Vault changes and pupillary responses to light in myopic and toric implantable collamer lens

被引:8
作者
Xiong, Ying [1 ]
Mao, Yingyan [2 ,3 ,4 ]
Li, Jing [1 ]
Wan, Xiuhua [2 ]
Li, Meng [2 ]
Zhang, Jingshang [2 ]
Wang, Jinda [2 ]
Sun, Xiuli [2 ]
机构
[1] Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Dept Ophthalmol, 1 Dongjiaomin Lane, Beijing 100000, Peoples R China
[2] Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing Inst Ophthalmol, Beijing, Peoples R China
[3] Beihang Univ, Beijing Adv Innovat Ctr Big Data Based Precis Med, Beijing, Peoples R China
[4] Capital Med Univ, Beijing Tongren Hosp, Beijing, Peoples R China
关键词
Implantable collamer lens; High myopia; Vault; Pupillary response; PHAKIC INTRAOCULAR-LENS; POSTERIOR CHAMBER LENS; FLUID-DYNAMICS; AQUEOUS-HUMOR; CONTACT-LENS; ACCOMMODATION; SIZE; MOVEMENT; MODERATE; ICL;
D O I
10.1186/s12886-021-02119-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Achieving an appropriate vault is the main concern after the implantation of Implantable Collamer Lens (ICLs) for surgical correction of high myopia. The vault will vary with time and optical parameters, such as accommodation and pupil size. This research is to evaluate the vault change in Myopic and Toric ICLs under different lighting conditions; and to analyze the relationship between vault changes and pupillary responses to light. Methods We enrolled and analyzed 68 eyes from 68 patients who were implanted with Myopic EVO ICLs; we also included 60 eyes from 60 patients who were implanted with Toric EVO ICLs. The anterior chamber depth, pupil size and the post-operative vault were evaluated, 1 week after the operation, using a Visante Optical Coherence Tomography (OCT) under different lighting conditions. For each eye that was assessed, we calculated the vault change, which is defined as the difference between vault under mesopic condition and photopic condition; and the rate of vault change, which is defined as the vault change divided by mesopic vault. Results No significant difference was noted with the anterior chamber depth between mesopic and photopic conditions in either group. A significant decrease in vault and pupil size was detected under photopic condition in both groups. We found no difference in vault change between Myopic and Toric EVO ICLs under different lighting conditions. Moreover, the rate of vault change had a significant decrease with increased mesopic vault (baseline value). Conclusions Too low a mesopic vault has a big rate of vault change, which may cause the contact of ICL with crystalline lens in photopic state; Too high a mesopic vault would constrict the posterior movement of pupil. The findings of the study suggest that, for patients with high or low vault, we should be more careful and must perform checks in different lighting conditions.
引用
收藏
页数:8
相关论文
共 21 条
  • [1] Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)
    Chen, Xun
    Miao, Huamao
    Naidu, Rajeev Krishnan
    Wang, Xiaoying
    Zhou, Xingtao
    [J]. BMC OPHTHALMOLOGY, 2016, 16
  • [2] Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eye
    Fujisawa, Kunitoshi
    Shimizu, Kimiya
    Uga, Shigekazu
    Suzuki, Masanobu
    Nagano, Koichi
    Murakami, Yuuki
    Goseki, Hiroko
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (01) : 114 - 122
  • [3] Static and dynamic crystalline lens accommodation evaluated using quantitative 3-D OCT
    Gambra, Enrique
    Ortiz, Sergio
    Perez-Merino, Pablo
    Gora, Michalina
    Wojtkowski, Maciej
    Marcos, Susana
    [J]. BIOMEDICAL OPTICS EXPRESS, 2013, 4 (09): : 1595 - 1609
  • [4] Dynamic Assessment of Light-Induced Vaulting Changes of Implantable Collamer Lens With Central Port by Swept-Source OCT: Pilot Study
    Gonzalez-Lopez, Felix
    Mompean, Blas
    Bilbao-Calabuig, Rafael
    Vila-Arteaga, Jorge
    Beltran, Jaime
    Baviera, Julio
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (03):
  • [5] Eight-Year Follow-up of Posterior Chamber Phakic Intraocular Lens Implantation for Moderate to High Myopia
    Igarashi, Akihito
    Shimizu, Kimiya
    Kamiya, Kazutaka
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (03) : 532 - 539
  • [6] Computational Study of Aqueous Humor Dynamics Assessing the Vault and the Pupil Diameter in Two Posterior-Chamber Phakic Lenses
    Ignacio Fernandez-Vigo, Jose
    Macarro-Merino, Ana
    Fernandez-Francos, Joaquin
    De-Pablo-Gomez-de-Liano, Lucia
    Maria Martinez-de-la-Casa, Jose
    Garcia-Feijoo, Julian
    Angel Fernandez-Vigo, Jose
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (11) : 4625 - 4631
  • [7] Vault Changes Caused by Light-Induced Pupil Constriction and Accommodation in Eyes With an Implantable Collamer Lens
    Kato, Sayaka
    Shimizu, Kimiya
    Igarashi, Akihito
    [J]. CORNEA, 2019, 38 (02) : 217 - 220
  • [8] Theoretical study on the need for laser iridotomy in an implantable collamer lens with a hole using computational fluid dynamics
    Kawamorita, T.
    Shimizu, K.
    Shoji, N.
    [J]. EYE, 2017, 31 (05) : 795 - 801
  • [9] Kawamorita T, 2016, GRAEF ARCH CLIN EXP, V254, P739, DOI 10.1007/s00417-016-3304-3
  • [10] Fluid dynamics simulation of aqueous humour in a posterior-chamber phakic intraocular lens with a central perforation
    Kawamorita, Takushi
    Uozato, Hiroshi
    Shimizu, Kimiya
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (06) : 935 - 939