A comparative study of MED-EL FMT attachment to the long process of the incus in intact middle ears and its attachment to disarticulated stapes head

被引:18
作者
Chen, Tao [1 ]
Ren, Liu-Jie [1 ]
Yin, Dong-Ming [1 ]
Li, Jia [1 ,3 ]
Yang, Lin [1 ,2 ]
Dai, Pei-Dong [1 ,2 ]
Zhang, Tian-Yu [1 ,2 ]
机构
[1] Fudan Univ, Eye & ENT Hosp, Fenyang Rd 83, Shanghai 200031, Peoples R China
[2] Fudan Univ, ENT Inst, Eye & ENT Hosp, Fenyang Rd 83, Shanghai 200031, Peoples R China
[3] Fudan Univ, Dept Aeronaut & Astronaut, Handan Rd 220, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金;
关键词
Active middle-ear implant; Floating mass transducer; Laser Doppler vibrometer; LP coupler; CliP coupler; Bell coupler; FLOATING MASS TRANSDUCER; CONDUCTIVE HEARING-LOSS; VIBRANT SOUNDBRIDGE; WINDOW VIBROPLASTY; IMPLANT; EXPERIENCE; FIXATION; OSSICLES; MOTIONS;
D O I
10.1016/j.heares.2017.06.006
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
The Vibrant Soundbridge (R) (VSB) active middle-ear implant provides an effective treatment for mild-to severe sensorineural hearing loss in the case of normal middle ear anatomy and mixed hearing loss in middle ear malformation. The VSB floating mass transducer (FMT), with proper couplers, can be installed on various structures of the ossicular chain, e.g., the short and long process of the incus, the stapes head, and the stapes footplate. A long process (LP) coupler is most commonly used for FMT attachment to the long process of the incus with intact ossicular chain, while CliP and Bell couplers are two standardized and reliable methods for FMT attachment to the stapes head with missing incus and malleus. However, the difference and relationship of the vibration properties among these three FMT couplers remain unclear. In the present study, the stapes footplate velocity responses of the LP, CliP, and Bell couplers have been investigated in eight fresh temporal bones (TBs) to evaluate the vibration properties of these three couplers. Normal and reconstructed middle ear transfer functions (METFs) were determined from laser Doppler vibrometer (LDV) measurements. A mastoidectomy and a posterior tympanotomy were performed to expose the ossicular chain. The METFs of the normal middle ear and middle ear with LP-FMT-coupler were compared under acoustic stimulation, thus the mass effect of the FMT with LP coupler was evaluated. Additional comparisons were made between the stapes footplate vibrations of the LP-FMT-coupler (with the intact ossicular chain at the long process of the incus), CliP-FMT-coupler and Bell-FMT-coupler on the stapes head (after incus and malleus removed) under active electromechanical stimulation. After the installation of CliP-FMT-coupler and Bell-FMT-coupler to the middle ear, the average velocity amplitude of the stapes footplate, comparing to the LP-FMT-coupler, was about 15 dB higher between 1 and 6 kHz, and 10 dB lower at about 0.5 kHz. Quantitatively, there was no significant difference between the CliP-FMT-coupler and Bell-FMT-coupler. According to our study, installation of CliP-FMT-coupler or Bell-FMT-coupler on the stapes head provides considerable improvement of the middle ear mechanical and functional responses, comparing with the LP-FMT-coupler in the temporal bone experiments. Moreover, the installation of the Bell-FMT-coupler to the stapes head produces essentially the same footplate velocity responses in comparison to the CliP-FMT-coupler. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:97 / 103
页数:7
相关论文
共 26 条
[1]   Experience With Vibroplasty Couplers at the Stapes Head and Footplate [J].
Beleites, Thomas ;
Neudert, Marcus ;
Beutner, Dirk ;
Huettenbrink, Karl-Bernd ;
Zahnert, Thomas .
OTOLOGY & NEUROTOLOGY, 2011, 32 (09) :1468-1472
[2]   Titanium Clip Ball Joint: A Partial Ossicular Reconstruction Prosthesis [J].
Beutner, Dirk ;
Luers, Jan Christoffer ;
Bornitz, Matthias ;
Zahnert, Thomas ;
Huttenbrink, Karl-Bernd .
OTOLOGY & NEUROTOLOGY, 2011, 32 (04) :646-649
[3]  
de Abajo J, 2013, OTOL NEUROTOL, V34, P1373, DOI 10.1097/MAO.0b013e3182a0044e
[4]   The effect of rocking stapes motions on the cochlear fluid flow and on the basilar membrane motion [J].
Edom, Elisabeth ;
Obrist, Dominik ;
Henniger, Rolf ;
Kleiser, Leonhard ;
Sim, Jae Hoon ;
Huber, Alexander M. .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2013, 134 (05) :3749-3758
[5]   Mass loading on the ossicles and middle ear function [J].
Gan, RZ ;
Dyer, RK ;
Wood, MW ;
Dormer, KJ .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2001, 110 (05) :478-485
[6]   A new implantable middle ear hearing device for mixed hearing loss: A feasibility study in human temporal bones [J].
Huber, Alexander M. ;
Ball, Geoffrey R. ;
Veraguth, Dorothe ;
Dillier, Norbert ;
Bodmer, Daniel ;
Sequeira, Damien .
OTOLOGY & NEUROTOLOGY, 2006, 27 (08) :1104-1109
[7]   A New Vibroplasty Coupling Technique as a Treatment for Conductive and Mixed Hearing Losses: A Report of 4 Cases [J].
Huber, Alexander M. ;
Mlynski, Robert ;
Mueller, Joachim ;
Dillier, Norbert ;
Holzmann, David ;
Wolframm, Mario D. ;
Hagen, Rudolf .
OTOLOGY & NEUROTOLOGY, 2012, 33 (04) :613-617
[8]   The Effects of Complex Stapes Motion on the Response of the Cochlea [J].
Huber, Alexander M. ;
Sequeira, Damien ;
Breuninger, Christian ;
Eiber, Albrecht .
OTOLOGY & NEUROTOLOGY, 2008, 29 (08) :1187-1192
[9]   TORP-Vibroplasty: A New Alternative for the Chronically Disabled Middle Ear [J].
Huetenbrink, Karl-Bernd ;
Zahnert, Thomas ;
Bornitz, Matthias ;
Beutner, Dirk .
OTOLOGY & NEUROTOLOGY, 2008, 29 (07) :965-971
[10]   Clip Vibroplasty: Experimental Evaluation and First Clinical Results [J].
Huettenbrink, Karl-Bernd ;
Beutner, Dirk ;
Bornitz, Matthias ;
Luers, Jan Christoffer ;
Zahnert, Thomas .
OTOLOGY & NEUROTOLOGY, 2011, 32 (04) :650-653