Design of 4π High-Efficiency Directional Radiation Detector Based on Compton Scattering

被引:5
|
作者
Ghelman, Max [1 ,2 ]
Kopeika, Natan [2 ]
Rotman, Stanley [2 ]
Edvabsky, Tal [1 ]
Vax, Eran [1 ]
Osovizky, Alon [1 ,3 ]
机构
[1] Nucl Res Ctr, Elect & Control Labs, IL-84190 Beer Sheva, Negev, Israel
[2] Ben Gurion Univ Negev, Dept Elect & Comp Engn, IL-84105 Beer Sheva, Israel
[3] Rotem Ind Ltd, Hlth Phys Instrumentat Dept, IL-85339 Lehavim, Israel
关键词
Compton scattering; directional detector; scintillator; silicon photomultiplier (SiPM); IMAGE-RECONSTRUCTION METHOD; CAMERA; PERFORMANCE; TEMPERATURE; RESOLUTION; SYSTEM;
D O I
10.1109/TNS.2022.3159663
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Obtaining directional information is required in many applications such as nuclear homeland security, contamination mapping after a nuclear incident and radiological events, or during the decontamination work. However, many directional radiation detectors are based on directional shielding, made of lead or tungsten collimators, introducing two main drawbacks. The first is the size and weight, making those detectors too heavy and irrelevant for utilization in handheld devices, drone mapping, or space applications. The second drawback is the limited field of view (FOV), which requires multiple detectors to cover the whole required FOV or machinery to rotate the detector's narrow FOV detector. We propose a novel 4 pi directional detector based on a segmented hollow cubic detector, which uses the Compton effect interactions with no heavy collimators. The symmetrical cubical design provides both higher efficiency and 4 pi detection ability. Instead of the traditional two types of detectors (scatterer and absorber) structure, we use the same type of detector, based on Gd3Al2Ga3O12 (GAGG) (Ce) scintillator coupled to silicon photomultiplier. An additional advantage of the proposed detector is obtained by locating the photon sensors inside the detector, behind the scintillators, which improves the radiation hardness required for space applications. Furthermore, such an arrangement flattens the temperature variation across the detector, providing better gain stability. The main advantage of the proposed detector is an efficient 4 pi radiation detection for high-energy gamma rays without the use of heavy collimators.
引用
收藏
页码:832 / 839
页数:8
相关论文
共 50 条
  • [1] Design of 4π Directional Radiation Detector based on Compton Scattering Effect
    Max, Ghelman
    Natan, Kopeika
    Stenley, Rotman
    Tal, Edvabsky
    Eran, Vax
    Alon, Osovizky
    ANIMMA 2021 - ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS, 2021, 253
  • [2] 4π directional radiation detector based on Compton scattering with channel reduction method
    Ghelman, Max
    Kopeika, Natan
    Rotman, Stanley
    Davidov, Zohar
    Osovizky, Alon
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1072
  • [3] A HIGH-EFFICIENCY FOCUSING CHERENKOV RADIATION DETECTOR
    LEWIS, KP
    MORAN, MJ
    HALL, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (03): : 1988 - 1990
  • [4] HIGH-EFFICIENCY FET MICROWAVE DETECTOR DESIGN
    LUGLIO, J
    ISHII, TK
    MICROWAVE JOURNAL, 1990, 33 (12) : 93 - &
  • [5] Wide Energetic Response of 4π Directional Gamma Detector Based on Combination of Compton Scattering and Photoelectric Effect
    Ghelman, Max
    Kopeika, Natan
    Rotman, Stanley
    Ben David, Nadav
    Vax, Eran
    Osovizky, Alon
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2024, 71 (05) : 1072 - 1083
  • [6] High-efficiency directional backlight design for an automotive display
    Chen, Bo-Tsuen
    Pan, Jui-Wen
    APPLIED OPTICS, 2018, 57 (16) : 4386 - 4395
  • [7] A HIGH-EFFICIENCY 4-PI NEUTRON DETECTOR
    HOLMQVIST, B
    RAMSTROM, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 188 (01): : 153 - 157
  • [8] A HIGH-EFFICIENCY NEUTRON DETECTOR
    DUCKWORTH, JC
    MERRISON, AW
    WHITTAKER, A
    NATURE, 1950, 165 (4185) : 69 - 69
  • [9] A HIGH-EFFICIENCY FLAME DETECTOR
    NUNNIKHOVEN, R
    ZEITSCHRIFT FUR ANALYTISCHE CHEMIE FRESENIUS, 1968, 236 (APR): : 79 - +
  • [10] A high-efficiency Transition Radiation Detector for high-counting-rate environments
    Petrovici, M.
    Petris, M.
    Berceanu, I.
    Simion, V.
    Bartos, D.
    Catanescu, V.
    Herghelegiu, A.
    Magureanu, C.
    Moisa, D.
    Radu, A.
    Klein-Boesing, M.
    Wessels, J. P.
    Wilk, A.
    Andronic, A.
    Garabatos, C.
    Simon, R.
    Uhlig, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (03): : 961 - 966