Predictors of Cardiac Implantable Electronic Device Artifact on Cardiac MRI: The Utility of a Device Related Score

被引:4
作者
Kocyigit, Duygu [1 ]
Abozeed, Mostafa [2 ,3 ,4 ]
Kwon, Deborah H. [1 ,2 ]
Flamm, Scott D. [2 ]
Wilkoff, Bruce L. [1 ]
Jellis, Christine L. [1 ,2 ]
机构
[1] Cleveland Clin, Dept Cardiovasc Med, Cleveland, OH 44106 USA
[2] Cleveland Clin, Dept Diagnost Radiol, Cleveland, OH 44106 USA
[3] Al Azhar Univ, Dept Radiol, Cairo, Egypt
[4] Univ Alabama Birmingham, Cardiopulm Imaging Div, Birmingham, AL USA
关键词
Cardiac implantable electronic device; Implantable cardioverter-defibrillator; Persistent pacemaker; Cardiac magnetic resonance imaging; Artifact; Image quality; PACEMAKERS; STATEMENT; SAFETY;
D O I
10.1016/j.hlc.2021.02.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose Cardiac magnetic resonance imaging (CMR) image quality can be degraded by artifact in patients with cardiac implantable electronic devices (CIED). We aimed to establish a clinical risk score, so patient selection for diagnostic CMR could be optimised. Methods In this retrospective cohort study, CMRs performed for clinical use in subjects with CIED from January 2016 to May 2019 were reviewed. Subject anthropometry, CIED generator/lead specifications and pre-scan chest X-ray (CXR) measurements were collected. Generator-related artifact size was measured on axial steady state free precession images. Interpretability of late gadolinium enhancement (LGE) imaging was performed based on a three-grade visual score attributed to each of 17 myocardial segments. Results Fifty-seven (57) patients (59 +/- 16 years, 74% male) fitted the inclusion criteria. Artifact precluded left ventricle (LV) evaluation (>5 segments) in 17 (30%). Artifact was more common with implantable cardioverter-defibrillators, related to generator volume, mass, height, width, thickness, and area, along with right ventricular (RV) lead length and diameter (all p<0.05). Artifact was associated with distance from generator to LV apex, generator to RV lead tip and shortest distance from generator to heart on CXR (all p<0.05). On multivariable regression modelling, RV lead diameter (OR 5.861, 95% CI 1.866-18.407, p=0.002) and distance from generator to LV apex (OR 0.693, 95% CI 0.511-0.940, p=0.019) were independent predictors of artifact. Multivariable predictors were used to develop Device Related CMR Artifact Prediction Score (DR-CAPS), where all patients with DR-CAPS=0 had fully interpretable LGE imaging. Conclusion Simple, readily available measures, such as lead characteristics and pre-scan CXR measures, can stratify patients via an artifact prediction score to optimise selection for diagnostic CMR.
引用
收藏
页码:1348 / 1355
页数:8
相关论文
共 17 条
[1]   Clinical impact of cardiovascular magnetic resonance with optimized myocardial scar detection in patients with cardiac implantable devices [J].
Bhuva, Anish N. ;
Kellman, Peter ;
Graham, Adam ;
Ramlall, Manish ;
Boubertakh, Redha ;
Feuchter, Patricia ;
Hawkins, Angela ;
Lowe, Martin ;
Lambiase, Pier D. ;
Sekhri, Neha ;
Schilling, Richard J. ;
Moon, James C. ;
Manisty, Charlotte H. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 279 :72-78
[2]   Cardiac magnetic resonance imaging at 1.5 T in patients with cardiac rhythm devices [J].
Buendia, Francisco ;
Cano, Oscar ;
Miguel Sanchez-Gomez, Juan ;
Igual, Begona ;
Osca, Joaquin ;
Jose Sancho-Tello, Maria ;
Olaguee, Jose ;
Salvador, Antonio .
EUROPACE, 2011, 13 (04) :533-538
[3]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[4]   The Safety of Cardiac and Thoracic Magnetic Resonance Imaging in Patients with Cardiac Implantable Electronic Devices [J].
