摘要
PURPOSE. To study the morphology of the Lens "Coloboma" using the technique of ultrasound biomicroscopy. METHODS. We used the Paradigm 40 Ultrasound biomicroscope to study the morphology of the lens "Coloboma". RESULTS. Ultrasound biomicroscopy of the lens "Coloboma" revealed a greatly increased sphericity of the lens and the deficiency of zonules in the "colobomatous" area. CONCLUSIONS. Ultrasound biomicroscopy has helped in elucidating the pathology of the lens "Coloboma".
引用
收藏
页码:390 / 391
页数:2
相关论文
共 4 条
[1]   In vivo imaging of the human zonular apparatus with high-resolution ultrasound biomicroscopy [J].
Ludwig, K ;
Wegscheider, E ;
Hoops, JP ;
Kampik, A .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1999, 237 (05) :361-371
[2]   Ocular colobomata [J].
Onwochei, BC ;
Simon, JW ;
Bateman, JB ;
Couture, KC ;
Mir, E .
SURVEY OF OPHTHALMOLOGY, 2000, 45 (03) :175-194
[3]   Imaging zonular abnormalities using ultrasound biomicroscopy [J].
Pavlin, CJ ;
Buys, YM ;
Pathmanathan, T .
ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (07) :854-857
[4]  