Complication of an interbody biopolymer graft extruded orally after anterior cervical discectomy and fusion

被引:5
作者
Lin, TJ [1 ]
Huang, FC [1 ]
Chang, CK [1 ]
机构
[1] Mackay Mem Hosp, Tamshui Branch, Dept Surg, Div Neurosurg, Taipei, Taiwan
关键词
BOP graft; cervical discectomy; cervical myelopathy;
D O I
10.1016/S0967-5868(03)00162-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Graft extrusion is a dilemma that follows anterior cervical discectomy. We report on a case of an extrusion of a biocompatible osteoconductive polymer (BOP) graft extruded orally after anterior cervical discectomy and fusion. This case highlights the potential dangers in slipped or dislodged grafts and stresses the importance of investigation of patients whose symptoms might be attributable to graft extrusion. Furthermore, all dislodged implants should be removed to prevent further complications. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:629 / 632
页数:4
相关论文
共 9 条