Dandamudi, Sanjay ;
Collins, Jeremy D. ;
Carr, James C. ;
Mongkolwat, Pat ;
Rahsepar, Amir A. ;
Tomson, Todd T. ;
Verma, Nishant ;
Arora, Rishi ;
Chicos, Alex B. ;
Kim, Susan S. ;
Lin, Albert C. ;
Passman, Rod S. ;
Knight, Bradley P. .
ACADEMIC RADIOLOGY, 2016, 23 (12) :1498-1505
[5]   ACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance [J].
Harrington, Robert A. ;
Anderson, Jeffrey L. ;
Bates, Eric R. ;
Bridges, Charles R. ;
Eisenberg, Mark J. ;
Ferrari, Victor A. ;
Grines, Cindy L. ;
Hlatky, Mark A. ;
Jacobs, Alice K. ;
Kaul, Sanjay ;
Lichtenberg, Robert C. ;
Lindner, Jonathan R. ;
Moliterno, David J. ;
Mukherjee, Debabrata ;
Pohost, Gerald M. ;
Rosenson, Robert S. ;
Schofield, Richard S. ;
Shubrooks, Samuel J., Jr. ;
Stein, James H. ;
Tracy, Cynthia M. ;
Weitz, Howard H. ;
Wesley, Deborah J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (23) :2614-2662
[6]   Artefact-free late gadolinium enhancement imaging in patients with implanted cardiac devices using amodified broadband sequence: current strategies and results froma real-world patient cohort [J].
Hilbert, Sebastian ;
Weber, Alexander ;
Nehrke, Kay ;
Boernert, Peter ;
Schnackenburg, Bernhard ;
Oebel, Sabrina ;
Spampinato, Ricardo ;
Rogge, Cathleen ;
Richter, Sergio ;
Hindricks, Gerhard ;
Paetsch, Ingo ;
Jahnke, Cosima .
EUROPACE, 2018, 20 (05) :801-807
[7]   Cardiovascular magnetic resonance imaging in patients with cardiac implantable electronic devices: a device-dependent imaging strategy for improved image quality [J].
Hilbert, Sebastian ;
Jahnke, Cosima ;
Loebe, Susanne ;
Oebel, Sabrina ;
Weber, Alexander ;
Spampinato, Ricardo ;
Richter, Sergio ;
Doering, Michael ;
Bollmann, Andreas ;
Sommer, Philipp ;
Hindricks, Gerhard ;
Paetsch, Ingo .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (09) :1051-1061
[8]   2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices [J].
Indik, Julia H. ;
Rod Gimbel, J. ;
Abe, Haruhiko ;
Alkmim-Teixeira, Ricardo ;
Birgersdotter-Green, Ulrika ;
Clarke, Geoffrey D. ;
Dickfeld, Timm-Michael L. ;
Froelich, Jerry W. ;
Grant, Jonathan ;
Hayes, David L. ;
Heidbuchel, Hein ;
Idriss, Salim F. ;
Kanal, Emanuel ;
Lampert, Rachel ;
Machado, Christian E. ;
Mandrola, John M. ;
Nazarian, Saman ;
Patton, Kristen K. ;
Rozner, Marc A. ;
Russo, Robert J. ;
Shen, Win-Kuang ;
Shinbane, Jerold S. ;
Teo, Wee Siong ;
Uribe, William ;
Verma, Atul ;
Wilkoff, Bruce L. ;
Woodard, Pamela K. .
HEART RHYTHM, 2017, 14 (07) :E97-E153
[9]  
Kusumoto FM, 2019, HEARTRHYTHM, V16, P128
[10]   Impact of ICD Artifact Burden on Late Gadolinium Enhancement Cardiac MR Imaging in Patients Undergoing Ventricular Tachycardia Ablation [J].
Mesubi, Olurotimi ;
Ahmad, Ghada ;
Jeudy, Jean ;
Jimenez, Alejandro ;
Kuk, Richard ;
Saliaris, Anastasios ;
See, Vincent ;
Shorofsky, Stephen ;
Dickfeld, Timm .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (10) :1274-1283