Multi-electrode array for spectral bandwidth control

被引:0
作者
Champagne, J. [1 ]
Kastelik, J. -C. [1 ]
Dupont, S. [1 ]
机构
[1] Univ Lille, Univ Polytech Hauts De France, Cent Lille, IEMN,DOAE,ISEN,CNRS,UMR 8520, F-59313 Valenciennes, France
来源
FOURTEENTH SCHOOL ON ACOUSTO-OPTICS AND APPLICATIONS | 2019年 / 11210卷
关键词
Acousto-optic; Acousto-optical devices; Acousto-optical materials; Acousto-optic filter; Wavelength filtering devices; Birefringence; Polarization-selective devices; Spectral resolution; TUNABLE ACOUSTOOPTIC FILTERS;
D O I
10.1117/12.2541007
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Acousto-optical tunable filters (AOTFs) are well used for practical applications and are most often based on the classical anisotropic non-collinear configuration in tellurium dioxide crystals. Any product sheet of such a commercially available AOTF presents two main features: the tuning range and the spectral bandwidth Delta lambda. The spectral transmission bandwidth(1) is proportional to the ratio lambda(2)/(bW) where lambda is the optical wavelength, b the dispersive constant and W the length of the transducer. The dispersive constant b is a rapidly decreasing function of the wavelength in the blue visible spectrum. As for examples: for a one octave tuning range starting from 400 nm to 800 nm, the spectral bandwidth is multiplied by similar to 10. For a tuning range in the infrared band 1250-2500 nm, the spectral bandwidth is multiplied by similar to 4. We present the design of a filter operating in the visible region from 450 nm to 650 nm. A double anisotropic interaction(2) is considered allowing the simultaneous diffraction of the two optical modes propagating into the crystal by a single ultrasonic wave. A multi-electrode array of three identical consecutive electrodes Wi:1-3 = 3 mm is deposited on the transducer leading to a more precise control of the spectral bandwidth. The acousto-optic device has been fabricated by the AA-Opto company. With this component the spectral bandwidth is only multiplied by similar to 2 on from 400 nm to 650 nm.
引用
收藏
页数:11
相关论文
共 22 条
  • [1] Acousto-optic image processing
    Balakshy, Vladimir I.
    Kostyuk, Dmitry E.
    [J]. APPLIED OPTICS, 2009, 48 (07) : C24 - C32
  • [2] Study of the spectral bandwidth of a double-pass acousto-optic system
    Champagne, Justine
    Kastelik, Jean-Claude
    Dupont, Samuel
    Gazalet, Joseph
    [J]. APPLIED OPTICS, 2018, 57 (10) : C49 - C55
  • [3] Cheng L.-J, 1993, FIELD OBSERVATIONS U, V4
  • [4] CHENG LJ, 1995, P SOC PHOTO-OPT INS, V2496, P305, DOI 10.1117/12.211326
  • [5] Dieulangard A, 2014, NOUVELLES CONFIGURAT
  • [6] Spectral characterization of acousto-optic filters used in imaging spectroscopy
    Georgiev, G
    Glenar, DA
    Hillman, JJ
    [J]. APPLIED OPTICS, 2002, 41 (01) : 209 - 217
  • [7] Goutzoulis A. P., 1988, Design and fabrication of acousto-optic devices, DOI [10.1201/9781003210221, DOI 10.1201/9781003210221]
  • [8] Acousto-optic tunable filter using double interaction for sidelobe reduction
    Kastelik, Jean-Claude
    Benaissa, Hichem
    Dupont, Samuel
    Pommeray, Michel
    [J]. APPLIED OPTICS, 2009, 48 (07) : C4 - C10
  • [9] Machihin A, 2013, PHOTONICS LASERS MED, V2
  • [10] Double-AOTF-based aberration-free spectral imaging endoscopic system for biomedical applications
    Machikhin, Alexander
    Pozhar, Vitold
    [J]. JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2015, 8 (03)