS, 2019, 52 (11) : 1757 - 1770
  • [22] Electrochemical determination of cadmium(II) at platinum electrode modified with kaolin by square wave voltammetry
    El Mhammedi, M. A.
    Achak, M.
    Hbid, M.
    Bakasse, M.
    Hbid, T.
    Chtaini, A.
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 170 (2-3) : 590 - 594
  • [23] Indirect electrochemical determination of ciprofloxacin by anodic stripping voltammetry of Cd(II) on graphene-modified electrode
    Shan, Jun
    Liu, Yong
    Li, Ruizhen
    Wu, Can
    Zhu, Lihua
    Zhang, Jingdong
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 738 : 123 - 129
  • [24] Square wave anodic stripping voltammetry of copper(II) at a MWCNT paste electrode modified with a tetracarbonylmolybdenum(0) nanocomposite
    Mohamad Idris Saidin
    Illyas Md Isa
    Mustaffa Ahmad
    Norhayati Hashim
    Azlan Kamari
    S. Ab Ghani
    Suyanta M. Si
    Microchimica Acta, 2016, 183 : 1441 - 1448
  • [25] SQUARE-WAVE ANODIC STRIPPING VOLTAMMETRY (SWASV) FOR THE DETERMINATION OF ECOTOXIC METALS, USING A BISMUTH-FILM ELECTRODE
    Anastasiadou, Z. D.
    Sipaki, I.
    Jannakoudakis, P. D.
    Girousi, S. T.
    ANALYTICAL LETTERS, 2011, 44 (05) : 761 - 777
  • [26] Simultaneous determination of lead and copper by anodic stripping voltammetry using a poly(L-glutamic acid) modified electrode
    Xie, Ning
    Ma, Wei
    Gao, Hui
    Sun, Dengming
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2017, 56 (02): : 238 - 242
  • [27] Analysis of trace nickel by square wave stripping voltammetry using chloropalladium(II) complex-modified MWCNTs paste electrode
    Saidin, Mohamad Idris
    Isa, Illyas Md
    Ahmad, Mustaffa
    Hashim, Norhayati
    Ab Ghani, Sulaiman
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 240 : 848 - 856
  • [28] Square Wave Anodic Stripping Voltammetry Applied to a Nano-Electrode for Trace Analysis of Pb(II) and Cd(II) Ions in Solution
    Scandurra, Antonino
    Mirabella, Salvo
    IEEE SENSORS JOURNAL, 2021, 21 (20) : 22134 - 22142
  • [29] CARBON PASTE ELECTRODE MODIFIED WITH Bi NANOPARTICLES - CARBON XEROGEL FOR Pb2+ DETERMINATION BY SQUARE WAVE ANODIC STRIPPING VOLTAMMETRY
    Deac, Aglaia Raluca
    Cotet, Liviu Cosmin
    Turdean, Graziella Liana
    Muresan, Liana Maria
    REVUE ROUMAINE DE CHIMIE, 2015, 60 (7-8) : 697 - 705
  • [30] Simultaneous determination of cadmium, lead and copper in chocolate samples by square wave anodic stripping voltammetry
    Silva, Larissa Pinto
    Campos, Naira Da Silva
    Lisboa, Thalles Pedrosa
    de Faria, Lucas Vinicius
    Matos, Maria Auxiliadora Costa
    Matos, Renato Camargo
    de Sousa, Rafael Arromba
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2021, 38 (03): : 418 - 426