A Novel Method for Estimation of Femoral Neck Bone Mineral Density Using Forearm Images from Peripheral Cone Beam Computed Tomography

被引:3
作者
Jeong, Kwanmoon [1 ,2 ]
Ko, Hoon [1 ,2 ]
Lee, Chang-Hoon [2 ,3 ]
Lee, Myeung Su [2 ,3 ]
Yoon, Kwon-Ha [2 ,4 ]
Lee, Jinseok [1 ,2 ]
机构
[1] Wonkwang Univ, Sch Med, Dept Biomed Engn, 460 Iksandeaero, Iksan 570749, Jeonbuk, South Korea
[2] Wonkwang Univ, Imaging Sci Based Lung & Bone Dis Res Ctr, 460 Iksandeaero, Iksan 570749, Jeonbuk, South Korea
[3] Wonkwang Univ, Sch Med, Dept Rheumatol Internal Med, 460 Iksandeaero, Iksan 570749, Jeonbuk, South Korea
[4] Wonkwang Univ, Sch Med, Dept Radiol, 460 Iksandeaero, Iksan 570749, Jeonbuk, South Korea
来源
APPLIED SCIENCES-BASEL | 2016年 / 6卷 / 04期
关键词
cone beam computed tomography (CBCT); cortical bone; forearm; femoral neck; correlation; linear transformation; OSTEOPOROSIS; FRACTURE; WOMEN; DENSITOMETRY; ASSOCIATION; PREDICTION; DIAGNOSIS; ADULTS; MEN;
D O I
10.3390/app6040113
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The main goal of osteoporosis treatment is prevention of osteoporosis-induced bone fracture. Dual-energy X-ray absorptiometry (DXA) and quantitative computed tomographic imaging (QCT) are widely used for assessment of bone mineral density (BMD). However, they have limitations in patients with special conditions. This study evaluated a method for diagnosis of osteoporosis using peripheral cone beam computed tomography (CBCT) to estimate BMD. We investigated the correlation between the ratio of cortical and total bone areas of the forearm and femoral neck BMD. Based on the correlation, we established a linear transformation between the ratio and femoral neck BMD. We obtained forearm images using CBCT and femoral neck BMDs using dual-energy X-ray absorptiometry (DXA) for 23 subjects. We first calculated the ratio of the cortical to the total bone area in the forearm from the CBCT images, and investigated the relationship with the femoral neck BMDs obtained from DXA. Based on this relationship, we further investigated the optimal forearm region to provide the highest correlation coefficient. We used the optimized forearm region to establish a linear transformation of the form to estimate femoral neck BMD from the calculated ratio. We observed the correlation factor of r = 0.857 (root mean square error = 0.056435 g/cm(2); mean absolute percentage error = 4.5105%) between femoral neck BMD and the ratio of the cortical and total bone areas. The strongest correlation was observed for the average ratios of the mid-shaft regions of the ulna and radius. Our results suggest that femoral neck BMD can be estimated from forearm CBCT images and may be useful for screening osteoporosis, with patients in a convenient sitting position. We believe that peripheral CBCT image-based BMD estimation may have significant preventative value for early osteoporosis treatment and management.
引用
收藏
页数:12
相关论文
共 32 条
[1]   RELEVANCE OF OSTEOPOROSIS IN WOMEN WITH FRACTURE OF THE FEMORAL-NECK [J].
AITKEN, JM .
BMJ-BRITISH MEDICAL JOURNAL, 1984, 288 (6417) :597-601
[2]  
[Anonymous], POVERTY GENDER MIGRA
[3]   Conventional Multi-Slice Computed Tomography (CT) and Cone-Beam CT (CBCT) for Computer-Assisted Implant Placement. Part I: Relationship of Radiographic Gray Density and Implant Stability [J].
Arisan, Volkan ;
Karabuda, Zihni Cuneyt ;
Avsever, Hakan ;
Ozdemir, Tayfun .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (06) :893-906
[4]   Osteoporosis prediction from the mandible using cone-beam computed tomography [J].
Barngkgei, Imad ;
Al Haffar, Iyad ;
Khattab, Razan .
IMAGING SCIENCE IN DENTISTRY, 2014, 44 (04) :263-271
[5]   Proximal femoral structure and the prediction of hip fracture in men: A large prospective study using QCT [J].
Black, Dennis M. ;
Bouxsein, Mary L. ;
Marshall, Lynn M. ;
Cummings, Steven R. ;
Lang, Thomas F. ;
Cauley, Jane A. ;
Ensrud, Kristine E. ;
Nielson, Carrie M. ;
Orwoll, Eric S. .
JOURNAL OF BONE AND MINERAL RESEARCH, 2008, 23 (08) :1326-1333
[6]   Bone densitometry and the diagnosis of osteoporosis [J].
Blake, GM ;
Fogelman, I .
SEMINARS IN NUCLEAR MEDICINE, 2001, 31 (01) :69-81
[7]   Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysis [J].
Buie, Helen R. ;
Campbell, Graeme M. ;
Klinck, R. Joshua ;
MacNeil, Joshua A. ;
Boyd, Steven K. .
BONE, 2007, 41 (04) :505-515
[8]   Reproducibility of direct quantitative measures of cortical bone microarchitecture of the distal radius and tibia by HR-pQCT [J].
Burghardt, Andrew J. ;
Buie, Helen R. ;
Laib, Andres ;
Majumdar, Sharmila ;
Boyd, Steven K. .
BONE, 2010, 47 (03) :519-528
[9]   CONE BEAM CT: NON-DENTAL APPLICATIONS [J].
Casselman, J. W. ;
Gieraerts, K. ;
Volders, D. ;
Delanote, J. ;
Mermuys, K. ;
De Foer, B. ;
Swennen, G. .
JBR-BTR, 2013, 96 (06) :333-353
[10]   Cone-beam volume CT mammographic imaging: feasibility study [J].
Chen, BA ;
Ning, RL .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :655-664