Virus Sensitivity Index of UV disinfection

被引:9
|
作者
Tang, Walter Z. [1 ]
Sillanpaa, Mika [2 ]
机构
[1] Florida Int Univ, Dept Civil & Environm Engn, Miami, FL 33174 USA
[2] Lappeenranta Univ Technol, Fac Green Chem, Lappeenranta 53850, Finland
基金
美国国家科学基金会;
关键词
Virus Sensitivity Index (VSI); UV disinfection fluence equations; validation and prediction of virus inactivation rate constants; MS2-phage as a reference virus; COMPARATIVE INACTIVATION; ULTRAVIOLET-IRRADIATION; FELINE CALICIVIRUS; WATER; LIGHT; MICROORGANISMS; RADIATION; PHOTOREACTIVATION; BACTERIOPHAGES; ADENOVIRUSES;
D O I
10.1080/09593330.2014.994040
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new concept of Virus Sensitivity Index (VSI) is defined as the ratio between the first-order inactivation rate constant of a virus, k(i), and that of MS2-phage during UV disinfection, k(r). MS2-phage is chosen as the reference virus because it is recommended as a virus indicator during UV reactor design and validation by the US Environmental Protection Agency. VSI has wide applications in research, design, and validation of UV disinfection systems. For example, it can be used to rank the UV disinfection sensitivity of viruses in reference to MS2-phage. There are four major steps in deriving the equation between H-i/H-r and 1/VSI. First, the first-order inactivation rate constants are determined by regression analysis between Log I and fluence required. Second, the inactivation rate constants of MS2-phage are statistically analysed at 3, 4, 5, and 6 Log I levels. Third, different VSI values are obtained from the k(i) of different viruses dividing by the k(r) of MS2-phage. Fourth, correlation between H-i/H-r and 1/VSI is analysed by using linear, quadratic, and cubic models. As expected from the theoretical analysis, a linear relationship adequately correlates H-i/H-r and 1/VSI without an intercept. VSI is used to quantitatively predict the UV fluence required for any virus at any log inactivation (Log I). Four equations were developed at 3, 4, 5, and 6 Log I. These equations have been validated using external data which are not used for the virus development. At Log I less than 3, the equation tends to under-predict the required fluence at both low Log I such as 1 and 2 Log I. At Log I greater than 3 Log I, the equation tends to over-predict the fluence required. The reasons for these may very likely be due to the shoulder at the beginning and the tailing at the end of the collimated beam test experiments. At 3 Log I, the error percentage is less than 6%. The VSI is also used to predict inactivation rate constants under two different UV disinfection scenarios such as under sunlight and different virus aggregates. The correlation analysis shows that viruses will be about 40% more sensitive to sunlight than to UV254. On the other hand, virus size of 500 nm will reduce their VSI by 10%. This is the first attempt to use VSI to predict the required fluence at any given Log I. The equation can be used to quantitatively evaluate other parameters influencing UV disinfection. These factors include environmental species, antibiotic-resistant bacteria or genes, photo and dark repair, water quality such as suspended solids, and UV transmittance.
引用
收藏
页码:1464 / 1475
页数:12
相关论文
共 50 条
  • [41] UV-LED disinfection of Coronavirus: Wavelength effect
    Gerchman, Yoram
    Mamane, Hadas
    Friedman, Nehemya
    Mandelboim, Michal
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 2020, 212
  • [42] Disinfection of Swimming Pool Water by UV Irradiation and Ozonation
    Semenov, A. A.
    Sakhno, T. V.
    JOURNAL OF WATER CHEMISTRY AND TECHNOLOGY, 2021, 43 (06) : 491 - 496
  • [43] Disinfection of Swimming Pool Water by UV Irradiation and Ozonation
    A. A. Semenov
    T. V. Sakhno
    Journal of Water Chemistry and Technology, 2021, 43 : 491 - 496
  • [44] Comparison of Legionella pneumophila and Pseudomonas fluorescens Quantification Methods for Assessing UV LED Disinfection
    de Larrea, Jaser Lara
    MacIsaac, Sean A.
    Rauch, Kyle D.
    Stoddart, Amina K.
    Gagnon, Graham A.
    ACS ES&T WATER, 2023, 3 (11): : 3667 - 3675
  • [45] The UV Dose Used for Disinfection of Drinking Water in Sweden Inadequately Inactivates Enteric Virus with Double-Stranded Genomes
    Saguti, Fredy
    Churqui, Marianela Patzi
    Kjellberg, Inger
    Wang, Hao
    Ottoson, Jakob
    Paul, Catherine
    Bergstedt, Olof
    Norder, Helene
    Nystrom, Kristina
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (14)
  • [46] Sanitizing agents for virus inactivation and disinfection
    Lin, Qianyu
    Lim, Jason Y. C.
    Xue, Kun
    Yew, Pek Yin Michelle
    Owh, Cally
    Chee, Pei Lin
    Loh, Xian Jun
    VIEW, 2020, 1 (02)
  • [47] Treating disinfection byproducts with UV or solar irradiation and in UV advanced oxidation processes: A review
    Lei, Xin
    Lei, Yu
    Zhang, Xinran
    Yang, Xin
    JOURNAL OF HAZARDOUS MATERIALS, 2021, 408
  • [48] Effect of single and combined exposures to UV-C and UV-A LEDs on the inactivation of Klebsiella pneumoniae and Escherichia coli in water disinfection
    Galezzo, Maria-Angelica
    Susa, Manuel Rodriguez
    JOURNAL OF WATER SANITATION AND HYGIENE FOR DEVELOPMENT, 2021, 11 (06) : 1071 - 1082
  • [49] Preliminary investigation on safety of post-UV disinfection of wastewater: bio-stability in laboratory-scale simulated reuse water pipelines
    Guo, Meiting
    Hu, Hongying
    Liu, Wenjun
    DESALINATION, 2009, 239 (1-3) : 22 - 28
  • [50] Surface Disinfection Systems with UV-C Lamps - Verification Measurements and Design Procedure Proposal
    Wisniewski, Andrzej
    Skarzynski, Krzysztof
    Pracki, Piotr
    Krupinski, Rafal
    Wolska, Agnieszka
    Wiselka, Mariusz
    Pawlak, Andrzej
    LEUKOS, 2025, 21 (02) : 125 - 140