Virus Sensitivity Index of UV disinfection

被引:9
|
作者
Tang, Walter Z. [1 ]
Sillanpaa, Mika [2 ]
机构
[1] Florida Int Univ, Dept Civil & Environm Engn, Miami, FL 33174 USA
[2] Lappeenranta Univ Technol, Fac Green Chem, Lappeenranta 53850, Finland
基金
美国国家科学基金会;
关键词
Virus Sensitivity Index (VSI); UV disinfection fluence equations; validation and prediction of virus inactivation rate constants; MS2-phage as a reference virus; COMPARATIVE INACTIVATION; ULTRAVIOLET-IRRADIATION; FELINE CALICIVIRUS; WATER; LIGHT; MICROORGANISMS; RADIATION; PHOTOREACTIVATION; BACTERIOPHAGES; ADENOVIRUSES;
D O I
10.1080/09593330.2014.994040
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new concept of Virus Sensitivity Index (VSI) is defined as the ratio between the first-order inactivation rate constant of a virus, k(i), and that of MS2-phage during UV disinfection, k(r). MS2-phage is chosen as the reference virus because it is recommended as a virus indicator during UV reactor design and validation by the US Environmental Protection Agency. VSI has wide applications in research, design, and validation of UV disinfection systems. For example, it can be used to rank the UV disinfection sensitivity of viruses in reference to MS2-phage. There are four major steps in deriving the equation between H-i/H-r and 1/VSI. First, the first-order inactivation rate constants are determined by regression analysis between Log I and fluence required. Second, the inactivation rate constants of MS2-phage are statistically analysed at 3, 4, 5, and 6 Log I levels. Third, different VSI values are obtained from the k(i) of different viruses dividing by the k(r) of MS2-phage. Fourth, correlation between H-i/H-r and 1/VSI is analysed by using linear, quadratic, and cubic models. As expected from the theoretical analysis, a linear relationship adequately correlates H-i/H-r and 1/VSI without an intercept. VSI is used to quantitatively predict the UV fluence required for any virus at any log inactivation (Log I). Four equations were developed at 3, 4, 5, and 6 Log I. These equations have been validated using external data which are not used for the virus development. At Log I less than 3, the equation tends to under-predict the required fluence at both low Log I such as 1 and 2 Log I. At Log I greater than 3 Log I, the equation tends to over-predict the fluence required. The reasons for these may very likely be due to the shoulder at the beginning and the tailing at the end of the collimated beam test experiments. At 3 Log I, the error percentage is less than 6%. The VSI is also used to predict inactivation rate constants under two different UV disinfection scenarios such as under sunlight and different virus aggregates. The correlation analysis shows that viruses will be about 40% more sensitive to sunlight than to UV254. On the other hand, virus size of 500 nm will reduce their VSI by 10%. This is the first attempt to use VSI to predict the required fluence at any given Log I. The equation can be used to quantitatively evaluate other parameters influencing UV disinfection. These factors include environmental species, antibiotic-resistant bacteria or genes, photo and dark repair, water quality such as suspended solids, and UV transmittance.
引用
收藏
页码:1464 / 1475
页数:12
相关论文
共 50 条
  • [21] E-coli and bacteriophage MS2 disinfection by UV, ozone and the combined UV and ozone processes
    Fang, Jingyun
    Liu, Huiling
    Shang, Chii
    Zeng, Minzhen
    Ni, Mengling
    Liu, Wei
    FRONTIERS OF ENVIRONMENTAL SCIENCE & ENGINEERING, 2014, 8 (04) : 547 - 552
  • [22] Modelling of reactivation after UV disinfection:: Effect of UV-C dose on subsequent photoreactivation and dark repair
    Sanz, E. Nebot
    Davila, I. Salcedo
    Balao, J. A. Andrade
    Quiroga Alonso, J. M.
    WATER RESEARCH, 2007, 41 (14) : 3141 - 3151
  • [23] Comparison of UV-LED and low pressure UV for water disinfection: Photoreactivation and dark repair of Escherichia coli
    Li, Guo-Qiang
    Wang, Wen-Long
    Huo, Zheng-Yang
    Lu, Yun
    Hu, Hong-Ying
    WATER RESEARCH, 2017, 126 : 134 - 143
  • [24] UV Disinfection of Wastewater and Combined Sewer Overflows
    Gibson, John
    Drake, Jennifer
    Karney, Bryan
    ULTRAVIOLET LIGHT IN HUMAN HEALTH, DISEASES AND ENVIRONMENT, 2017, 996 : 267 - 275
  • [25] Lightweight UV-C disinfection system
    She, Rosemary C.
    Chen, Dongyu
    Pak, Pil
    Armani, Deniz K.
    Schubert, Andreas
    Armani, Andrea M.
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (08): : 4326 - 4332
  • [26] An IoT Approach for Monitoring UV Disinfection Robots
    McGinn, Conor
    Bourke, Eamonn
    Cullinan, Michael F.
    2021 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2021, : 3056 - 3060
  • [27] Evaluation of DNA damage reversal during medium-pressure UV disinfection
    Poepping, Christopher
    Beck, Sara E.
    Wright, Harold
    Linden, Karl G.
    WATER RESEARCH, 2014, 56 : 181 - 189
  • [28] Time dose reciprocity in UV disinfection of water
    Sommer, R
    Haider, T
    Cabaj, A
    Pribil, W
    Lhotsky, M
    WATER SCIENCE AND TECHNOLOGY, 1998, 38 (12) : 145 - 150
  • [29] Optimized Coverage Planning for UV Surface Disinfection
    Marques, Joao Marcos Correia
    Ramalingam, Ramya
    Pan, Zherong
    Hauser, Kris
    2021 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA 2021), 2021, : 9731 - 9737
  • [30] Photoreactivation of fungal spores in water following UV disinfection and their control using UV-based advanced oxidation processes
    Wen, Gang
    Deng, Xiaoli
    Wan, Qiqi
    Xu, Xiangqian
    Huang, Tinglin
    WATER RESEARCH, 2019, 148 : 1 - 9